true ERC112D Temperature Control Kit Instruction Manual

true-logo

true ERC112D Temperature Control Kit

true-ERC112D-Temperature-Control-Kit-product-image

Danfoss ERC112D Programming Instruction

STOP! All work detailed in these instructions must be done by a qualified technician.

Specifications

  • Subject: Danfoss ERC112D Universal Programming Instructions
  • Date: February 28, 2024
  • Models / Parts Affected: Temperature Control Kit P#848288
  • Voltages: All Voltages

Overview

  • Universal Danfoss ERC112D Temperature control kit contains all components potentially required for repairing a temperature control failure. Use of components will vary by repair.
  • The replacement control is preprogrammed for universal use and may require changes to parameter settings based on model type and application.
  • Some component operations may change with new universal settings.

CVM/GDM/TCR/TD/TMC/TUC/TWT REFRIGERATORS ONLY: No programming changes required.

Other Instructions
Follow the links/QR codes for digital copies of instructions associated with this kit.true-ERC112D-Temperature-Control-Kit-image (1)

Before You Begin

If adjusting the set point to 41°F (5°C) or greater, place the provided hazardous food warning label below the serial label inside the appliance as shown in fig. 1. This label notifies users the appliance has been set to maintain a temperature above outside NSF perishable food storage guidelines. true-ERC112D-Temperature-Control-Kit-image (2)

Installation

TOAM-72 ONLY: Verify the third defrost probe’s operation. If operating correctly reuse the probe. If operating incorrectly, please see “TOAM-72 Only — Third Defrost Probe” section (pg. 4).

  • CAUTION! Electrical shock or burn hazard. Powering off an electronic control does not remove power from all components. Unplug the unit or turn off the power supply before installation.
  • CAUTION! Sharp edges. Take care when installing, cleaning, servicing, and/or maintaining the equipment.true-ERC112D-Temperature-Control-Kit-image (3)

Control Program Structure

  • Parameters are arranged in parameter groups according to their purpose (see fig. 2a). For example, all fan operations are found within the FAn parameter group (see fig. 2b).
  • For more information on navigating the control programming, please see “Adjust Parameters” section.true-ERC112D-Temperature-Control-Kit-image (4)

Unlock Control

  1. Press any button to show the current lock status.true-ERC112D-Temperature-Control-Kit-image (5)
  2. If the display shows unL, proceed to “Enter Password” section. If the display shows Loc, press and hold the back button true-ERC112D-Temperature-Control-Kit-image (6)and the up arrow true-ERC112D-Temperature-Control-Kit-image (7)until the display shows unL.
    NOTE: The control will lock after 60 seconds of inactivity.
    true-ERC112D-Temperature-Control-Kit-image (7)
  3. Proceed to “Change System of Measure,” “Enter Password,” or “Adjust the Set Point” sections.

Change System of Measure
The display can show the temperature in either Fahrenheit or Celsius.

  1. Unlock the display. See “Unlock Control” section.
  2. Press the back buttontrue-ERC112D-Temperature-Control-Kit-image (6)true-ERC112D-Temperature-Control-Kit-image (7)

Enter Password

NOTE: After three (3) consecutive incorrect password entries, the control will lock for 15 minutes.

  1. Push and hold both the uptrue-ERC112D-Temperature-Control-Kit-image (10) arrows until the  display shows PAS.true-ERC112D-Temperature-Control-Kit-image (11)
  2. Wait for the display to show 000. true-ERC112D-Temperature-Control-Kit-image (12)
  3. Press the down arrow until the display shows 989.true-ERC112D-Temperature-Control-Kit-image (13)
  4. Press okaytrue-ERC112D-Temperature-Control-Kit-image (14) to show PS2.true-ERC112D-Temperature-Control-Kit-image (15)
  5. Wait for the display to show tHE.true-ERC112D-Temperature-Control-Kit-image (16)
  6. Proceed to “Adjust Parameters” or “Adjust the Set Point” sections.

Danfoss ERC112D Programming Instruction

true-ERC112D-Temperature-Control-Kit-image (17)

Adjust Parameters

  • See table 1 (next page) for required parameter adjustments before proceeding.
  • The figures show how to, in the parameter group FAn, change the parameter FCt to the parameter setting FAo (also shown in fig. 3). This setting change may not be required for your application.
    NOTE: Incorrect parameter settings can lead to improper appliance operation and unsafe product temperatures.
  1. Unlock the control. See “Unlock Control” section.
    NOTE: The control will lock after 60 seconds of inactivity.
  2. Enter the password and enter the programming. See “Enter Password” section.true-ERC112D-Temperature-Control-Kit-image (18)
  3. Press the up true-ERC112D-Temperature-Control-Kit-image (10) arrow as needed to show the desired parameter group.true-ERC112D-Temperature-Control-Kit-image (19)
  4. Press okaytrue-ERC112D-Temperature-Control-Kit-image (14) to select the parameter group.true-ERC112D-Temperature-Control-Kit-image (20)
  5. Press the up or down arrow as needed to show the desired parameter.true-ERC112D-Temperature-Control-Kit-image (21)
  6. Press okay to select the parameter.true-ERC112D-Temperature-Control-Kit-image (22) true-ERC112D-Temperature-Control-Kit-image (22)
  7. Press the up or down arrow as needed to show the desired parameter setting.true-ERC112D-Temperature-Control-Kit-image (24)
  8. Press okay to select the parameter setting. The display will return to the selected parameter.true-ERC112D-Temperature-Control-Kit-image (25)
  9. Press the back buttontrue-ERC112D-Temperature-Control-Kit-image (6) to return to the selected parameter group. Repeat steps 3-8 as needed to adjust parameter settings per table 1 (next page).true-ERC112D-Temperature-Control-Kit-image (26)
  10. Exit the programming.
    • Press the back button twice (x2) OR
    • Leave the control inactive for 30 seconds

Parameter Setting Adjustments

  • Table 1 shows how to alter the universal control program to fit your specific model and application.
  • Locate your model type, and then change the parameter settings to the values shown. For instructions on changing parameter settings, see “Adjust Parameters” section.
  • FREEZER MODELS ONLY: Be sure to change duA before adjusting any other parameter setting.

After changing the programming, be sure to adjust the set point for the application per table 2.

TOAM-72 ONLY — Third Defrost Probe

  • Verify the third defrost probe’s operation. If operating correctly reuse the probe.
  • If operating incorrectly, remove a tooth (see fig. 4) from a provided defrost probe.
  • For an additional defrost probe, in the USA or Canada, please contact our parts department at 800-424-8783 or PartsInquiries@TrueMfg.com. For all other locations, please see the contact information.true-ERC112D-Temperature-Control-Kit-image (27)
Model Type Table 1. Required Parameter Setting Changes by Model
Parameter Group tHE FAn dEF CoP ASi
Parameter SPr diF duA* FCt dii dAi dit dAt Ftd doC dEt dE2 dt2 dSo CSt S3A S4A diC o2C o4C
CPT – – – – – – – – – – – – – – – EuA – – – –
CVM – – – – – – – – – – – – – – – – – – – –
FLM (Freezer)

(1 Cond Unit)

– – du2 – – – – – 0°F (-17.8°C) – – – – – – – – – – –
GDIM – – du2 – – – – – 12°F (-11.1°C) – -10°F (-23.3°C) – – – – – – dCo – –
GDM (Refrigerator) – – – – – – – – – – – – – – – – – – –
GDM (Wine) – – – FAo – – – – – – – – – – – – – – – –
GDM (Freezer)

(1 Cond Unit)

– – du2 – – – – – 0°F (-17.8°C) – – – – – – – – dCo – –
GDM-LTF

(1 Cond Unit)

– – du2 – – – – – 0°F (-17.8°C) – – -40°F (-40°C) – – – – – dCo – –
Glass Chillers – – du2 – – – – – 0°F (-17.8°C) – – – – – – – – – – –
T-Series (Refrigerator) – – – – – – – – – – – – – – – – – dCo – –
T-Series (Freezer) (1 Cond Unit) – – du2 – – – – – 0°F (-17.8°C) – – – – – – – – dCo – –
TBR – – – – – – – – – – – – – – – – – – – –
TBR (Wine) – – – FAo – – – – – – – – – – – – – – – –
TCF – – du2 – – – – – 0°F (-17.8°C) – – – 50°F (10°C) – – – – – – –
TCGG – – – – – – 75 90 – 180 -13°F (-25°C) – – – – – – – – –
TCR – – – – – – – – – – – – – – – – – – – –
TD – – – – – – – – – – – – – – – – – – – –
TDM – – – FAo – 6 – – – – – – – – – – – – – –
TDM-CW – – – FAo – 6 – – – – – – – – – – – – – –
TFP – 3°F (1.7°C) – FAo – 3 2 – – – 5°F (-15°C) – – – 2 – – – – –
TGN (Refrigerator) – – – – – – – – – – – – – – – – – dCo – –
TGN (Freezer) – – du2 – – – – – 0°F (-17.8°C) – – – – – – – – dCo – –
THAC – – – FA0 – 1 – – – – – – – oFF – – – – – –
Model Type Table 1. Required Parameter Setting Changes by Model
Parameter Group tHE FAn dEF CoP ASi
Parameter SPr diF duA* FCt dii dAi dit dAt Ftd doC dEt dE2 dt2 dSo CSt S3A S4A diC o2C o4C
TMC – – – – – – – – – – – – – – – – – – – –
TOAM-30/36 – – – FAo – 1 – – – – – – – oFF – – – – – –
TOAM-48 – – – FAo – 1 – – – – – – – oFF – EuA – – – SCC
TOAM-72 – – – FAo – 1 – – – – – – – oFF – EuA EuA – tCC SCC
TPP – 3°F (1.7°C) – FAo – 3 2 – – – 5°F (-15°C) – – – 2 – – – – –
TRCB – – – FAo – – – – – – – – – – – – – – – –
TSSU – 3°F (1.7°C) – FAo – 3 2 – – – 5°F (-15°C) – – – 2 – – – – –
TUC/TWT (Refrigerator) – – – – – – – – – – – – – – – – – – – –
TUC/TWT (Wine) – – – FAo – – – – – – – – – – – – – – – –
TUC/TWT (Freezer) – – du2 – – – – – 0°F (-17.8°C) – – – – – – – – – – –
TUFADA 1 – du2 – 180 8 – – 0°F (-17.8°C) 240 – -25°F (-31.7°C) – – 6 – – – – –
TURADA 1 – – – 180 8 – – – 240 9°F (-12.8°C) – – – 6 – – – – –
TUWADA 1 – – FAo 180 8 – – – 240 9°F (-12.8°C) – – – 6 – – – – –

Adjust the Set Point (After Programming)

  • Changing the set point adjusts the appliance operation to
  • keep optimal product temperature. See table 2 for factory-recommended temperature set point adjustments based on model.

NOTE: Adjust the temperature set point after making programming adjustments.

true-ERC112D-Temperature-Control-Kit-image (28)

NOTE: The best set point for your application may vary from the factory-recommended setting.

  1. Unlock the control. See “Unlock Control.”
    NOTE: The control will lock after 60 seconds of inactivity.
  2. Press the uptrue-ERC112D-Temperature-Control-Kit-image (10) arrow to show the current setting.true-ERC112D-Temperature-Control-Kit-image (29)
  3. Press the up or down arrow until the display shows the desired set point.true-ERC112D-Temperature-Control-Kit-image (30)
  4. Leave the display inactive until it shows the current appliance temperature.

true-ERC112D-Temperature-Control-Kit-image (31)

Table 2. Factory-Recommended Temperature Set Points
Model Set Point
CPT No further changes required
CVM No further changes required
FLM (Freezer)

(1 Cond Unit)

No further changes required
GDIM 18°F (-7.8°C)
GDM (Refrigerator) No further changes required
GDM (Red Wine) 55°F (12.8°C)
GDM (White Wine) 45°F (7.2°C)
GDM (Freezer)

(1 Cond Unit)

No further changes required
GDM-LTF

(1 Cond Unit)

-15°F (-26.1°C)
Glass Chillers 4°F (-15.5°C)
T-Series (Refrigerator) No further changes required
T-Series (Freezer) (1 Cond Unit) No further changes required
TBR 34°F (1.1°C)
TBR (Red Wine) 55°F (12.8°C)
TBR (White Wine) 45°F (7.2°C)
TCF No further changes required
TCGG No further changes required
TCR No further changes required
TD No further changes required
TDM 38°F (3.3°C)
TDM-CW 55°F (12.8°C)
TFP 34°F (1.1°C)
TGN No further changes required
THAC 38°F (3.3°C)
TMC No further changes required
TOAM 38°F (3.3°C)
TPP 34°F (1.1°C)
TRCB No further changes required
TSSU 34°F (1.1°C)
TUC/TWT (Refrigerator) No further changes required
Table 2. Factory-Recommended Temperature Set Points
Model Set Point
TUC/TWT (Red Wine) 55°F (12.8°C)
TUC/TWT (White Wine) 45°F (7.2°C)
TUC/TWT (Freezer) No further changes required
TUFADA No further changes required
TURADA No further changes required
TUWADA 55°F (12.8°C)

Questions or Concerns
For more information, please contact our Technical Service team. See contact information below.

Contact Us

BUILDING THE FINEST COMMERCIAL REFRIGERATION — True, “The Best of the Cold Ones”

FAQ

What should I do if the control locks after inactivity?

If the control locks after 60 seconds of inactivity, press any button to check the lock status. If it shows 'Loc,' press and hold the back button and up arrow until 'unL' appears.

How can I unlock the control?

To unlock the control, follow the steps mentioned in the 'Enter Password' section of the manual.

Documents / Resources

PDF thumbnailERC112D Temperature Control Kit
Instruction Manual · ERC112D Temperature Control Kit, ERC112D, Temperature Control Kit, Control Kit, Kit

References

Ask a Question

Use this section to ask about setup, compatibility, troubleshooting, or anything missing from this manual.

Ask a Question

Ask about setup, compatibility, troubleshooting, or anything missing from this manual. Name and email are optional.