CD10094 TR2MOVE Air Diffusers
“
Specifications
- Product: Air diffusers – Ventilation grille TR2MOVE
- Model: TR2MOVE
- Front border: 1
- Countersunk holes: 2
- Attachment (AG): 3
Product Overview
The Air diffusers – Ventilation grille TR2MOVE is designed for
ventilation of internal spaces in industrial and comfort areas. It
is typically connected to a supply air or extract air system, which
is linked to an air handling unit.
Installation Manual
The installation manual provides guidance on correctly
installing the product to ensure safe and efficient use. It is
crucial for operating or service personnel to thoroughly read and
understand the manual before commencing any work.
Product Usage Instructions
Safety Precautions
It is essential to comply with safety notes and instructions
provided in the manual. The use of personal protective equipment
such as industrial safety helmets, protective gloves, and safety
shoes is recommended during installation, operation, and
maintenance.
Air Terminal Devices Usage
Air terminal devices supply cold or warm air to rooms within
specified temperature differences. Ensure proper installation in
various environments like humid rooms, potentially explosive
atmospheres, or areas with dust-laden air after assessing on-site
conditions.
Staff Qualification
Trained personnel should handle the installation, operation, and
maintenance tasks. They must possess adequate professional
training, technical knowledge, and experience to understand
potential hazards and risks associated with the work.
Personal Protective Equipment
Wear personal protective equipment throughout the work duration
to minimize health and safety risks. The appropriate protective
gear must be worn as per job requirements.
FAQ
Q: What should I do if the actual scope of delivery
differs?
A: In case of any discrepancies between the scope of delivery
and the manual, contact the manufacturer for clarification or
guidance on special versions or technical changes.
Q: Are there specific requirements for installation in
different environments?
A: Yes, installations in humid rooms, potentially explosive
areas, or places with dust-laden air require prior assessment based
on on-site conditions to ensure safe operation.
Q: Who should handle the installation and maintenance
tasks?
A: Trained personnel with professional knowledge and experience
should handle installation, operation, and maintenance activities
to ensure safety and efficiency.
“`
Product overview
Installation manual
GB/en
Air diffusers
Ventilation grille TR2MOVE
TROX Hesco Schweiz AG Neuhofstrasse 4 8630 Rüti ZH Switzerland Phone: +41 55 250 71 11 Fax: +41 55 250 73 10 E-Mail: troxhesco@troxgroup.com http://www.troxhesco.ch
CD10094, 09/2024, © 2021 TROX GmbH
Fig. 1: Schematic illustration TR2MOVE
1 Front border 2 Countersunk holes 3 Attachment (AG)
Important notes
Information on the installation manual
This manual enables operating or service personnel to correctly install the product described below and to use it safely and efficiently.
It is essential that these individuals read and fully understand this manual before starting any work. The basic prerequisite for safe working is to comply with the safety notes and all instructions in this manual.
The local regulations for health and safety at work and general safety regulations also apply.
Other applicable documentation
In addition to these instructions, the following documents must be observed:
Product data sheets
Limitation of liability
The information in this manual has been compiled with reference to the applicable standards and guidelines, the state of the art, and our expertise and experience of many years.
The manufacturer does not accept any liability for damages resulting from:
Non-compliance with this manual Incorrect use Operation or handling by untrained individuals Unauthorised modifications
Air diffusers Ventilation grille TR2MOVE
1
Safety
The actual scope of delivery may differ from the explanations and illustrations provided in this manual for special versions, the use of additional order options or as a result of recent technical changes.
Industrial safety helmet
Safety
Correct use
Air terminal devices are used for the ventilation of internal spaces in industrial and comfort areas. The air terminal devices are connected to a supply air or extract air system (by others), which is typically connected to an air handling unit.
Industrial safety helmets protect the head from falling objects, suspended loads, and the effects of striking the head against stationary objects.
Protective gloves
Air terminal devices supply cold or warm air to rooms (within the stated supply air to room air temperature differences).
Installation, operation and maintenance may have to meet increased hygiene requirements for certain areas of application.
Installation in humid rooms, areas with potentially explosive atmospheres or rooms with dust-laden or aggressive air has to be assessed beforehand because it depends on the actual conditions on site.
Protective gloves protect hands from friction, abrasions, punctures, deep cuts, and direct contact with hot surfaces.
Safety shoes
Staff
Qualification
Trained personnel Trained personnel are individuals who have sufficient professional or technical training, knowledge and actual experience to enable them to carry out their assigned duties, understand any potential hazards related to the work under consideration, and recognise and avoid any risks involved.
Personal protective equipment
Personal protective equipment must be worn for any work in order to reduce health or safety hazards to the minimum.
The appropriate protective equipment for a job must be worn for as long as the job takes.
Safety shoes protect the feet against crushing, falling parts, and slipping on slippery ground.
Repair and replacement parts
Only qualified personnel must repair the products, and they have to use genuine replacement parts.
Transport and storage
Delivery check
After delivery, carefully remove the packaging and check the device for any transport damage and completeness. In case of transport damage or incomplete delivery, inform the forwarding agent and the supplier immediately. After inspection of the goods, put the product back into its packaging to protect it from dust and contamination.
2
Air diffusers Ventilation grille TR2MOVE
Assembly
Fixing and installation material
Fixing and installation material is not part of the supply package (unless stated otherwise), but has to be provided by others; it has to be suitable for the installation situation.
Packaging Properly dispose of packaging material. Assembly General installation information Personnel: Trained personnel
Transport on site
CAUTION!
Danger of injury from sharp edges, sharp corners and thin sheet metal parts! Sharp edges, sharp corners and thin sheet metal parts may cause cuts or grazes.
Be careful when carrying out any work. Wear protective gloves, safety shoes and a
hard hat.
Observe the following points during transport:
Be careful when unloading or moving the product on site, and pay attention to the symbols and information on the packaging.
If possible, take the product in its transport packaging up to the installation location.
For fastening to the building structure, use only lifting and transport gear designed for the required load.
During transport, always secure the load against tipping and falling.
Bulky equipment should be transported by at least two people to prevent injury and damage.
Storage
Observe the following points for storage:
Store the product only in its original packaging Protect the product from the effects of weather Protect the product from humidity, dust and
contamination Storage temperature: -10 °C to 90 °C relative humidity: 80 % maximum, no conden-
sation
Protective equipment: Industrial safety helmet
Protective gloves
Safety shoes
Observe during installation:
Fix the product only to load-bearing structural elements.
Only load suspension with the device’s own weight. Adjacent components and connecting air ducts must be supported separately.
Use only approved and adequately sized fixing material (fixing material is not included in the supply package).
After installation, the air diffusers must be easily accessible for cleaning purposes.
Installation and sealing material provided by the manufacturer are usually enclosed in a bag in the package.
Protect the device from dust and con-
tamination
Before installation, ensure that the air-ducting components cannot be contaminated by construction activities (VDI, SWKI, Ö-norm). If this is not possible, at least cover the device or take other precautions to protect it from contamination. In this case, make sure the device is not in operation. Ensure that all components are clean before you install them. Clean thoroughly if necessary. When interrupting the installation procedure, protect all device openings from the ingress of dust or humidity.
Air diffusers Ventilation grille TR2MOVE
3
Assembly
Safety instructions for installation
CAUTION!
Risk of injury due to incorrect installation! Ventilation grilles can weigh up to 25 kg, depending on size and attachments. If they fall, there is a high risk of personal injury or damage to property. Depending on the installation situation, it must be ensured that suitable measures are taken to prevent falling.
In the case of ceiling installation or installation at great heights, additional safety measures may be required in addition to a suitable type of fastening (screw connection) to prevent the device from falling down.
Fixing types
Electrical voltage
DANGER!
Danger of electric shock! Do not touch any live components! Electrical equipment carries a dangerous electrical voltage.
Only skilled qualified electricians are allowed to work on the electrical system.
Switch off the power supply before working on any electrical equipment.
Fig. 2: Fixing types 1 Fastening -0: Fastening Standard countersunk hole.
Quantity countersunk holes
Height H
[mm]325
425
125
4
4
225
4
4
Length B [mm]
525
625
825
4
6
6
4
6
6
1025 6 6
1225 6 6
4
Air diffusers Ventilation grille TR2MOVE
Technical data Dimensions
Technical data
Fig. 3: Installation opening no entry
Fig. 4: Installation opening TR2MOVE-R/RA-BL
Air diffusers Ventilation grille TR2MOVE
5
Technical data
Fig. 5: Installation opening TR2MOVE-BS/BL
Fig. 6: Fixings 1 Fixing countersunk hole
6
Air diffusers Ventilation grille TR2MOVE
TR2MOVE TR2MOVE
Fixings Countersunk hole
NO
Type Countersunk hole
Technical data
Installation opening [mm] (B-10) x (H-15) (B-10) x (H-15)
Wall thickness X [mm] max. 15
Fig. 7: Screw hole pitch
Screw hole pitch TR2MOVE
Length B [mm] 225 325 425 525 625 825 1025 1225
X 250 350 450 550 650 850 1050 1250
Y 167 267 367 467 567 767 967 1167
Air diffusers Ventilation grille TR2MOVE
nxF –
2×283.5 2×383.5 2×483.5 2×583.5
7
Technical data
Screw hole pitch TR2MOVE
Height H [mm]
N
125
150
225
250
TR2MOVE max. weight grille [kg]
H/B
425
525
625
825
125
1.3
1.7
1.9
2.5
225
1.8
2.4
2.7
3.7
TR2MOVE max. weight of ball impact protection without grille [kg]
H/B
625
125
1.1
225
1.1
TR2MOVE weights attachment AG without grille [kg]
H/B
425
525
625
825
125
1.0
1.1
1.5
1.7
225
1.4
1.6
2.1
2.4
TR2MOVE weights attachment AS without grille [kg]
H/B
425
525
625
825
125
0.7
0.8
0.9
1.2
225
1.1
1.2
1.4
1.8
TR2MOVE weights attachment SAS without grille [kg]
H/B
425
525
625
825
125
0.8
0.9
1.1
1.4
225
1.3
1.4
1.7
2.2
Installation details
Air connection
Ventilation grilles do not have an air connection, they are installed directly into air ducts or similar.
C 125 225
1025 3.2 4.6
1225 3.8 5.5
825 1.2 1.2
1025 2.3 3.2
1225 2.6 3.6
1025 1.6 2.4
1225 1.7 2.6
1025 1.9 2.9
1225 2.0 3.2
8
Air diffusers Ventilation grille TR2MOVE
Dimensions
Technical data
Fig. 8: TR2MOVE-SELF
TR2MOVE-SELF Installation depth temperature indicator S [mm]
Construction TR2MOVE-SELF TR2MOVE-R/-RA-SELF
H [mm] 125 225 125 225
S [mm] 75 75 42 53
Air diffusers Ventilation grille TR2MOVE
9
Technical data
TR2MOVE-SELF Installation depths T [mm]
Attachment
without attachment AG AS
TR2MOVE-SELF
75 103 75
TR2MOVE-R/-RASELF
78
106
78
TR2MOVE-SELFBS/BL
124
152
124
TR2MOVE-SELF installation depths T [mm] with attachment SAS
Nominal width B [mm] 325 425 525 625 825 1025 1225
TR2MOVE-SELF
85 95 100 110 130 150 150
TR2MOVE-R/-RASELF 100 110 115 125 145 170 170
TR2MOVE-SELFBS/BL 155 175 195 195
TR2MOVE-R/-RASELF-BL 124 152 124
TR2MOVE-R/-RASELF-BL max. 170 max. 190 max. 190 max. 190
Fig. 9: TR2MOVE-VAR
10
Air diffusers Ventilation grille TR2MOVE
Technical data
TR2MOVE-VAR Installation depths T [mm]
Attachment without attachment
AG AS
H [mm] 125 225 125 225 125 225
TR2MOVE-VAR
200 93 200 103 200 93
TR2MOVE-R/-RAVAR 204 108 204 108 204 108
TR2MOVE-VARBS/BL 149 149 149
TR2MOVE-R/-RAVAR-BL 245 149 245 149 245 149
TR2MOVE-VAR installation depths T [mm] with attachment SAS
Nominal width B [mm] 325 425 525 625 825 1025 1225
H [mm] 125 225 125 225 125 225 125 225 125 225 125 225 125 225
TR2MOVE-VAR
200 100 200 110 200 115 200 125 200 145 200 170 200 170
TR2MOVE-R/-RAVAR 204 108 204 110 204 115 204 125 204 145 204 170 204 170
TR2MOVE-VARBS/BL 151 171 –
TR2MOVE-R/-RAVAR-BL 245 165 245 185 –
Fig. 10: TR2MOVE-BS/BL
Air diffusers Ventilation grille TR2MOVE
11
Initial commissioning
Fig. 11: TR2MOVE-R/RA-BL
TR2MOVE
Fixings Countersunk hole
NO
Installation opening [mm] (B-10) x (H-15) (B-10) x (H-15)
Initial commissioning
General information
Before you start commissioning, check the following points:
Check that the air diffusers are fitted correctly.
Remove protective foils, if any.
Ensure that all air diffusers are clean and free from residues and foreign matter.
Check electrical connections (if any) for correct Fig. 12: Attachments -AG
installation.
Damper element with opposed action blades,
Check proper fastening and connection with air adjustable
duct
For commissioning, see also VDI 6022, Sheet 1 Hygienic requirements for ventilation and air conditioning systems.
Volume flow rate balancing
Carefully turn the screw in (clockwise) and out (anti-clockwise) to adjust or fasten the hit and miss damper. Tighten the screw with max. 1.0 Nm
AG: manual adjustment AS/SAS with screwdriver
12
Air diffusers Ventilation grille TR2MOVE
Initial commissioning
Fig. 13: Attachments -AS Damper element with hit and miss damper, adjustable, secured with a locking screw Air pattern Setting the air direction on site using the TR2 key.
Fig. 14: Setting the air direction
Air diffusers Ventilation grille TR2MOVE
13
Maintenance and cleaning
Maintenance and cleaning
Please note:
The cleaning intervals given in the VDI 6022 standard apply.
Clean surfaces with a damp cloth. Use only common household cleaners, do not
use any aggressive cleaning agents. Do not use cleaning agents that contain
chlorine. Do not use equipment for removing stub-
born contamination, e.g. scrubbing sponges or scouring cream, as it may damage the surfaces.
Decommissioning
Once the device has reached the end of its service life, it must be dismantled and disposed of in an environmentally friendly manner.
Safety
Personnel
Disassembly may only be carried out by specially trained personnel.
Only trained and qualified electricians may work on the electrical system.
WARNING!
Risk of injury due to incorrect disassembly! Stored residual energy, sharp-edged components, sharp points and corners on and in the appliance or on the required tools can cause injuries. Therefore:
Make sure there is sufficient space before starting work.
Handle all open, sharp-edged components with care.
Disassemble components professionally. Be aware that some components are very heavy. Use lifting gear if necessary.
Secure components to prevent them from falling or toppling.
When in doubt, contact the manufacturer.
Disassembly
Before you start disassembly:
Switch off the device and secure it against being switched on accidentally.
Physically disconnect the entire power supply from the device and discharge any stored residual energy.
Remove operating and auxiliary materials as well as residual processing materials and dispose of them in an environmentally friendly manner.
Then professionally clean subassemblies and components and disassemble them in compliance with local occupational safety and environmental protection regulations.
Disposal
ENVIRONMENT!
Risk of harm to the environment due to incorrect disposal! Incorrect disposal may harm the environment.
Be sure to comply with the relevant national guidelines and regulations.
In case of doubt, contact your local authorities or a specialist disposal company.
Note: The grille must be dismantled for disposal. If no disposal or return agreement with TROX GmbH is in place, we recommend disposing of the materials as follows:
Pos. 1
2 3
Component
Front grille, attachment
self-acting blades electric actuator
Material/ waste code galvanised steel EWC
170404 Aluminium
Electronics
EWC European Waste Catalogue
Type of disposal
Scrap metal recycling
Electronic waste recy-
cling
14
Air diffusers Ventilation grille TR2MOVE
Documents / Resources
![]() |
TROX CD10094 TR2MOVE Air Diffusers [pdf] Owner's Manual CD10094, CD10094 TR2MOVE Air Diffusers, CD10094 TR2MOVE, Air Diffusers, Diffusers |