LED Explanation 

LED Explanation
PWR On/Off: Power on/off
SYS Blinking: System running normally
On/Off: System running abnormally
Link/Act
(For Ports 1-5)
On (Green) : Running at 1000 Mbps
On (Yellow): Running at 10/100 Mbps
Blinking: Transmitting/receiving data
Off: No connected device
PoE Status
(For Ports 1-4)
On: Providing PoE power
Blinking: Current-overload/Short-circuit
Off: No PD device or PoE Power not provided
PoE Max On: 56 W ≤ Total power supply < 63 W
Blinking: Total power supply remains ;:: 56 W
for more than 2 minutes
Off: Total power supply< 56 W
SFP
(For Port 6)
On (Green): Running at 1000 Mbps
On (Yellow): Running at 100 Mbps
Blinking: Transmitting/receiving data
Off: No connected device

Package Contents

tp-link SG2206MP Omada Access Switch - Package Contents

Installation

Option 1: Desktop Installation
Attach the supplied rubber feet to the bottom of the switch to prevent it from slipping when placed on a desktop.tp-link SG2206MP Omada Access Switch - Desktop InstallationNote:
Avoid placing the switch on top of another and use the rubber feet to ensure enough clearance for air circulation.
Option 2: Wall-Mounting Installation
Drill two holes in the wall aligned with the switch’s mounting holes, then secure it using two appropriate screws (not provided) .tp-link SG2206MP Omada Access Switch - appropriate screwsNote:
Ensure enough clearance between the switch and the wall for air circulation.
For detailed information, refer to the Wall Mounting Guide at https://support.omadanetworks.com/document/901/.

Connection

Note: For simplic ity, this guide will use SG2206MP as an example throughout. tp-link SG2206MP Omada Access Switch - ConnectionNote:

  1. PoE ports can also connect to non-PoE devices, but only transmit data.
  2. The PoE ports shall not be used to charge lithium batteries or devices supplied by lithium batteries.
  3. PoE budget calculations are based on laboratory testing. Actual PoE power budget is not guaranteed and will vary as a result of client limitations and environmental factors.

Environmental and Physical Specifications 

Operating Temperature -5 ·c to 4o·c (23″Fto 104″ Fl
Storage Temperature -40 “C to 70 “C (-40″ F to 158” F)
Operating Humidity 10% to 90%RH non-condensing
Storage Humidity 5% to 90%RH non-condensing

More Resources

Main Site https://www.omadanetworks.com/
Video Center https://support.omadanetworks.com/video/
Documents https://support.omadanetworks.com/document/
Product Support https://support.omadanetworks.com/product/
Technical Support https://support.omadanetworks.com/contact-support/

Configuration

The switch supports two configuration methods:

  • Standalone Mode
    Configure and manage the switch individually .
    To set up a standalone Omada switch, scan the QR code or refer to https://www.omadanetworks.com/support/faq/4097/.tp-link SG2206MP Omada Access Switch - QR CODE 1
  • Controller Mode
    Configure and manage the network devices centrally .
    This mode is recommended for large-scale networks with numerous devices, including access points, switches, and gateways.
    To set up an Omada switch with an Omada Controller, scan the QR code or refer to the Omada Controller configuration guide at https://www.omadanetworks.com/support/faq/4096/.tp-link SG2206MP Omada Access Switch - QR CODE 2

OmadaApp
With the TP-Link Omada app, you can access and manage your Omada devices at a local site or remotely with a tap of your phone. You can download and install the TP-Link Omada app from the App Store or Google Play.

tp-link SG2206MP Omada Access Switch - QR CODE 3https://www.tp-link.com/common/app/omada/qrcode.php

For detailed instructions on device configuration, refer to the user guides of the Controller and switches. The guides can be found in the Documents Center of our official website: https://support.omadanetworks.com/document/.

Warranty
For details on the warranty period, policy, and procedures, visit https://support.omadanetworks.com/warranty-services .
Support
For technical support, user guides and other information, please visit https://support.omadanetworks.com/, or simply scan the QR code.

tp-link SG2206MP Omada Access Switch - QR CODE 4

Safety Information

  • Keep the device away from water, fire, humidity or hot environments.
  • Do not attempt to disassemble, repair, or modify the device. If you need service, please contact us.
  • Do not use damaged charger or USB cable to charge the device.
  • Do not use any other chargers than those recommended.
  • Adapter shall be in stalled near the equipment and shall be easily accessible.
  • Use only power supplies which are provided by manufacturer and in the origin packing of this product. If you have any questions, please don’t hesit ate to contact us.
  • Pl ace the device with its bottom surface downward.
  • The PoE ports shall not be used to charge lithium batteries or devices supplied by lithium batteries.

FCC Compliance Information Statement

tp-link SG2206MP Omada Access Switch - Symbol
Product Name: Omada 6-Port Gigabit Access Switch with 4-Port PoE+
Model Number: SG2206MP

Component Name Model
Power Adapter T535131-2-DT

Responsible party:
TP-Link Systems Inc.
Address: 10 Mauchly, Irvine, CA 92618
Website: https://www.tp-link.com/us/
Tel: +1 626 333 0234
Fax: +1 909 527 6804
E-mail: sales.usa@tp-link.com
This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment.
This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense.
This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions:

  1. This device may not cause harmful interference.
  2. This device must accept any interference received, including interference that may cause undesired operation.

Any changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment.
Product Name: Power Adapter
Model Number: T535131-2-DT
Responsible party:
TP-Link Systems Inc.
Address: 10 Mauchly, Irvine, CA 92618
Website: https://www.tp-link.com/us/
Tel: +1 626 333 0234
Fax: +1 909 527 6804
E-mail: sales.usa@tp-link.com

This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment.
This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense.
We, TP-Link Systems Inc., has determined that the equipment shown as above has been shown to comply with the applicable technical standards, FCC part 15. There is no unauthorized change is made in the equipment and the equipment is properly maintained and operated.
Issue Date: 2025/02/11

CE Mark Warning
CE SYMBOL
This is a class A product. In a domestic environment, this product may cause radio interference, in which case the user may be required to take adequate measures.
TP-Link hereby declares that the switch is in compliance with the essential requirements and other relevant provisions of directives 2014/30/EU, 2014/35/EU, 2011/65/EU and (EU)2015/863.
The original EU declaration of conformity may be found at https://www.tp-link.com/en/ce
UKCA Mark Warning
tp-link SG2206MP Omada Access Switch - Symbol 1
TP-Link hereby declares that the switch is in compliance with the essential requirements and other relevant provisions of the Electromagnetic Compatibility Regulations 2016 and Electrical Equipment (Safety) Regulations 2016.
The original UK declaration of conformity may be found at https://www.tp-link.com/support/ukca/
Industry Canada Statement
CAN ICES-3 (A)/NMB-3(A)

tp-link SG2206MP Omada Access Switch - Symbol 2
Safety Information

  • Do not attempt to disassemble, repair, or modify the device. If you need service, please contact us.
  • Keep the device away from water, fire, humidity or hot environments.
  • Place the device with its bottom surface downward.
  • Do not use damaged charger or USB cable to charge the device.
  • Do not use any other chargers than those recommended.
  • Adapter shall be installed near the equipment and shall be easily accessible.
  • Use only power supplies which are provided by manufacturer and in the original packing of this product. If you have any questions, please don’ t hesitate to contact us.
  • The PoE ports shall not be used to charge lithium batteries or devices supplied by lithium batteries.
  • The operating temperature for the device shall be within -5˚C to 40˚C (23˚F to 104˚F).
  • The operating temperature for the power adapter shall be within 0˚C to 40˚C (32˚F to 104˚F).

Please read and follow the above safety information when operating the device. We cannot guarantee that no accidents or damage will occur due to improper use of the device. Please use this product with care and operate at your own risk.

Explanation of the symbols on the product label
Note: The product label can be found at the bottom of the product and its I.T.E. power supply.
Symbols may vary from products.

Symbol Explanation
tp-link SG2206MP Omada Access Switch - Symbol 3 Class II equipment
tp-link SG2206MP Omada Access Switch - Symbol 4 Class II equipment with functional earthing
tp-link SG2206MP Omada Access Switch - Symbol 5 Alternating current
Direct current
tp-link SG2206MP Omada Access Switch - Symbol 6 Polarity of d.c. power connector
tp-link SG2206MP Omada Access Switch - Symbol 7 For indoor use only
tp-link SG2206MP Omada Access Switch - Symbol 8 Dangerous voltage
tp-link SG2206MP Omada Access Switch - Symbol 9 Caution, risk of electric shock
tp-link SG2206MP Omada Access Switch - Symbol 10 Energy efficiency Marking
tp-link SG2206MP Omada Access Switch - Symbol 11 Protective earth
tp-link SG2206MP Omada Access Switch - Symbol 12 Earth
tp-link SG2206MP Omada Access Switch - Symbol 13 Frame or chassis
tp-link SG2206MP Omada Access Switch - Symbol 14 Functional earthing
tp-link SG2206MP Omada Access Switch - Symbol 15 Caution, hot surface
Warning icon Caution
tp-link SG2206MP Omada Access Switch - Symbol 16 Operator’s manual
tp-link SG2206MP Omada Access Switch - Symbol 17 Stand-by
tp-link SG2206MP Omada Access Switch - Symbol 18 “ON”/”OFF” (push-push)
tp-link SG2206MP Omada Access Switch - Symbol 19 Fuse
tp-link SG2206MP Omada Access Switch - Symbol 20 Fuse is used in neutral N
WEE-Disposal-icon.png RECYCLING

This product bears the selective sorting symbol for Waste electrical and electronic equipment (WEEE). This means that this product must be handled pursuant to European directive 2012/19/EU in order to be recycled or dismantled to minimize its impact on the environment.
User has the choice to give his product to a competent recycling
organization or to the retailer when he buys a new electrical or
electronic equipment.
tp-link SG2206MP Omada Access Switch - Symbol 21 Caution, avoid listening at high volume levels for long periods
tp-link SG2206MP Omada Access Switch - Symbol 22 Disconnection, all power plugs
tp-link SG2206MP Omada Access Switch - Symbol 23 Switch of mini-gap construction
tp-link SG2206MP Omada Access Switch - Symbol 24 Switch of micro-gap construction (for US version)
Switch of micro-gap / micro-disconnection construction (for other
versions except US)
tp-link SG2206MP Omada Access Switch - Symbol 25 Switch without contact gap (Semiconductor switching device)

Wall Mounting Requirements
To mount the device on a wall, use 2 screws which complies with ANSI B1.1 4#, (5#), 6#, 8# standard and are more than 8.5 mm in length. When the screws are fixed on the wall, the distance between the screw head and the wall should be more than 1.5 mm.

tp-link logo

Documents / Resources

tp-link SG2206MP Omada Access Switch [pdf] Installation Guide
SG2206MP UN, SG2206MP Omada Access Switch, SG2206MP, Omada Access Switch, Access Switch, Switch

References

Leave a comment

Your email address will not be published. Required fields are marked *