Totalcomp SW Series Scales and Components Instruction Manual
Totalcomp SW Series Scales and Components

PRECAUTIONS

Precautions when installing the scale. To ensure that you get the most from your scale, please follow these instruction.

Warning Icon Warning

Do not disassemble the scale. When any damage or defect occurs, contact your CAS authorized dealer immediately for proper repair.
Safety Instruction
Do not overload beyond the maximum weight limit.
Safety Instruction
Scale must be grounded to minimize electricity static. This will minimize defect or electric shock.
Safety Instruction
Do not pull the plug by its cord when unplugging. Damaged cord could cause electric shock or fire.
Safety Instruction
To prevent from fire occurring, Do not place or use the scale near flammable or corrosive gas.
Safety Instruction
To reduce electric shock or incorrect reading, Do not spill water on the scale or place it in humid condition.
Safety Instruction
Avoid placing the scale near heater or in direct sunlight
Safety Instruction
Insert plug firmly to wall outlet to prevent electric shock
Safety Instruction
Use proper Adapter. Incorrect adapter could damage the scale.
Safety Instruction

Make sure to plug your scale into the proper power outlet. For maximum performance, plug into a power outlet 30 minutes before the usage for warm up.

Warning Icon Attention

For consistent and accurate reading, maintain periodical check by your CAS authorized dealer
Safety Instruction
Avoid sudden shock to the scale. Internal mechanism could be damaged.
Safety Instruction
Grab on the bottom of the scale when moving. Do not hold by the platter.
Safety Instruction
Take the battery out when scale is not in use for long time. Leakage from the batteries is hazardous.
Safety Instruction
Place the scale on firm and temperature consistent environment.
Safety Instruction
By adjusting 4 corners of the scale, set the scale even using the built in scale leveling indicator
Safety Instruction
Keep the scale away from other electromagnetic generating devices. This may interfere with accurate reading.
Safety Instruction

PREFACE

  • Thank you for purchasing our CAS SW Series.
  • This scale has been designed with CAS reliability, under rigid quality control and with outstanding performance. Your specialty departments can enjoy these high quality reliable CAS products.
  • We believe that your needs will be satisfied and you will have excellent reliability.
  • This manual will help you with proper operation and care of the SW Series.
  • Please keep it handy for future reference.

NAMES AND FUNCTIONS

OVERALL VIEW
Function

DISPLAY & KEYBOARD

Display

FUNCTION

Keys Used to set the zero point
Keys Used to enter a tare weight and used to cancel a tare weight.
Keys Used to convert the unit of weight.
Keys Turn on and off the display

OPERATIONS

  • Turn on the display by pressing ON/OFF key.
  • Then the display will show all the segments and count up “0” to “9”. (If you want to stop it, press the ZERO key.)
  • When you turn on the display, make sure that platter is empty. Otherwise, display will show the “Err 1”. (Refer to ERROR MESSAGE)
  • The display indicates if the scale is at ZERO or if there is a TARE Entered into the scale by way of a ZERO and NET lamps.
  • When the weight of commodity is stable, display will show the (STABLE) lamp.
  • When the display is not zero though there is nothing on the platter, press the ZERO key

General Weighing

  1. Place a commodity on the platter.
    General Weighing
  2. Remove the commodity from the platter.
    General Weighing

Weighing with Tare

  • Tare is the weight of container being used for a commodity.
  • The TARE key subtracts the weight of the container.
  1. Place a container on the platter.
    General Weighing
  2. Press the TARE key.
    General Weighing
  3. Place a commodity in the container, then the display will show only the weight of the commodity.
    General Weighing

 

  1. Remove the container and commodity, then the display will show the weight of the container with “-” sign.
    General Weighing
  2. Press the TARE key, then display will show the “0.000”.
    General Weighing

How to Convert the Unit of Weight

  • Press the UNIT key, then the display will show the “UnIt” for a second.
  • Press the UNIT key until the display shows the unit that you wish to take.
  • NOTE: Unit of measure is g, kg, lb, and oz selectable by pressing UNIT key.

How to Set Auto Power Off

Auto-Power off makes the battery’s life longer.
When you don’t operate the scale, this function makes the power OFF automatically.

Before setting the Auto Power Off, make sure that the power is OFF

  1. While you press the ZERO key, press the ON/OFF key, then you will see the AP-10. (If you have set this before, display will show previous value.)
    General Weighing
  2. Press the TARE key, until the display shows the “AP-x0” that you wish to take. (Refer to TABLE 1.)
    General Weighing
  3. Press the ZERO key, then the scale saves what you programmed and shows all the segments and count up “0” to “9”.
    General Weighing

TABLE 1. 

DISPLAY FUNCTION
AP-00 This function will keep scale on continuously.
AP-10 If you don’t operate the scale for 10 minutes, this function will turn the power OFF.
AP-20 If you don’t operate the scale for 20 minutes, this function will turn the power OFF
AP-30 If you don’t operate the scale for 30 minutes, this function will turn the power OFF.

BATTERY SYSTEM

LOW BATTERY
When the battery is low, display will show the “BAT” indication. A new battery is required. Battery compartment is located on the bottom of the scale.

If you use the scale without replacing the battery, display will show “LObAt” and then scale will shut OFF.

ERROR MESSAGE

ERROR REASONS SOLUTIONS
Err 1 An error of the initial zero range Set the platter empty
O-L An overload Refer to specifications

SPECIFICATIONS

ODEL SW-2 • SW-5                          SW-10  SW-20
CAPACITY 5 x0.0021b2 x 0.001 kg80 x 0.05 oz 10 x 0.005 lb5 x 0.002 kg160 x0.1oz 20 x 0.01 lb10 x 0.005 kg400 x 0.2 oz 50 x0.02Ib20 x 0.01 kg800 x0.5oz
DISPLAY LCD (5 DIGIT)
TEMPERATURE RANGE -10°C — +40°C (14°F —104°F)
POWER SUPPLY 1.5V x6 (D size Battery)
POWER CONSUMPTION APPROX. 0.25W
BATTERY OPERATINGTIME 500 hours (Manganese battery),1000 hours (Alkaline battery)
PLATTER SIZE (inch/mm) 9.1(W) x 7.5(D) / 230(W) x 190(D)
PRODUCT SIZE (inch/mm) 10.2(W) x 11.3(D) x 5.4(H) / 260(W) x 287(D) x 137(H)
PRODUCT WEIGHT 6.2 lb / 2.8 kg
OPTION 9V Adapter 300mA, Rear display

Notice: Specifications are subject to change for improvement without notice.

CALIBRATION MODE WEIGHT SETTINGS FOR SW1N OR Z SERIES
  1. Make sure the scale is off. Remove the platter assembly (metal and/or plastic platform.)
  2. On the right hand side you will find a hole and a screw at the bottom. This is the sealing screw. Remove the sealing screw and then turn the scale upside down to find the calibration screw and silver plate located on the right side of the bottom of the scale (if keyboard is facing you and you tilt the scale upwards by the front.)
  3. Remove the calibration screw and the silver plate. Under the plate is the calibration switch.
  4. Press and hold the switch while turning the scale on. The display will show “ONE” and then “CAL 1”. Release the calibration switch.
  5. The “TARE” key advances through the cal settings whereas the “UNIT” goes down. The “ZERO” key enters the cal setting.
  6. Press the “UNIT” key twice to go to “CAL 10”. Press the “ZERO” key to enter into the settings.
  7. The display will flash “UNIt” and then a number. 0 is for calibrating in KG and 1 is for calibrating in LBS. Select the unit by using the “UNIT” key. that is being used for calibration and press the “ZERO” key.
  8. When putting in the values you must adhere to the capacity and increment on the serial number plate and match the correct values according to that or else the scale will not be NTEP or “legal for trade” subject to being RED TAGGED and a fine by Weights And Measures.
  9. The display will flash “CAPA” and then show the current capacity. The chart below shows the capacities to be set. Only use the capacity setting that is shown on the front of the scale. The “UNIT” key will increment the flashing digit while the “TARE” key selects the digit that will flash. If 1 was selected for the unit follow the settings listed under 1. If 0 was selected for the unit follow the settings under 0. You cannot make the scale different then what is on the spec plate or else the scale will not be NTEP and subject to a fine and being red tagged by Weights and Measures.
    Display Shows Display Shows
    Calibration Unit 1 is lb 0 is kg
    Capacity Capacity
    5LBS 00005 2KG 00002
    10LBS 00010 5KG 00005
    20LBS 00020 10KG 00010
    50LBS 00050 20KG 00020
    Weight used This is part Weight
    in      Cal      3 of a three used in Cal
    ld during point 3 during
    calibration. calibration calibration.
    This    cannot during    cal This cannot
    be set to 0. 3 be set to 0.
    W-dP W-dP
    5LBS 3 2KG 3
    10LBS 3 5KG 3
    20LBS 2 10KG 3
    50LBS 2 20KG 2
    ld ld
    5LBS 0.002 2KG 0.001
    10LBS 0.005 5KG 0.002
    20LBS 0.01 10KG 0.005
    50LBS 0.02 20KG
  10. After the capacity is set press the “ZERO” key. The display will flash “ ld” and show the middle up/down weight to be used in calibrating the scale. This can not be set to 0. Later versions a value of 0 can be entered. The value must be between 10% and 90% of the full capacity.
  11. Press the “ZERO” key and the display will flash “u-dP” and display the weight decimal point. Use the W-dP from the above chart for the capacity of the scale. Press the “ZERO” key.
  12. The display will flash “ld” and then show the increment. Use the ld from the above chart for the capacity of the scale. Press the “ZERO” key.
  13. he display will flash “dUAL” and then show a number. 0 disables dual range while 1 enables dual range. Select 0 or 1using the unit key. Press the “ZERO” key.
  14. The scale will flash “tArE” and display a number. The “UNIT” key changes the number. Only 0 or 1 is allowed. 0 allows for full scale tare. Selecting “1” and then pressing the “ZERO” key allows limiting the tare from 0 to full scale. The display will show 5 digits. As an example on a 50LB scale if it is made to be 05000 the scale will only tare up to 4.99.
  15. Press the “ZERO” key and the display will go back to “CAL 10”.
  16. If all the calibration settings are done turn the scale off and then on. The display will show the version number, count up, and go to the weigh mode.
SPAN CALIBRATION FOR SW1N-SERIES FULL CAPACITY CALIBRATION
  1. Make sure the scale is off. Remove the platter assembly (metal and/or plastic platform.)
  2. On the right hand side you will find a hole and a screw at the bottom. This is the sealing screw. Remove the sealing screw and then turn the scale upside down to find the calibration screw and silver plate located on the right side of the bottom of the scale (if keyboard is facing you and you tilt the scale upwards by the front.)
  3. Remove the calibration screw and the silver plate. Under the plate is the calibration switch.
  4. Press and hold the switch while turning the scale on. The display will show “ONE” and then “CAL 1” then release the calibration switch.
  5.  The “TARE” key advances through the cal settings whereas the “UNIT” goes down. The “ZERO” key enters the cal setting. If a per cent calibration is to be performed proceed to per cent calibration.
  6. Before doing the calibration the middle up/down value has to be known. To do this go to “CAL
  7. by pressing the “UNIT” key twice. Press the “ZERO” key to enter into the setting. First is “UNIT” then a number. The number represents the unit of calibration. 1 is for LBS and 0 is for KG.
  8. Press the “ZERO” key and the display will show “CAPA” and then the scales capacity. Press the “ZERO” key and the display will show “ ld”. This is the middle up/down weight to be used in the  calibration. This value CANNOT be set to 0. It must be between 10-90% expressed as weight not a percentage. Input a value to use by using the “TARE” and “UNIT” keys. Make note of this value and keep pressing the “ZERO” key to get back to “CAL 10”.
  9. Press the “UNIT” key until the display shows “CAL 3”. Press the “ZERO” key to enter into calibration.
  10. The display will show “2ErO”. With the platter on the scale and nothing on the platter press the  “ZERO” key. The display will show raw internal counts and then display “ ldUP”. Place the weight on the platter that was noted in step 7.
  11. Press the “ZERO” key. The display will show internal counts and then “FULL”. Either remove the weight and/or add weights so that the full capacity weight of the scale is on the platter and press the “ZERO” key.
  12. The display will show internal counts and then display “ lddn”. Put the same weight used in step 9 on the platter. Press the “ZERO” key. The display will show internal counts and the go back to “CAL 3”. Remove the weight from the platter.
  13. Turn the scale off and then back on. The scale will display the version, count up, and go into the weigh mode.

PER CENT CALIBRATION 

  1. Press the “TARE” key until the display shows “CAL 7”. Press the “ZERO” key to enter into per cent calibration.
  2. The display will show “Per 10”. The “UNIT” key will increment the flashing digit and the “TARE” key will select which digit is flashing. When the per cent is set press the “ZERO” key.
  3. The display will show “2ErO”. With the platter on the scale and nothing on the platter press the “ZERO” key. The display will show internal counts and then display “P5Pan”.
  4. Put the per cent of weight on the platter that was specified in step 2. Press the “ZERO” key. The display will show internal counts and then go back to “CAL 7”. Remove the weight from the platter. Turn the scale off and back on. The scale will display the version, count up, and go into the weigh mode.