1. Вступ
The OWON XDS2102A is a 2-channel, 12-bit high-resolution digital oscilloscope designed for precise signal analysis. It features a 100MHz bandwidth, 1GS/s real-time sample rate, and a 20M record length, making it suitable for various measurement applications. The device offers a 55,000 wfms/s waveform refresh rate for capturing transient events and includes multi-trigger and serial bus decoding functions (SPI, I2C, RS232, CAN).
2. Інформація про безпеку
Before operating the OWON XDS2102A oscilloscope, please read and understand all safety instructions. Failure to follow these instructions may result in injury or damage to the instrument. Always connect the instrument to a properly grounded power source. Do not operate the device in wet or damp conditions. Ensure proper ventilation to prevent overheating. Refer all servicing to qualified personnel.
3. Вміст упаковки
Перевірте, чи всі перелічені нижче предмети присутні у вашій упаковці:
- OWON XDS2102A Digital Oscilloscope
- Шнур живлення (x1)
- CD-ROM (x1)
- Короткий посібник (x1)
- USB -кабель (x1)
- Щупи осцилографа (x2)
- Probe Adjustment Tool (x1)
4. Продукт закінчивсяview
The OWON XDS2102A features an intuitive front panel layout and a range of connectivity options.
4.1 Передня панель
The front panel includes an 8-inch 800x600 high-resolution LCD for waveform display, along with various control buttons and knobs for instrument operation.

This image displays the OWON XDS2102A digital oscilloscope from a front-right angle. The device features an 8-inch color LCD screen showing two waveforms: a yellow sine wave and a blue square wave. The front panel is equipped with numerous control knobs and buttons for various functions, including vertical and horizontal adjustments, triggering, and menu navigation. Input connectors for channels CH1, CH2, and EXT Trig are visible at the bottom right. A USB host port is located below the screen.
Ключові елементи керування включають:
- Multipurpose Knob: For menu navigation and parameter adjustment.
- Функціональні кнопки: Such as Menu Off, Run/Stop, Single, Acquire, Autoset, Utility, Cursor, Save, Display, Help, Math.
- Вертикальні елементи керування: Position and Scale knobs for CH1 and CH2.
- Горизонтальні елементи керування: Position and Scale knobs for time base adjustment.
- Вхідні роз'єми: BNC connectors for CH1, CH2, and EXT Trig.
- Хост-порт USB: For data storage and firmware updates.
- Кнопка живлення: Щоб увімкнути або вимкнути пристрій.
4.2 Задня панель
The rear panel provides additional connectivity:
- Порт VGA: For external display connection, useful for presentations or larger viewінж.
- Порт LAN: Для підключення до мережі та дистанційного керування.
- Порт AUX: Auxiliary output.
- Порт USB-пристрою: Для підключення до комп'ютера.
- USB Port for PictBridge: For direct printing to compatible printers.
5. Налаштування
Follow these steps to set up your oscilloscope:
- Підключення живлення: Connect the provided power cord to the oscilloscope's power input and then to a grounded AC power outlet.
- Підключення зонда: Connect the oscilloscope probes to the CH1 and/or CH2 BNC input connectors. Ensure the probe's ground clip is securely connected to the circuit's ground.
- Компенсація зонда: For accurate measurements, compensate your probes. Connect the probe tip to the oscilloscope's probe compensation output (usually a square wave signal) and the ground clip to the ground terminal. Adjust the trimmer on the probe until the square wave displayed on the screen has flat tops and bottoms without overshoot or undershoot.
- Увімкнення: Натисніть кнопку живлення на передній панелі, щоб увімкнути осцилограф.
6. Інструкція з експлуатації
This section covers basic operation of the OWON XDS2102A oscilloscope.
6.1 Основні вимірювання
- Autoset: Натисніть Автонабір button to automatically adjust the vertical, horizontal, and trigger settings for a stable display of most signals.
- Vertical Scale and Position: Використовуйте масштаб knobs for CH1 and CH2 to adjust the vertical sensitivity (Volts/division). Use the Позиція knobs to move the waveform vertically on the screen.
- Horizontal Scale and Position: Use the horizontal масштаб knob to adjust the time base (seconds/division). Use the horizontal Позиція ручку для переміщення форми хвилі по горизонталі.
6.2 Запуск
Triggering stabilizes repetitive waveforms and captures single-shot events.
- Режим спуску: The XDS2102A supports various trigger modes. The default is typically Edge trigger.
- Джерело тригера: Select the input channel (CH1, CH2, EXT Trig) or AC Line as the trigger source.
- Trigger Coupling: Options include DC, AC, Noise Reject, HF Reject, LF Reject.
- Trigger Slope: Choose between rising edge, falling edge, or both.
- Рівень запуску: Відрегулюйте ручку рівня запуску, щоб встановити гучністьtagпоріг, при якому відбувається спрацьовування.
6.3 Bus Decoding
The oscilloscope supports decoding for common serial bus protocols.
- Access the bus decoding function through the menu.
- Select the desired protocol (SPI, I2C, RS232, CAN).
- Configure the relevant parameters for the chosen bus, such as clock source, data source, and thresholds.
7. Технічне обслуговування
Правильне обслуговування забезпечує довговічність та точність вашого осцилографа.
- Прибирання: Use a soft, dry cloth to clean the exterior of the instrument. For stubborn dirt, use a cloth lightly dampened with water or a mild detergent. Do not use abrasive cleaners or solvents.
- Догляд за зондом: Handle probes carefully. Avoid bending the probe cable sharply. Store probes in a clean, dry environment.
- Зберігання: Коли осцилограф не використовується, зберігайте його в прохолодному, сухому місці, подалі від прямих сонячних променів та екстремальних температур.
8. Вирішення проблем
If you encounter issues with your OWON XDS2102A, refer to the following common troubleshooting tips:
- Немає живлення: Ensure the power cord is securely connected to both the oscilloscope and a working power outlet. Check the power switch position.
- Сигнал не відображається: Verify that the input signal is connected correctly to the BNC input. Check probe connections and compensation. Adjust vertical scale and position. Ensure the trigger level is set appropriately. Try pressing the Автонабір кнопку.
- Спотворена форма хвилі: Check probe compensation. Ensure the input signal amplitude does not exceed the oscilloscope's input range. Verify proper grounding.
- Нестабільна форма хвилі: Adjust trigger settings (source, level, slope, mode) to achieve a stable display.
Якщо проблеми не зникнуть, зверніться по допомогу до служби підтримки клієнтів.
9. Технічні характеристики
| Особливість | Специфікація |
|---|---|
| Модель | XDS2102A |
| Канали | 2 |
| Пропускна здатність | 100 МГц |
| Sample Rate | 1 Г/с (у режимі реального часу) |
| роздільна здатність | 12-розрядний АЦП |
| Довжина запису | 20 мільйон балів |
| Частота оновлення сигналу | 55,000 XNUMX wfms/s |
| Вертикальна чутливість | 1 мВ/поділ - 10 В/поділ |
| Дисплей | 8-inch LCD, 800 x 600 resolution |
| Інтерфейси | USB Host, USB Device, USB for PictBridge, LAN, AUX, VGA |
| Розміри (Д x Ш x В) | 13.39 x 7.09 x 3.54 дюймів |
| Вага товару | 6.98 фунта |
| матеріал | пластик |
10. Гарантія та підтримка
For warranty information and technical support, please refer to the documentation provided with your purchase or contact the authorized OWON distributor or seller. Specific warranty terms may vary by region and retailer. Keep your proof of purchase for warranty claims.