true ERC112D Temperature Control Kit Instruction Manual

ERC112D Temperature Control Kit

Specifications:

  • Manufacturer: True Manufacturing Co., Inc.
  • Model: Danfoss ERC112D
  • Part Number: 836831
  • Voltages: All Voltages

Product Information:

The Danfoss ERC112D Universal Temperature control kit is
designed to address temperature control failures in refrigerators.
It is preprogrammed for universal use but may require adjustments
based on the specific model and application.

Installation:

Before beginning the installation process, ensure to verify the
operation of the third defrost probe for TOAM-72 models. Follow the
provided instructions carefully to avoid electrical shock or injury
due to sharp edges.

Parameter Control Program Structure:

The control parameters are organized into groups based on their
functions. For example, fan operations are located within the FAn
parameter group. Refer to the provided figures for guidance on
navigating the program structure.

Product Usage Instructions:

Entering Password:

  1. Press any button to display the current lock status.
  2. If the display shows ‘unL,’ proceed to the Enter Password
    section. If it shows ‘Loc,’ press and hold the back button and up
    arrow until ‘unL’ appears.

Changing System of Measure:

  1. Push and hold both the up and down arrows until the display
    shows ‘PAS.’
  2. Wait for the display to show ‘000.’

Adjusting Set Point:

  1. Proceed to the ‘Set Point’ section in the control programming
    structure.
  2. Make necessary adjustments using the provided
    instructions.

FAQ:

Q: What should I do if the control locks after inactivity?

A: If the control locks after 60 seconds of inactivity, press
any button to check the lock status. If it shows ‘Loc,’ press and
hold the back button and up arrow until ‘unL’ appears.

Q: How can I unlock the control?

A: To unlock the control, follow the steps mentioned in the
‘Enter Password’ section of the manual.

TRUE MANUFACTURING CO., INC.
Technical Service Instruction
Danfoss ERC112D Programming Instruction

836831

STOP! All work detailed in these instructions must be done by a qualified technician.
Subject: Danfoss ERC112D Universal Programming Instructions Date: February 28, 2024 Models / Parts Affected: Temperature Control Kit P#848288 Voltages: All Voltages
Overview
Universal Danfoss ERC112D Temperature control kit contains all components potentially required for repairing a temperature control failure. Use of components will vary by repair.
The replacement control is preprogrammed for universal use and may require changes to parameter settings based on model type and application. Some component operations may change with new universal settings.
CVM/GDM/TCR/TD/TMC/TUC/TWT REFRIGERATORS ONLY: No programming changes required.

Other Instructions
Follow the links/QR codes for digital copies of instructions associated
with this kit.

112D Cover Page P#848289

113D Cover Page P#848246

Wiring P#848245

Before You Begin
If adjusting the set point to 41°F (5°C) or greater, place the provided hazardous food warning label below the serial label inside the appliance as shown in fig. 1. This label notifies users the appliance has been set to maintain a temperature above outside NSF perishable food storage guidelines.

Mounting P#848284

112D Programming (this document)

113D Programming P#836832

Fig. 1. Hazardous food warning label intended location.

Installation
TOAM-72 ONLY: Verify the third defrost probe’s operation. If operating correctly reuse the probe. If operating incorrectly, please see “TOAM-72 Only — Third Defrost Probe” section (pg. 4).
CAUTION! Electrical shock or burn hazard. Powering off an electronic control does not remove power from all components. Unplug the unit or turn off the power supply before installation.
CAUTION! Sharp edges. Take care when installing, cleaning, servicing, and/or maintaining the equipment.

ECO

°C

°F

Parameter Group Parameter

Control Program Structure
Parameters are arranged in parameter groups according to their purpose (see fig. 2a). For example, all fan operations are found within the FAn parameter group (see fig. 2b).
For more information on navigating the control programming, please see “Adjust Parameters” section.

Parameter Setting Fig. 2a. Control program organization.

ECO

°C

°F

tHE FAn

Lig

Pud

dEF

CoP

FCt

Con

Fdt

diS

FC2

ALA

AHC

Aut

ECS

SEt

ECA

FAo

ASi

SEr

Fig. 2b. Navigating the program structure to reach

parameter setting FAo.

BUILDING THE FINEST COMMERCIAL REFRIGERATION — True, “The Best of the Cold Ones”

TEC_WI_1299 | REV. F | EN

02/28/2024 EA | E561

Page 1 of 7

TRUE MANUFACTURING CO., INC.
Technical Service Instruction
Danfoss ERC112D Programming Instruction

836831

Defrost / Back /

ECO

Show °F or °C

Power / Okay

Compressor Running

°C °F

Set Point / Up Arrow

Evaporator Fan Running

Appliance in Defrost

Set Point / Down Arrow

Alarm

Unlock Contol
1. Press any button to show the current lock status.

ECO

°C

°F

2. If the display shows unL, proceed to “Enter Password” section. If the display shows Loc, press and hold the back button and the up arrow until the display shows unL.
NOTE: The control will lock after 60 seconds of inactivity.

ECO

°C

°F

Enter Password
NOTE: After three (3) consecutive incorrect password entries, the control will lock for 15 minutes.

1. Push and hold both the up display shows PAS.

and down

arrows until the

ECO

°C

°F

2. Wait for the display to show 000.

ECO

°C

°F

3. Proceed to “Change System of Measure,” “Enter Password,” or “Adjust the Set Point” sections.
Change System of Measure
The display can show the temperature in either Fahrenheit or Celsius. 1. Unlock the display. See “Unlock Control” section. 2. Press the back button .

ECO

°C

°F

ECO

°C

°F

3. Press the down arrow until the display shows 989.

ECO

°C

°F

4. Press okay to show PS2.

ECO

°C

°F

5. Wait for the display to show tHE.

ECO

°C

°F

6. Proceed to “Adjust Parameters” or “Adjust the Set Point” sections.

BUILDING THE FINEST COMMERCIAL REFRIGERATION — True, “The Best of the Cold Ones”

TEC_WI_1299 | REV. F | EN

02/28/2024 EA | E561

Page 2 of 7

TRUE MANUFACTURING CO., INC.
Technical Service Instruction
Danfoss ERC112D Programming Instruction

836831

Defrost / Back /

ECO

°C

Show °F or °C

°F

Power / Okay
Adjust Parameters
See table 1 (next page) for required parameter adjustments before proceedintg.
The figures show how to, in the parameter group FAn, change the parameter FCt to the parameter setting FAo (also shown in fig. 3). This setting change may not be required for your application.
NOTE: Incorrect parameter settings can lead to improper appliance operation and unsafe product temperatures.
1. Unlock the control. See “Unlock Control” section. NOTE: The control will lock after 60 seconds of inactivity.
2. Enter the password and enter the programming. See “Enter Password” section.

ECO

°C

°F

Set Point / Up Arrow
Set Point / Down Arrow

Compressor Running Evaporator Fan Running Appliance in Defrost Alarm

Parameter Group

tHE

FAn

Lig

Pud

Parameter

dEF

CoP

FCt

Con

Fdt

diS

FC2

ALA

Parameter Setting

AHC

Aut

ECS

SEt

ECA

FAo

ASi

SEr

Fig. 3. Navigating the control program parameters and settings.

3. Press the up or down desired parameter group.

arrow as needed to show the

ECO

°C

°F

7. Press the up or down arrow as needed to show the desired parameter setting.

ECO

°C

°F

4. Press okay to select the parameter group.

ECO

°C

°F

8. Press okay to select the parameter setting. The display will return to the selected parameter.

ECO

°C

°F

5. Press the up or down arrow as needed to show the desired parameter.

ECO

°C

°F

6. Press okay to select the parameter.

ECO

°C

°F

9. Press the back button to return to the selected parameter group. Repeat steps 3-8 as needed to adjust parameter settings per table 1 (next page).

ECO

°C

°F

10. Exit the programming. · Press the back button twice (x2) OR · Leave the control inactive for 30 seconds

BUILDING THE FINEST COMMERCIAL REFRIGERATION — True, “The Best of the Cold Ones”

TEC_WI_1299 | REV. F | EN

02/28/2024 EA | E561

Page 3 of 7

Page 4 of 7

836831

Parameter Setting Adjustments
Table 1 shows how to alter the universal control program to fit your specific model and application.
Locate your model type, and then change the parameter settings to the values shown. For instructions on changing parameter settings, see “Adjust Parameters” section.
*FREEZER MODELS ONLY: Be sure to change duA before adjusting any other parameter setting.
After changing the programming, be sure to adjust the set point for the application per table 2.

TOAM-72 ONLY — Third Defrost Probe
Verify the third defrost probe’s operation. If operating correctly reuse the probe.
If operating incorrectly, remove a tooth (see fig. 4) from a provided defrost probe.
For an additional defrost probe, in the USA or Canada, please contact our parts department at 800-424-8783 or PartsInquiries@TrueMfg.com. For all other locations, please see the contact information.

Fig. 4. Remove the center tooth.

02/28/2024 EA | E561

BUILDING THE FINEST COMMERCIAL REFRIGERATION — True, “The Best of the Cold Ones”

TRUE MANUFACTURING CO., INC.
Technical Service Instruction
Danfoss ERC112D Programming Instruction

Model Type

Parameter Group

Parameter SPr

CPT

CVM

FLM (Freezer) (1 Cond Unit)

GDIM

GDM (Refrigerator)

GDM (Wine)

GDM (Freezer) (1 Cond Unit)

GDM-LTF (1 Cond Unit)

Glass Chillers

T-Series (Refrigerator)

T-Series (Freezer) (1 Cond Unit)

Table 1. Required Parameter Setting Changes by Model

tHE

FAn

dEF

CoP

ASi

diF duA* FCt dii dAi dit dAt

Ftd

doC

dEt

dE2

dt2

dSo CSt S3A S4A diC o2C o4C

– —-

– – EuA – – – –

– —-

—— –

du2 – – – – – 0°F (-17.8°C) –

—— –

du2 – – – – – 12°F (-11.1°C) – -10°F (-23.3°C)

– —-

– FAo – – – –

– – – – dCo – –

—— –

—— –

du2 – – – – – 0°F (-17.8°C) –

– – – – dCo – –

du2 – – – – – 0°F (-17.8°C) –

-40°F (-40°C)

– – – – dCo – –

du2 – – – – – 0°F (-17.8°C) –

– —-

—— –

– – – – dCo – –

du2 – – – – – 0°F (-17.8°C) –

– – – – dCo – –

TBR

– —-

—— –

TBR (Wine)

– FAo – – – –

—— –

TCF

du2 – – – – – 0°F (-17.8°C) –

50°F (10°C) – – – – – – –

TCGG

– – – 75 90

180 -13°F (-25°C)

—— –

TCR

– —-

—— –

TD

– —-

—— –

TDM

– FAo – 6 – –

—— –

TDM-CW

– FAo – 6 – –

—— –

TFP

– 3°F (1.7°C) – FAo – 3 2 –

– 5°F (-15°C)

-2- – – – –

TGN (Refrigerator)

– —-

– – – – dCo – –

TGN (Freezer)

du2 – – – – – 0°F (-17.8°C) –

– – – – dCo – –

THAC

– FA0 – 1 – –

oFF – – – – – –

TEC_WI_1299 | REV. F | EN

Page 5 of 7

836831

Model Type

Parameter Group Parameter SPr

TMC

Table 1. Required Parameter Setting Changes by Model

tHE

FAn

dEF

CoP

ASi

diF duA* FCt dii dAi dit dAt

Ftd

doC

dEt

dE2

dt2

dSo CSt S3A S4A diC o2C o4C

– —-

—— –

TOAM-30/36

– FAo – 1 – –

oFF – – – – – –

TOAM-48

– FAo – 1 – –

oFF – EuA – – – SCC

TOAM-72

– FAo – 1 – –

oFF – EuA EuA – tCC SCC

TPP

– 3°F (1.7°C) – FAo – 3 2 –

– 5°F (-15°C)

-2- – – – –

TRCB

– FAo – – – –

—— –

TSSU

– 3°F (1.7°C) – FAo – 3 2 –

– 5°F (-15°C)

-2- – – – –

TUC/TWT (Refrigerator) –

– —-

—— –

TUC/TWT (Wine)

– FAo – – – –

—— –

TUC/TWT (Freezer)

du2 – – – – – 0°F (-17.8°C) –

—— –

TUFADA

1

du2 – 180 8 – – 0°F (-17.8°C) 240

-25°F (-31.7°C)

-6- – – – –

TURADA

1

– 180 8 – –

240 9°F (-12.8°C)

-6- – – – –

TUWADA

1

– FAo 180 8 – –

240 9°F (-12.8°C)

-6- – – – –

02/28/2024 EA | E561

BUILDING THE FINEST COMMERCIAL REFRIGERATION — True, “The Best of the Cold Ones”

TRUE MANUFACTURING CO., INC.
Technical Service Instruction
Danfoss ERC112D Programming Instruction

Continue to next page

TEC_WI_1299 | REV. F | EN

TRUE MANUFACTURING CO., INC.
Technical Service Instruction
Danfoss ERC112D Programming Instruction

Defrost / Back /

ECO

Show °F or °C

Power / Okay

°C

Set Point /

°F

Up Arrow

Set Point / Down Arrow

836831
Compressor Running Evaporator Fan Running Appliance in Defrost Alarm

Adjust the Set Point (After Programming)
Changing the set point adjusts the appliance operation to keep optimal product temperature. See table 2 for factoryrecommended temperature set point adjustments based on model.

NOTE: Adjust the temperature set point after making programming adjustments.
NOTE: The best set point for your application may vary from the factory-recommended setting.

1. Unlock the control. See “Unlock Control.” NOTE: The control will lock after 60 seconds of inactivity.

2. Press the up setting.

or down

arrow to show the current

ECO

°C

°F

3. Press the up or down arrow until the display shows the desired set point.

ECO

°C

°F

4. Leave the display inactive until it shows the current appliance temperature.

ECO

°C

°F

Table 2. Factory-Recommended Temperature Set Points

Model

Set Point

CPT

No further changes required

CVM FLM (Freezer) (1 Cond Unit)
GDIM

No further changes required No further changes required
18°F (-7.8°C)

GDM (Refrigerator)

No further changes required

GDM (Red Wine)

55°F (12.8°C)

GDM (White Wine)
GDM (Freezer) (1 Cond Unit) GDM-LTF (1 Cond Unit) Glass Chillers
T-Series (Refrigerator)
T-Series (Freezer) (1 Cond Unit)
TBR

45°F (7.2°C) No further changes required
-15°F (-26.1°C) 4°F (-15.5°C) No further changes required No further changes required 34°F (1.1°C)

TBR (Red Wine)

55°F (12.8°C)

TBR (White Wine)

45°F (7.2°C)

TCF

No further changes required

TCGG

No further changes required

TCR

No further changes required

TD

No further changes required

TDM

38°F (3.3°C)

TDM-CW

55°F (12.8°C)

TFP

34°F (1.1°C)

TGN

No further changes required

THAC

38°F (3.3°C)

TMC

No further changes required

TOAM

38°F (3.3°C)

TPP

34°F (1.1°C)

TRCB

No further changes required

TSSU

34°F (1.1°C)

TUC/TWT (Refrigerator)

No further changes required

BUILDING THE FINEST COMMERCIAL REFRIGERATION — True, “The Best of the Cold Ones”

TEC_WI_1299 | REV. F | EN

02/28/2024 EA | E561

Page 6 of 7

TRUE MANUFACTURING CO., INC.
Technical Service Instruction
Danfoss ERC112D Programming Instruction

Table 2. Factory-Recommended

Temperature Set Points

Model

Set Point

TUC/TWT (Red Wine)

55°F (12.8°C)

TUC/TWT (White Wine)

45°F (7.2°C)

TUC/TWT (Freezer)

No further changes required

TUFADA

No further changes required

TURADA

No further changes required

TUWADA

55°F (12.8°C)

836831

Questions or Concerns
For more information, please contact our Technical Service team. See contact information below.

Contact Us
North America ­ USA, Canada & Caribbean
Warranty Phone: +1 855 878 9277 Warranty Fax: +1 636 980 8510 Warranty Email: WarrantyInquiries@TrueMfg.com Technical Phone: +1 855 372 1368 Technical Email: Service@TrueMfg.com 7:00am-6:00pm CST Monday-Friday; 8:00am-12:00pm Saturday

Mexico
Phone: +52 555 804 6343/44 Service-MexicoCity@TrueMfg.com 9:00am-5:30pm M-F
Latin America
Phone: +52 555 804 6343/44 ServiceLatAm@TrueMfg.com 9:00am-5:30pm M-F

UK, Ireland, Middle East, Africa & India
Phone: +44 (0) 800 783 2049 Service-EMEA@TrueMfg.com 8:30am-5:00pm M-F
Australia
Phone: +61 2 9618 9999 Service-Aus@TrueMfg.com 8:30am-5:00pm M-F

BUILDING THE FINEST COMMERCIAL REFRIGERATION — True, “The Best of the Cold Ones”

TEC_WI_1299 | REV. F | EN

02/28/2024 EA | E561

European Union & Commonwealth of Independent States
Phone: +41 61 563 0705 Service-EMEA@TrueMfg.com 8:00am-5:00pm M-F
Page 7 of 7

Documents / Resources

true ERC112D Temperature Control Kit [pdf] Instruction Manual
ERC112D Temperature Control Kit, ERC112D, Temperature Control Kit, Control Kit, Kit

References

Leave a comment

Your email address will not be published. Required fields are marked *