Trikdis - logo

TRIKDIS - logo

NX-8V2
Wiring Trikdis GT+ Cellular Communicator and
Programming the Panel

CAUTION

  • The communicator should be installed and maintained by qualified personnel.
  •  Prior to installation, it is advised to read full device installation manual carefully in order to avoid mistakes that can lead to malfunction or even damage the equipment.
  • Disconnect the power supply before making any electrical connections.
  • Changes, modifications or repairs not authorized by the manufacturer shall void your rights under the warranty.

Schematics forwiring the communicator to the security control panel

Following the schematics provided below, wire the communicator to the control panel.

TRIKDIS NX 8V2 GT Cellular Communicator -

Programming the Interlogix NX-8V2 Alarm Panel via the LCD Keypad

Using the control panel’s keypad enter these sections and set them as described:
Enable Contact ID reporting

LCD keypad Keypad Entry Action Description
System ready *89713 Enter programming mode
Enter device address 0# To go to main panel programming menu
Enter location 4# To go to “Phone1 events reported” toggle menu.
Loc#4 Seg#1 12345678* All toggle options should be enabled. * to save and go to next menu.
Loc#4 Seg#2 12345678* All toggle options should be enabled. * to save and go back.
Enter location 23# To go to “Partition features” menu.
Loc#23 Seg#1 ** Press * twice to go to section 3 toggle options menu.
Loc#23 Seg#3 12345678*# Segment 3. All toggle options should be enabled, press * to save and then # to save and # to go back to the main menu.
Enter location 37# To go to “Siren and system supervision” menu.
Loc#37 Seg#1 ** Press * twice to go to segment 3 toggle options menu.
Loc#37 Seg#3 12345678* Segment 3. All toggle options should be enabled, press * to save.
Loc#37 Seg#4 12345678*# Segment 4. All toggle options should be enabled, press * to save and then # to save and # to go back to the main menu.
Enter location 90# To go to “Partition 2 features” menu.
Loc#90 Seg#1 ** Press * twice to go to section 3 toggle options menu.
Loc#90 Seg#3 12345678*# Segment 3. All toggle options should be enabled, press * to save and then # to save and # to go back to the main menu.
Enter location 93# To go to “Partition 3 features” menu.
Loc#93 Seg#1 ** Press * twice to go to section 3 toggle options menu.
Loc#93 Seg#3 12345678*# Segment 3. All toggle options should be enabled, press * to save and then # to save and # to go back to the main menu.

Programming the Interlogix NX-8V2 Alarm Panel via the LCD Keypad
Using the control panel’s keypad enter these sections and set them as described:
Enable Contact ID reporting

LCD keypad Keypad Entry Action Description
Enter location 96# To go to “Partition 4 features” menu.
Loc#96 Seg#1 ** Press * twice to go to section 3 toggle options menu.
Loc#96 Seg#3 12345678*# Segment 3. All toggle options should be enabled, press * to save and then # to save and # to go back to the main menu.
Enter location 99# To go to “Partition 5 features” menu.
Loc#99 Seg#1 ** Press * twice to go to section 3 toggle options menu.
Loc#99 Seg#3 12345678*# Segment 3. All toggle options should be enabled, press * to save and then # to save and # to go back to the main menu.
Enter location 102# To go to “Partition 6 features” menu.
Loc#102 Seg#1 ** Press * twice to go to section 3 toggle options menu.
Loc#102 Seg#3 12345678*# Segment 3. All toggle options should be enabled, press * to save and then # to save and # to go back to the main menu.
Enter location 105# To go to “Partition 7 features” menu.
Loc#105 Seg#1 ** Press * twice to go to section 3 toggle options menu.
Loc#105 Seg#3 12345678*# Segment 3. All toggle options should be enabled, press * to save and then # to save and # to go back to the main menu.
Enter location 108# To go to “Partition 8 features” menu.
Loc#108 Seg#1 ** Press * twice to go to section 3 toggle options menu.
Loc#108 Seg#3 12345678*# Segment 3. All toggle options should be enabled, press * to save and then # to save and # to go back to the main menu.
Enter location EXIT EXIT Press “EXIT” twice to exit programming mode.
LED keypad Keypad Entry Action Description
LEDs of Ready, Power steady ON *89713 Enter programming mode
Service LED blinks 0# To go to main panel programming menu
Service LED blinks, Armed LED steady ON 4# To go to “Phone1 events reported” toggle menu.
All zone LEDs are ON 12345678* All toggle options should be enabled. * to save and go to next

menu.

All zone LEDs are ON 12345678* All toggle options should be enabled. * to save and go back.
Service LED blinks, Armed LED steady ON 23# To go to “Partition feature and reporting selection” menu.
Service LED blinks, Ready LED steady ON ** Press * twice to go to segment 3 toggle options menu.
Service LED blinks, Ready LED steady ON 12345678*# Segment 3. All toggle options should be enabled, press * to save and then # to save and # to go back to the main menu.
Service LED blinks, Armed LED steady ON 37# To go to “Siren and system supervision” menu.
Service LED blinks, Ready LED steady ON ** Press * twice to go to segment 3 toggle options menu.
Service LED blinks, Ready LED steady ON 12345678* Segment 3. All toggle options should be enabled, press * to save.
Service LED blinks, Ready LED steady ON 12345678*# Segment 4. All toggle options should be enabled, press * to save and then # to save and # to go back to the main menu.
Service LED blinks, Armed LED steady ON 90# To go to “Partition 2 feature and reporting selection” menu.
Service LED blinks, Ready LED steady ON ** Press * twice to go to segment 3 toggle options menu.
Service LED blinks, Ready LED steady ON 12345678*# Segment 3. All toggle options should be enabled, press * to save and then # to save and # to go back to the main menu.
Service LED blinks, Armed LED steady ON 93# To go to “Partition 3 feature and reporting selection” menu.
Service LED blinks, Ready LED steady ON ** Press * twice to go to segment 3 toggle options menu.
Service LED blinks, Ready LED steady ON 12345678*# Segment 3. All toggle options should be enabled, press * to save and then # to save and # to go back to the main menu.
LED keypad Keypad Entry Action Description
Service LED blinks, Armed LED steady ON 96# To go to “Partition 4 feature and reporting selection” menu.
Service LED blinks, Ready LED steady ON ** Press * twice to go to segment 3 toggle options menu.
Service LED blinks, Ready LED steady ON 12345678*# Segment 3. All toggle options should be enabled, press * to save and then # to save and # to go back to the main menu.
Service LED blinks, Armed LED steady ON 99# To go to “Partition 5 feature and reporting selection” menu.
Service LED blinks, Ready LED steady ON ** Press * twice to go to segment 3 toggle options menu.
Service LED blinks, Ready LED steady ON 12345678*# Segment 3. All toggle options should be enabled, press * to save and then # to save and # to go back to the main menu.
Service LED blinks, Armed LED steady ON 102# To go to “Partition 6 feature and reporting selection” menu.
Service LED blinks, Ready LED steady ON ** Press * twice to go to segment 3 toggle options menu.
Service LED blinks, Ready LED steady ON 12345678*# Segment 3. All toggle options should be enabled, press * to save and then # to save and # to go back to the main menu.
Service LED blinks, Armed LED steady ON 105# To go to “Partition 7 feature and reporting selection” menu.
Service LED blinks, Ready LED steady ON ** Press * twice to go to segment 3 toggle options menu.
Service LED blinks, Ready LED steady ON 12345678*# Segment 3. All toggle options should be enabled, press * to save and then # to save and # to go back to the main menu.
Service LED blinks, Armed LED steady ON 108# To go to “Partition 8 feature and reporting selection” menu.
Service LED blinks, Ready LED steady ON ** Press * twice to go to segment 3 toggle options menu.
Service LED blinks, Ready LED steady ON 12345678*# Segment 3. All toggle options should be enabled, press * to save and then # to save and # to go back to the main menu.
Service LED blinks, Armed LED steady ON EXIT EXIT Press “EXIT” twice to exit programming mode.

LED indication of communicator operation

Indicator Light status Description
 

NETWORK

Off No connection to cellular network
Yellow blinking Connecting to cellular network
Green solid with yellow blinking Communicator is connected to cellular network. Yellow blinks count indicates signal strength, 10 blinks max. Sufficient cellular signal strength for 4G network – level 3 (three yellow flashes).
 

DATA

Off No unsent events
Green solid Unsent events are stored in buffer
Green blinking (Configuration mode) Data is being transferred to/from communicator
 

 

POWER

Off Power supply is off or disconnected
Green solid Power supply is on with sufficient voltage
Yellow solid Power supply voltage is insufficient (≤11.5V)
Green solid and yellow blinking Configuration mode) Communicator is ready for configuration
Yellow solid (Configuration mode) No connection with computer
 

 

 

 

 

TROUBLE

Off No operation problems
1 red blink SIM card not found
2 red blinks SIM card PIN code problem (incorrect PIN code)
3 red blinks Programming problem (No APN)
4 red blinks Registration to GSM network problem
5 red blinks Registration to GPRS/UMTS network problem
6 red blinks No connection with the receiver
7 red blinks Lost connection with control panel
8 red blinks The entered ICCID number does not match the ICCID number of the SIM card
Red blinking (Configuration mode) Memory fault
Red solid (Configuration mode) Firmware is corrupted
 

 

BAND

1 green blink None
2 green blinks GSM
3 green blinks GPRS
4 green blinks EDGE
5 green blinks HSDPA, HSUPA, HSPA+, WCDMA
6 green blinks LTE TDD, LTE FDD

Setting up the GT+ communicator with the app

Download and launch the Protegus application or use the browser version: web.protegus.app.
The installer must connect to Protegus with an installer account.

TRIKDIS NX 8V2 GT Cellular Communicator - figer

TRIKDIS NX 8V2 GT Cellular Communicator - figer2

After completing the setup and installation perform a system check:

  1. Create an event:
    – by arming/disarming the system with the control panel’s keypad;
    – by triggering a zone alarm when the security system is armed.
  2. Make sure that the event arrives to the CMS (Central Monitoring Station) and the Protegus app.

trikdis.com

Documents / Resources

TRIKDIS NX-8V2 GT+ Cellular Communicator [pdf] Owner's Manual
NX-8V2 GT Cellular Communicator, NX-8V2, GT Cellular Communicator, Cellular Communicator, Communicator

References

Leave a comment

Your email address will not be published. Required fields are marked *