The DCC-1 allows users to use a DS type plug-in style module, and the DCC-1 to have two conditions/variables controlled from a single device DS module. Follow the steps below to install your DCC.

DCC-1 / Dual Condition Controller

In some circumstances, it is necessary to have a single device turned on (or off) when a second control condition is activated. There are many examples of this but the most common are:

  • Turn on an exhaust fan at night (or day) to reduce CO2, temp, or humidity.
  • Turn on an exhaust fan at night using a recycling timer, OR when Humidity is too high
    OR
  • Shut off a CO2 device when an exhaust fan is running
  • Shut off lights if the temperature gets too warm within the area

The DCC-1 is designed to be used in combination with one of TrolMaster’s plug-in style modules… the DSC-1, DSH-1&2, DST-1&2 and the DSP-1. Once the DCC-1 is connected to the plug-in DS module using an RJ12 cable, the DCC-1 will act in concert with that DS module to control whatever device is connected to the DS module.

Product Usage Instructions

To install the DCC-1

  1. First, you will plug the DS module into a power source near the equipment that will be controlled by the DS module.
  2. Connect a RJ12 cable from the DS module’s communication port to the female port on the DCC-1.
  3. Plug the DCC-1 into a splitter and RJ cable that is connected back to the Device port on the HCS-1.
    Note: The DCC-1 gets plugged inline with the DS modules RJ12 cable.
  4. Next you will select the desired mode on the DCC-1 by using the SET button to select the correct module type, and then pressing the Address button on the DCC-1. The DCC-1 is now connected to the HCS-1 and assigned as the device station you selected on the DCC1
  5. Go to the HCS-1 and find the device settings for the DCC-1.
  6. You can now change the settings for the DCC-1 module.
  7. If you have not already addressed the DS module that the DCC-1 is connected to, press the addressing button to address the DS module.
  8. Got to the HCS-1 and enter the settings for the DS module.
  9. The last thing to do is to decide whether or not to activate the interlock function or not.

Interlock Function

The DCC-1 can operate in two modes with the Interlock function:

  • Interlock ON: Both conditions must be activated together for device activation.
  • Interlock OFF: Either condition can activate the DS module individually.

To toggle between Interlock modes, press and hold the Interlock button for 3 seconds.

Specifications

  • Product Name: Trolmaster DCC-1
  • Function: Dual Condition Controller
  • Compatible Modules: DSC-1, DSH-1&2, DST-1&2, DSP-1
  • Communication: RJ12 cable

FAQS

Q: What modules are compatible with the DCC-1?

A: The DCC-1 is designed to work with TrolMaster's plug-in style modules such as DSC-1, DSH-1&2, DST-1&2, and DSP-1.

Q: How do I install the DCC-1?

A: Follow the installation steps provided in the user manual including connecting the DS module, setting modes, and adjusting settings on the HCS-1.

Q: How do I toggle between Interlock modes?

A: Press and hold the Interlock button on the DCC-1 for 3 seconds to switch between Interlock ON and OFF.

Q: Can I use the DCC-1 with multiple devices?

A: The DCC-1 can control multiple devices connected to compatible DS modules by following the installation and setup instructions.