GS1-L Industrial Smart LoRa Multi-Sensor
“
Technical Specifications
- Product Name: GS1-L Industrial Smart LoRa Multi-Sensor
- Power Input: DC5V-12V
- Connectivity: LoRa
- Sensors: Light sensor, Temperature & humidity sensor, PH
sensor*, CO sensor*, Wind speed sensor*, External temperature
sensor*, Soil temperature and humidity sensor*, External
temperature and humidity sensor*, Internal temperature and humidity
sensor - Interface: USB Type-C
Product Usage Instructions
1. Appearance Introduction
The device includes a light sensor, antenna, menu button, power
button, temperature & humidity sensor, sensor interface, and
DC5V-12V power port with a USB Type-C interface.
2. Screen Icons Introduction
The screen icons indicate various statuses such as storage
status, external power connection, error codes, device setup mode,
data transmission, LoRa connection status, battery level, and
sensor readings.
3. Device Operations
- Switch On: Press and hold the power button for
3 seconds until the screen lights up. Release the button to turn
the device on. - Switch Off: Press and hold the power button
for 3 seconds until the screen turns off to power off the
device. - Device Setup Mode: Press and hold the menu
button for 3 seconds while the device is on until the AP icon
flashes on the screen. - Manual Data Synchronization: Press the power
button once while the device is on to trigger a manual data sync.
The icon will flash during data transfer.
Frequently Asked Questions (FAQ)
Q: How do I reset the device to default settings?
A: To reset the device, switch it off, then
press and hold the menu button and power buttons together for at
least 8 seconds. Release the buttons when you hear the voice
guidance. Remember that all stored data will be lost if you reset
the device to default settings. Make sure to synchronize sensing
data to the UbiBot IoT platform or export it to your computer
before resetting.
“`
GS1-L
User Guide V 1.0 Industrial Smart LoRa Multi-Sensor
www.ubibot.com
This manual book is a general guidance for all types of our Industrial-grade GS1-L devices. PACKAGE LIST
Device
External antenna
Type-C USB cable
Note: Please ghten the antenna before use. Please note, only 4-wire cable as we provided can support data transmission. Some other cables may not
workwhen connecng the PC Tools.
INTRODUCTION
1.Appearance Introducon
Light sensor
Antenna
Menu buon Power buon
Temperature & humidity sensor Sensor interface
DC5V-12V power port USB Type-C
English
2.Screen Icons Introducon
Storage status
External power plugged in Error code Device setup mode Sending data LoRa connecon/ failure Baery level
PH sensor* CO sensor* Wind speed sensor*
Light sensor*
External temperature sensor* Soil temperature and humidity sensor* External temperature and humidity sensor* Internal temperature and humidity sensor
3. Device Operaons
Switch On Press and hold the power buon for 3 seconds unl the screen lights up. Release the buon and the device is now on.
The baery power will drain during the shipment and storage. You may fail to switch the device on for the first me. Please charge the device for 6-12 hours before you get started. This can also ensure a beer baery performance.
Switch Off Press and hold the power buon for 3 seconds unl the screen is off. The device is now off.
Device Setup Mode With the device switched on, press and hold the menu buon for 3 seconds. Release the buon unl the AP icon flashes on the screen.
Manual Data Synchronisaon With the device switched on, press the power buon once to trigger a manual data sync. The icon will flash while the data is being transferred. You can also hear the voice guidance. Toggle Screen Readings Press the menu buon once to toggle between the internal sensor readings and external probe readings and sensing data simultaneously.
Switch On/Off Voice Guide Double press the menu buon to enable or disable the voice guide. This will also refresh the last sensing data.
Toggle Celsius or Fahrenheit Double press the power buon to toggle between displaying Celsius or Fahrenheit. This will also refresh the last sensing data.
Display Backlight Pressing either of the buons will switch on the display backlight for a short me. Pressing both of the two buons at the same me will keep the backlight alight constantly. Pressing another me will switch off the backlight.
Reset to Default Sengs Switch the device off, then press and hold the menu buon and power buons together for at least 8 seconds. Release the buons when you hear the voice guidance “The device will now reset”.
ALL STORED DATA WILL BE LOST IF YOU RESET YOUR DEVICE TO DEFAULT SETTINGS! REMEMBER TO SYNCHRONISE THE SENSING DATA TO THE UbiBot IoT PLATFORM OR EXPORT THE DATA TO YOUR COMPUTER BEFORE RESETTING IT.
DEVICE SETUP OPTIONS
Download the App from www.ubibot.com/setup , or search for “UbiBot Connect” on the App Store or Google Play.
Launch the App and log in. In the gateway page, tap the “+” to start adding your device. Then please follow the in-app instrucons to complete the setup.
English
TECHNICAL SPECIFICATIONS
903-927 M Hz Built-in 2500mAh lithium baery (Rated Capacity) Opmal working condions: -20°C to 60°C, 10% to 90%RH Flame resistant ABS + PC Type-C, DC5V/2A or 12V/1A power supply Built-in Memory: 50,000 sensing data 115mm x 90mm x 55mm
FCC STATEMENT
This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protecon against harmful interference in a residenal installaon. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instrucons, may cause harmful interference to radio communicaons. However, there is no guarantee that interference will not occur in a parcula installaon. If this equipment does cause harmful interference to radio or television recepon, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
Reorient or relocate the receiving antenna. Increase the separaon between the equipment and receiver. Connect the equipment into an outlet on a circuit diferent from that to which the receiver is connected. Consult the dealer or an experienced radio/TV technician for help. Cauon: Any changes or modificaons to this device not explicitly approvedby manufacturer could void your authority to operate this equipment.
This device complies with part 15 of the FCC Rules. Operaon is subject to the following two condions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operaon.
This equipment complies w it h FCC radiat ion exposure limit s set fort h for an uncont rolled environment . This equipment should be inst alled and operat ed w it h minimum dist ance 0cm bet w een t he radiat or and your body.
Documents / Resources
![]() |
UBIBOT GS1-L Industrial Smart LoRa Multi-Sensor [pdf] User Guide GS1-L, GS1-L Industrial Smart LoRa Multi-Sensor, Industrial Smart LoRa Multi-Sensor, Smart LoRa Multi-Sensor, LoRa Multi-Sensor, Multi-Sensor |