tp link- logoEthernet Switch (48-port
Managed Switch)
Quick Start Guidetp link 48P Port Managed Switch-

V1.0.2

Foreword

General
This manual introduces the installation, functions and operations of the 48-port Managed Switch (hereinafter referred to as “the device”). Read carefully before using the device, and keep the manual safe for future reference.
Safety Instructions
The following signal words might appear in the manual.

Signal Words

Meaning

tp link 48P Port Managed Switch- icon Indicates a high potential hazard which, if not avoided, will result in death or serious injury.
tp link 48P Port Managed Switch- icon1 Indicates a medium or low potential hazard which, if not avoided, could result in slight or moderate injury.
tp link 48P Port Managed Switch- icon2 Indicates a potential risk which, if not avoided, could result in property damage, data loss, lower performance, or unpredictable result.
tp link 48P Port Managed Switch- icon3 Provides methods to help you solve a problem or save you time.
tp link 48P Port Managed Switch- icon4 Provides additional information as the emphasis and supplement to the text.

Revision History

Version Revision Content

Release Time

V1.0.2 ●  Updated the important safeguard and warnings.
●  Updated the console port.
June 2025
V1.0.1 Updated the front panel. August 2023
V1.0.0 First release. August 2023

About the Manual

  • The manual is for reference only. Slight differences might be found between the manual and the product.
  • We are not liable for losses incurred due to operating the product in ways that are not in compliance with the manual.
  • The manual will be updated according to the latest laws and regulations of related jurisdictions. For detailed information, see the paper user manual, use our CD-ROM, scan the QR code or visit our official website. The manual is for reference only. Slight differences might be found between the electronic version and the paper version.
  • All designs and software are subject to change without prior written notice. Product updates might result in some differences appearing between the actual product and the manual. Please contact customer service for the latest program and supplementary documentation.
  • There might be errors in the print or deviations in the description of the functions, operations and technical data. If there is any doubt or dispute, we reserve the right of final explanation.
  • Upgrade the reader software or try other mainstream reader software if the manual (in PDF format) cannot be opened.
  • All trademarks, registered trademarks and company names in the manual are properties of their respective owners.
  • Please visit our website, contact the supplier or customer service if any problems occur while using the device.
  • If there is any uncertainty or controversy, we reserve the right of final explanation.

Important Safeguard and Warnings

This section introduces content covering the proper handling of the device, hazard prevention, and prevention of property damage. Read carefully before using the device, and comply with the guidelines when using it.

Transportation Requirements
Warning icon Transport the device under allowed humidity and temperature conditions.
Storage Requirements
Warning icon Store the device under allowed humidity and temperature conditions.
Installation Requirements

tp link 48P Port Managed Switch- icon

Stability Hazard
Possible result: The device might fall down and cause serious personal injury.
Preventive measures (including but not limited to):

  • Before extending the rack to the installation position, read the installation instructions.
  • When the device is installed on the slide rail, do not place any load on it.
  • Do not retract the slide rail while the device is installed on it.

tp link 48P Port Managed Switch- icon1

  • Do not connect the power adapter to the device while the adapter is powered on.
  • Strictly comply with the local electrical safety code and standards. Make sure that the ambient voltage is stable and meets the power supply requirements of the device.
  • Personnel working at heights must take all necessary measures to ensure personal safety including wearing a helmet and safety belts.
  • Please follow the electrical requirements to power the device.
    Following are the requirements for selecting a power adapter.
    ○ The power supply must conform to the requirements of IEC 60950-1 and IEC 62368-1 standards.
    ○ The voltage must meet the SELV (Safety Extra Low Voltage) requirements and not exceed ES-1 standards.
    ○ When the power of the device does not exceed 100 W, the power supply must meet LPS requirements and be no higher than PS2.
    ◆ We recommend using the power adapter provided with the device.
    ◆  When selecting the power adapter, the power supply requirements (such as rated voltage) are subject to the device label.
  • Warning icon Do not place the device in a place exposed to sunlight or near heat sources.
  • Keep the device away from dampness, dust, and soot.
  • Put the device in a well-ventilated place, and do not block its ventilation.
  • Use an adapter or cabinet power supply provided by the manufacturer.
  •  Do not connect the device to two or more kinds of power supplies, to avoid damage to the device.
  • The device is a class I electrical appliance. Make sure that the power supply of the device is connected to a power socket with protective earthing.
  • When installing the device, make sure that the power plug can be easily reached to cut off the power.
  • Voltage stabilizer and lightning surge protector are optional depending on the actual power supply on site and the ambient environment.
  • To ensure heat dissipation, the gap between the device and the surrounding area should not be less than 10 cm on the sides and 10 cm on top of the device.
  • When installing the device, make sure that the power plug and appliance coupler can be easily reached to cut off power.

Operating Requirements

tp link 48P Port Managed Switch- icon

  • tp link 48P Port Managed Switch- icon5 The device or remote control contains button batteries. Do not swallow the batteries due to the risk of chemical burns.
    Possible result: The swallowed button battery can cause serious internal burns and death within 2 hours.
    Preventive measures (including but not limited to):
    ◆ Keep new and used batteries out of reach of children.
    ◆ If the battery compartment is not securely closed, stop using the product immediately and keep out of reach of children.
    ◆ Seek immediate medical attention if a battery is believed to be swallowed or inserted inside any part of the body.
  • Battery Pack Precautions
    Preventive measures (including but not limited to):
    ◆ Do not transport, store or use the batteries in high altitudes with low pressure and environments with extremely high and low temperatures.
    ◆ Do not dispose the batteries in fire or a hot oven, or mechanically crush or cut the batteries to avoid an explosion.
    ◆ Do not leave the batteries in environments with extremely high temperatures to avoid explosions and leakage of flammable liquid or gas.
    ◆ Do not subject the batteries to extremely low air pressure to avoid explosions and the leakage of flammable liquid or gas.

tp link 48P Port Managed Switch- icon1

  • Operating the device in a domestic environment may cause radio interference.
  • Place the device in a location that children cannot easily access.
  • Do not disassemble the device without professional instruction.
  • Operate the device within the rated range of power input and output.
  • Make sure that the power supply is correct before use.
  • Make sure the device is powered off before disassembling wires to avoid personal injury.
  • Do not unplug the power cord on the side of the device while the adapter is powered on.
  • Ground the device to protective ground before you power it on.
  • Warning icon Use the device under allowed humidity and temperature conditions.
  • Do not drop or splash liquid onto the device, and make sure that there is no object filled with liquid on the device to prevent liquid from flowing into it.
  • Operating temperature: –10 °C to +55 °C (+14 °F to +131 °F).
  • This is a class A product. In a domestic environment this may cause radio interference in which case you may be required to take adequate measures.
  • Do not block the ventilator of the device with objects, such as a newspaper, table cloth or curtain.
  • Do not place an open flame on the device, such as a lit candle.

Maintenance Requirements

tp link 48P Port Managed Switch- icon

Replacing unwanted batteries with the wrong type of new batteries might result in explosion.
Preventive measures (including but not limited to):

  • Replace unwanted batteries with new batteries of the same type and model to avoid the risk of fire and explosion.
  • Dispose of the old batteries as instructed.

tp link 48P Port Managed Switch- icon1

Power off the device before maintenance.

Overview

1.1 Introduction
This product is a 10-Gigabit uplink managed switch. Equipped with a high performance switching engine, the switch performs optimally. It has low transmission delay, large buffer and is highly reliable. The switch can work in environments ranging from –10 °C to +55 °C (+14 °F to +131 °F).
The protection for power input end from overcurrent, overvoltage and EMC can effectively resist the interference from static electricity, lightning, and pulse. In addition, through webpage management, SNMP (Simple Network Management Protocol), and other functions, the device can be remotely managed. Link aggregation and STP ensure its reliability.
The device is applicable for uses in different scenarios, including small and medium enterprises, chain business, branch agencies, government, schools and hotels.

1.2 Features

  • All gigabit ports, and the uplink ports is 10-Gigabit optical ports.
  • Supports STP and RSTP.
  • Supports VLAN configuration based on IEEE802.1Q.
  •  Supports static and dynamic link aggregation.
  • Supports graphical WEB management and easy operation.
  • EMC high protection design.
  • Desktop mount and rack mount.

Structure

2.1 Front panel

tp link 48P Port Managed Switch- Front panel

Table 2-1 Front panel description

No. Name Description
1 RJ-45 port 10/100/1000 Mbps self-adaptative Ethernet port.
2 SFP+ Port Supports 1/10 Gbps.
3 Console port Debugging serial port.
4 Reset button Press and hold the button for over 5 seconds, wait until all the indicators are solid on, and then release it. The device recovers to the default settings.
5 Power (PWR) indicator Displays the power status of the device in real time.
●  On: Power on.
●  Off: Power off.
6 System (SYS) indicator ●  Flashes: The system works normally.
●  Off: The system is not working normally.
7 Uplink SFP+ optical port status indicator ●  On: Connected to device.
●  Off: Not connected to device.
●  Flashes: Data transmission is in progress.
8 Port connection status indicator ●  Solid green: Connected to device, and the transmission rate is negotiated to 1000 Mbps.
●  Green flashes: Data transmission is in progress.
●  Solid yellow: Connected to device, and the transmission rate is negotiated to 10/100 Mbps.
●  Yellow flashes: Data transmission is in progress.
●  Off: Not connected to device.

2.2 Rear Panel

tp link 48P Port Managed Switch- Rear Panel

Table 2-2 Rear panel description

No. Name

Description

1 Grounding terminal Connects to the grounding wires.
2 Power port Supports 100–240 VAC.

Installation

3.1 Preparations

  • Select a proper installation method according to your actual needs.
  • Make sure that the working platform is stable and steady.
  • Leave about 10 cm space for heat dissipation to ensure good ventilation.

3.2 Desktop Mount
The device supports desktop mount. You can directly place it on a solid and flat desktop.
3.3 Rack Mount
Procedure
Step 1 Attach the mounting brackets to the switch (one on each side), and fix them with the provided screws.

tp link 48P Port Managed Switch- Rack Mount

Step 2 Fix the switch onto the rack.

tp link 48P Port Managed Switch- Rack Mount1

Wiring

4.1 Connecting GND Cable
There is a GND screw on the device cover board for the GND cable, which is called enclosure GND.
Connect one end of the GND cable with the cold-pressed terminal, and then fix it on the enclosure GND with the GND screw. The other end of the GND cable should be reliably connected to the ground.

  • Normal GND of the device is the important guarantee for device lightning protection and antiinterference. You should connect the GND cable before powering on the device, and then power off the device before disconnecting the GND cable.
  • Use a yellow-green protective grounding wire with the cross-sectional area of at least 4 mm² and the grounding resistance of no more than 4 Ω.

tp link 48P Port Managed Switch- Grounding terminal

4.2 Connecting SFP Ethernet Port
Prerequisites
We recommend wearing antistatic gloves before installing SFP module, and then wear antistatic wrist, and confirm the antistatic wrist is well linked to the surface of the gloves.
Procedure
Step 1 Lift the handle of SFP module upward vertically and make it get stuck to the top hook.
Step 2 Hold the SFP module on both sides and push it gently into the SFP slot till the SFP module is firmly connected to the slot (You can feel that both the top and bottom spring strip of the SFP module are firmly stuck with the SFP slot).

tp link 48P Port Managed Switch- icon1
The device uses laser to transmit signal via optical fiber cable. The laser conforms to the requirements of level 1 laser products. To avoid injury upon eyes, do not look at the 1000 Base-X optical port directly when the device is powered on.

  • tp link 48P Port Managed Switch- icon6 When installing the SFP optical module, do not touch the gold finger of the SFP optical module.
  • Do not remove the dust plug of the SFP optical module before connecting the optical port.
  • Do not directly insert the SFP optical module with the optical fiber inserted into the slot. Unplug the optical fiber before installing it.

tp link 48P Port Managed Switch- module structure

4.3 Connecting Ethernet Port
Ethernet port adopts standard RJ–45 port. Equipped with self-adaptation function, it can be automatically configured to full duplex/half-duplex operation mode, and supports MDI/MDI-X selfrecognition function of the cable, which means that the switch can use cross-over cable or straightthrough cable to connect terminal device to network device.

tp link 48P Port Managed Switch- Cable sequence1

The cable connection of RJ–45 connector conforms to the standard 568B (1-orange&white, 2orange, 3-green&white, 4-blue, 5-blue&white, 6-green, 7-brown&white, 8-brown).

tp link 48P Port Managed Switch- Pin description

4.4 Connecting Console Port
The switch console port and computer controlling 9-pin serial port are connected with RJ-45 DB9 cable. You can call the console software of the device by operating the superterminal software of the Windows system for device configuration, maintenance, and management.

tp link 48P Port Managed Switch- Console por

One end of RJ–45 DB9 cable is RJ–45 connector, which needs to be inserted into the console port of the device. And the other end is DB9 plug, which needs to be inserted into the computer controlling 9-pin serial port.

tp link 48P Port Managed Switch- Cable sequence

DB9 pin RJ–45 pin Signal Description
3 6 RXD Receiving data
2 3 TXD Transmitting data
5 4/5 GND GND

4.5 Connecting Power Cord
Background Information
Make sure that the switch is reliably grounded before connecting the power cord.
Procedure
Step 1 Connect one end of the power cord into the power jack of the device accurately.
Step 2 Connect the other end of the power cord to the external power socket.

Quick Operation

5.1 Logging in to the Webpage
You can log in to the webpage to perform operations on the device and manage it.
tp link 48P Port Managed Switch- icon6 For first-time login, follow the on-screen prompts to set your password.
Table 5-1 Default factory settings

Parameter Description
IP address 192.168.1.110/255.255.255.0
Username admin
Password You need to set the password for first-time login.

5.2 Restoring the Device to Its Factory Settings
There are 2 ways to restore the device to its factory settings.

  • Press and hold the Reset button for 5 seconds.
  • Log in to the webpage of the device and perform the required steps for factory reset. For information on these steps, see the user manual of the device.

Appendix 1 Security Recommendation

Account Management

  1. Use complex passwords
    Please refer to the following suggestions to set passwords:
    ● The length should not be less than 8 characters;
    ● Include at least two types of characters: upper and lower case letters, numbers and symbols;
    ● Do not contain the account name or the account name in reverse order;
    ● Do not use continuous characters, such as 123, abc, etc.;
    ● Do not use repeating characters, such as 111, aaa, etc.
  2.  Change passwords periodically
    It is recommended to periodically change the device password to reduce the risk of being guessed or cracked.
  3.  Allocate accounts and permissions appropriately Appropriately add users based on service and management requirements and assign minimum permission sets to users.
  4.  Enable account lockout function
    The account lockout function is enabled by default. You are advised to keep it enabled to protect account security. After multiple failed password attempts, the corresponding account and source IP address will be locked.
  5. Set and update password reset information in a timely manner
    The device supports password reset function. To reduce the risk of this function being used by threat actors, if there is any change in the information, please modify it in time. When setting security questions, it is recommended not to use easily guessed answers.

Service Configuration

  1. Enable HTTPS
    It is recommended that you enable HTTPS to access web services through secure channels.
  2.  Encrypted transmission of audio and video
    If your audio and video data contents are very important or sensitive, it is recommended to use encrypted transmission function in order to reduce the risk of your audio and video data being eavesdropped during transmission.
  3.  Turn off non-essential services and use safe mode
    If not needed, it is recommended to turn off some services such as SSH, SNMP, SMTP, UPnP, AP hotspot etc., to reduce the attack surfaces.
    If necessary, it is highly recommended to choose safe modes, including but not limited to the following services:
    ● SNMP: Choose SNMP v3, and set up strong encryption and authentication passwords.
    ● SMTP: Choose TLS to access mailbox server.
    ● FTP: Choose SFTP, and set up complex passwords.
    ● AP hotspot: Choose WPA2-PSK encryption mode, and set up complex passwords.
  4. Change HTTP and other default service ports
    It is recommended that you change the default port of HTTP and other services to any port between 1024 and 65535 to reduce the risk of being guessed by threat actors.

Network Configuration

  1. Enable Allowlist
    It is recommended that you turn on the allowlist function, and only allow IP in the allowlist to access the device. Therefore, please be sure to add your computer IP address and supporting device IP address to the allowlist.
  2.  MAC address binding
    It is recommended that you bind the IP address of the gateway to the MAC address on the device to reduce the risk of ARP spoofing.
  3. Build a secure network environment
    In order to better ensure the security of devices and reduce potential cyber risks, the following are recommended:
    ● Disable the port mapping function of the router to avoid direct access to the intranet devices from external network;
    ● According to the actual network needs, partition the network: if there is no communication demand between the two subnets, it is recommended to use VLAN, gateway and other methods to partition the network to achieve network isolation;
    ● Stablish 802.1x access authentication system to reduce the risk of illegal terminal access to the private network.

Security Auditing

  1. Check online users
    It is recommended to check online users regularly to identify illegal users.
  2.  Check device log
    By viewing logs, you can learn about the IP addresses that attempt to log in to the device and key operations of the logged users.
  3.  Configure network log
    Due to the limited storage capacity of devices, the stored log is limited. If you need to save the log for a long time, it is recommended to enable the network log function to ensure that the critical logs are synchronized to the network log server for tracing.

Software Security

  1. Update firmware in time
    According to the industry standard operating specifications, the firmware of devices needs to be updated to the latest version in time in order to ensure that the device has the latest functions and security. If the device is connected to the public network, it is recommended to enable the online upgrade automatic detection function, so as to obtain the firmware update information released by the manufacturer in a timely manner.
  2. Update client software in time
    It is recommended to download and use the latest client software.

Physical Protection
It is recommended that you carry out physical protection for devices (especially storage devices), such as placing the device in a dedicated machine room and cabinet, and having access control and key management in place to prevent unauthorized personnel from damaging hardware and other peripheral equipment (e.g. USB flash disk, serial port).

tp link- logo

Documents / Resources

tp-link 48P Port Managed Switch [pdf] User Guide
48P Port Managed Switch, Port Managed Switch, Managed Switch

References

Leave a comment

Your email address will not be published. Required fields are marked *