Watt 0063010

Watts 009M2 Azaltılmış Basınç Bölgesi Geri Akış Önleyici (Model 0063010) Kullanım Kılavuzu

For Models: 009M2, 009M2-QT

1. Giriş

This manual provides detailed instructions for the installation, operation, and maintenance of the Watts 009M2 Reduced Pressure Zone (RPZ) Backflow Preventer. This device is designed to protect potable water supplies from contamination due to backpressure or backsiphonage from non-potable sources. It is crucial to read and understand all instructions before installation and use to ensure proper function and safety.

The Watts 009M2 RPZ assembly features a compact, modular design for easy maintenance, with a single access cover for in-line repairs. It is suitable for continuous pressure piping applications and cross-connections identified as health hazards.

2. Önemli Güvenlik Bilgileri

3. Ürün Bittiview ve Bileşenler

The Watts 009M2 Reduced Pressure Zone Backflow Preventer is constructed with a durable bronze body and features NPT end connections. Key components include:

Watts 009M2 Reduced Pressure Zone Backflow Preventer
Figure 1: Watts 009M2 Reduced Pressure Zone Backflow Preventer. This image shows the bronze body, quarter-turn shutoff valves with green handles, and multiple test cocks on top.

4. Kurulum ve Kurulum

  1. Kurulum Öncesi Kontrol:
    • Verify that the product model (009M2) and size (2 inch) match your requirements.
    • Üründe nakliye kaynaklı herhangi bir hasar olup olmadığını kontrol edin.
    • Ensure all necessary tools and materials for installation are available.
  2. Saha Hazırlığı:
    • Choose an installation location that allows for easy access for testing and maintenance.
    • Ensure adequate drainage for the relief valve discharge.
    • The device should be installed horizontally, with the relief valve pointing downwards.
  3. Boru Bağlantısı:
    • Flush the upstream piping thoroughly to remove any debris before connecting the backflow preventer.
    • Connect the inlet and outlet piping to the NPT connections on the device. Use appropriate thread sealant.
    • Avoid overtightening connections to prevent damage to the bronze body.
    • Ensure the flow arrow on the device body matches the direction of water flow.
  4. Relief Valve Drain:
    • Connect a drain line to the relief valve outlet. The drain line must be adequately sized and sloped to allow for free discharge and prevent backpressure on the relief valve.
    • Ensure the drain line terminates in an air gap, preventing any possibility of cross-connection.
  5. Kurulum Sonrası Kontrol:
    • Slowly open the upstream shutoff valve, then the downstream shutoff valve, to gradually fill the system and prevent water hammer.
    • Tüm bağlantılarda sızıntı olup olmadığını inceleyin.
    • Perform initial testing by a certified backflow prevention tester to ensure proper operation and compliance with local codes.

5. Kullanım Talimatları

The Watts 009M2 is designed for continuous pressure operation. Normal operation involves the device being fully open, allowing water to flow through the system while providing backflow protection.

6. Bakım

Regular maintenance is critical for the reliable performance of your backflow preventer. The modular design and single access cover simplify servicing.

7. Sorun Giderme

SorunOlası NedenÇözüm
Water discharge from relief valve (continuous)
  • Fouled first check valve
  • Damaged relief valve seat or disc
  • Excessive backpressure
  • Clean or repair first check valve.
  • Inspect and replace relief valve components.
  • Identify and correct source of backpressure.
Su akışı yok veya azalmış durumda.
  • Shutoff valves closed
  • Debris obstructing flow
  • Fouled check valves
  • Ensure shutoff valves are fully open.
  • Isolate and inspect for debris.
  • Clean or repair check valves.
Bağlantılardan kaynaklanan sızıntılar
  • Improperly sealed threads
  • Hasarlı contalar
  • Re-apply thread sealant and tighten connections.
  • Inspect and replace gaskets.

For issues not listed or if troubleshooting steps do not resolve the problem, contact a certified plumbing professional or Watts technical support.

8. Özellikler

Model Numarası0063010 (009M2)
Backflow Preventer TypeAzaltılmış Basınç Bölgesi Montajı
Gövde MalzemesiBronz
Giriş/Çıkış Bağlantı Boyutu2 Inches (50 MM)
Inlet/Outlet Connection TypeFemale Threaded NPT
Maksimum Çalışma Basıncı175 PSI (12.10 BAR)
Maksimum Sıcaklık180°F (82°C)
asgari Sıcaklık33°F (0.5°C)
Koruma TürüBackpressure and Backsiphonage
Ürün Boyutları (U x G x Y)22 x 10 x 8 inç
Ürün Ağırlığı27 Pound
Lead Free StatusNO (For non-potable use only)

9. Garanti ve Destek

Specific warranty information for Watts products is typically provided with the product packaging or available on the official Watts webLütfen en güncel garanti şartları ve koşulları için bu kaynaklara bakın.

For technical support, replacement parts, or further assistance, please contact Watts customer service or visit their official website. Ensure you have your product model number (0063010) and serial number (if applicable) ready when contacting support.

Watts Official Webalan: www.watt.com

İlgili Belgeler - 0063010

Önview Watts LF909 Series Reduced Pressure Zone Assembly Engineering Specification
Comprehensive engineering specification for the Watts LF909 Series Reduced Pressure Zone Assembly (21⁄2" - 10"). Details features, operation, materials, dimensions, and capacity for this Lead Free backflow prevention device with integrated flood sensor.
Önview Watts Series 009, LF009, LFU009, SS009, U009: Installation, Maintenance, and Repair Manual
This comprehensive manual from Watts provides essential guidance for the installation, maintenance, and repair of the Series 009, LF009, LFU009, SS009, and U009 Reduced Pressure Zone Assemblies. It details safety warnings, installation procedures, inspection, servicing, troubleshooting, and warranty information for these critical backflow prevention devices.
Önview Watts Series 909, LF909, 909RPDA Reduced Pressure Zone Assemblies Installation, Maintenance, and Repair Manual
Comprehensive guide for the installation, maintenance, and repair of Watts Series 909, LF909, and 909RPDA Reduced Pressure Zone Assemblies, including safety warnings, installation guidelines, testing procedures, servicing instructions, troubleshooting, and warranty information.
Önview Watts LF909 Serisi Düşük Basınçlı Bölge Montajları - Teknik Özellikler
Watts LF909 Serisi Düşük Basınç Bölgesi Tertibatlarının özellikleri, çalışma prensibi, boyutları, ağırlıkları ve kapasitesi dahil olmak üzere ayrıntılı teknik özellikleri. İçme suyu çapraz bağlantı kontrolü için tasarlanmıştır.
Önview Watts Serisi 009, LF009, LFU009, SS009, U009 Düşük Basınçlı Bölge Tertibatları Kurulum, Bakım ve Onarım Kılavuzu
Watts Serisi 009, LF009, LFU009, SS009 ve U009 Azaltılmış Basınç Bölgesi Montajlarının kurulumu, bakımı ve onarımı için kapsamlı kılavuz; güvenlik, kurulum prosedürleri, yıllık kontrol, sorun giderme ve servis konularını kapsar. Su baskını sensörü aktivasyonu ve bağlantı kitleri hakkında ayrıntılı bilgi içerir.
Önview Watts Series LF919 Reduced Pressure Zone Assembly: Installation, Maintenance, and Repair Manual
Comprehensive guide for installing, maintaining, and repairing the Watts Series LF919 Reduced Pressure Zone Assembly (1/2" - 2"). Includes safety warnings, installation procedures, servicing instructions, and troubleshooting.