tp-link OC200 Hardware Controller

Specifications
- Model: Omada Hardware Controller
- Power Input: Standard PoE or USB Power Source (5 VDC, minimum 1 A)
- Ports: ETH1 (PoE IN), ETH2, USB 2.0, Micro USB
- LED Indicators: Cloud LED, Power LED
- Security Features: Kensington Security Slot
Product Usage Instructions
Package Contents:
Ensure you have received the following items:
- Omada Hardware Controller
- Rubber Feet
- Ethernet Cable
- Installation Guide
Hardware Overview:
Learn about the front and rear panel components and their functions.
Front Panel:
Includes Cloud LED, Power LED, ETH1 (PoE IN) port, ETH2 port, USB 2.0 port, and reset button. Refer to the manual for LED status indications.
Rear Panel:
Features a Kensington Security Slot and a Micro USB port for power supply.
Installation:
Choose between Desktop or Wall Mounting installation methods.
Desktop Installation:
- Place the device on a flat surface.
- Attach the rubber feet to prevent slipping.
Wall Mounting:
Drill holes on the wall and secure the controller with screws.
Power On:
Power the device using either a Standard PoE device or a USB Power Source.
Typical Network Topology:
Ensure a DHCP server is available to assign IP addresses to the connected devices.\
Thank you for purchasing the Omada Hardware Controller. This Installation Guide is designed to guide you through the installation.
Note: Images may differ from the actual product.
Package Contents

Hardware Overview
Front Panel

Cloud LED
- On: The device is bound to a TP-Link ID.
- Flashing Slowly: The device is connected to the cloud but not bound to a TP-Link ID.
- Flashing Quickly: The device is being reset to its factory default settings.
- Off: The device is disconnected from the cloud.
Power LED
- On: Working normally.
- Off: Working abnormally.
- Link/Act
- Solid Green: Running at 1000 Mbps, but no activity.
- Flashing Green: Running at 1000 Mbps and transmitting or receiving data.
- Solid Amber: Running at 100/10 Mbps, but no activity. Flashing Amber: Running at 100/10 Mbps and transmitting or receiving data.
- Off: No device is linked to the corresponding port.
- ETH1 (PoE IN) Port
Connect to a standard 802.3af/at PoE device, such as a TP-Link PoE switch, for simultaneous data transmission and power supply. - ETH2 Port
Connect to a device to transmit data. - USB 2.0 Port
Connect to a storage device to back up the configuration file and database. This port is available only when the controller is powered by a PoE device. - Reset Button
After the device is initialized, press and hold the button for 5 seconds to reset the device to its factory default settings.
Rear Panel

- Kensington Security Slot
Secure the lock (not provided) into the security slot to prevent the device from being stolen. - Micro USB
Connect to a USB Power Source (5 VDC, minimum 1 A) for power supply if PoE is unavailable.
Installation
Desktop
- Set the device on a flat surface to support the entire weight of the device with all fittings.
- Remove the adhesive backing papers from the rubber feet.
- Turn the device over and attach the supplied rubber feet to the recessed areas on the bottom at each corner of the device to prevent it from slipping when placed on a desktop.

Wall Mounting
- Drill two holes in the wall according to the mounting holes on the bottom of the controller.
- Secure the controller to the wall with two suitable screws (not provided).

Power On
Via Standard PoE Device
Connect an Ethernet cable from the ETH1 (PoE IN) port to a standard 802.3af/at PoE device, such as a TP-Link PoE switch. Make sure your power supply matches your device.

Via USB Power Source
Connect a USB cable (not provided) from the micro USB port to the USB Power Source (5 VDC, minimum 1 A).

The Cloud LED flashes three times when initialization is finished.
Typical Network Topology
A DHCP server (typically a router/gateway) with the DHCP function enabled is required to assign IP addresses to the EAPs and OC220 in your local network.

Software Configurations
The Omada Hardware Controller supports two management options:
- Remote Management: configure and manage via cloud access
- Local Management: configure and manage locally
Remote Management
Via Omada App
- Make sure that your mobile device and OC220 can access the internet.
- Download the Omada App on your mobile device. It can be downloaded from the App Store or Google Play:

- Launch the app and go to Controller Mode. Then, log in with your TP-Link ID.
- Tap the + button in the upper-right corner, select On-Premises Controller to add OC220, and follow the step-by-step instructions to complete the quick setup. Alternatively, you can add the controller by scanning the device key printed on the product label.
Via Web Browser
- Make sure that your management device and OC220 can access the internet.
- Launch a web browser and type https://omada.tplinkcloud.com in the address bar, then press Enter (Windows) or Return (Mac).

- Enter your TP-Link ID and password to log in.
- Click On-Premise Systems, then click + Add and choose Hardware Controller to add your controller.
- Follow the step-by-step instructions to complete the configuration wizard.
Local Management
Omada
- Download the Omada app on your mobile device. It can be downloaded from the App Store or Google Play:

- Make sure that your mobile device and OC220 are on the same subnet.
- Launch the app and go to Controller Mode. Then, tap the + button in the upper-right corner to add OC220.
- Choose the auto-detected device or manually add your device by entering its IP address/URL and port number. Follow the step-by-step instructions to complete the quick setup.
Via Web Browser
- Make sure that your management device and OC220 are on the same subnet.
- Check the DHCP server (typically a router) for OC220’s IP Address. The default fallback IP address is 192.168.0.253.
- If you have downloaded the Omada app, you can also check the app for OC220’s IP address.
- The fallback IP address is used when OC220 fails to obtain a dynamic IP from the DHCP server.
- Launch a web browser and type OC220’s IP address in the address bar, then press Enter (Windows) or Return (Mac).

- Click Let’s Get Started and follow the step-by-step instructions to complete the configuration wizard.
More Resources
| Main Site | https://www.omadanetworks.com |
| Video Center | https://support.omadanetworks.com/video |
| Documents | https://support.omadanetworks.com/document |
| Product Support | https://support.omadanetworks.com/product |
| Technical Support | https://support.omadanetworks.com/contact-support |
Warranty
For details on the warranty period, policy, and procedures, visit https://support.omadanetworks.com/warranty-services.
Support
For technical support, user guides, and other information, please visit https://support.omadanetworks.com or simply scan the QR code.

- TP-Link hereby declares that the device is in compliance with the essential requirements and other relevant provisions of directives 2014/30/EU, 2014/35/EU, 2009/125/EC, 2011/65/EU and (EU)2015/863.
- The original EU declaration of conformity may be found at https://www.tp-link.com/en/ce.
- TP-Link hereby declares that the device is in compliance with the essential requirements and other relevant provisions of the Electromagnetic Compatibility Regulations 2016 and Electrical Equipment (Safety) Regulations 2016.
- The original UK Declaration of Conformity may be found at https://www.tp-link.com/sup-port/ukca.
Safety Information
- Keep the device away from water, fire, humidity, or hot environments.
- Do not attempt to disassemble, repair, or modify the device. If you need service, please get in touch with us.
- The plug on the power supply cord is used as the disconnect device, the socket-outlet shall be easily accessible.
- The power source should meet PS2 and other requirements according to IEC 62368-1.
©2025 TP-Link 7106512014 REV1.0.0
Frequently Asked Questions
- Q: What should I do if the Cloud LED is flashing quickly?
A: This indicates that the device is being reset to its factory default settings. Wait for the process to complete. - Q: Can I use any USB cable to connect to the USB Power Source?
A: No, Ensure you use a cable that meets the minimum requirements of 5 VDC and 1 A for proper power supply.
Documents / Resources
![]() | OC200 Hardware Controller |
References
- omada.tplinkcloud.comomada.tplinkcloud.com
- Omada Network Supportsupport.omadanetworks.com
- Call Support | Omada Network Supportsupport.omadanetworks.com
- Documents | Omada Network Supportsupport.omadanetworks.com
- Product Support | Omada Network Supportsupport.omadanetworks.com
- Video Center | Omada Network Supportsupport.omadanetworks.com
- Warranty Services | Omada Network Supportsupport.omadanetworks.com
- Omada - Networks Empower Business | TP-Linkwww.omadanetworks.com
- CE Regulatory Compliance | TP-Linkwww.tp-link.com
- User Manualmanual.tools