Tigo TS4-A-O Module Level PV Optimizer Instruction Manual

Product Information

The TS4-A-O (Optimization) is the advanced add-on optimization solution that brings smart module
functionality to standard PV modules for higher reliability. Improve energy efficiency by upgrading underperforming PV systems or adding smart features to new installations.
The TS4-A-O complies with NEC 2017 and 2020 690.12 Rapid Shutdown specifications when installed on each module and accompanied by the Tigo Access Point (TAP) and the Cloud Connect Advanced (CCA). Module-level DC production data, as well as data from other Modbus connected devices, can be analyzed via Tigo’s Energy Intelligence Software when connected to the cloud.
The TS4-A-O with UHD-Core technology and expanded specifications supports PV modules up to 700W, and 15A.

Included Features


Module-level optimization for increased energy yield and greater design flexibility

Manual or automatic module-level shutdown. Complies with NEC 2017 and 2020.

Module-level monitoring for energy production tracking and system management

Easy Installation

Snap to standard module frame or remove clips for rack mounting

Smart Commissioning

Configure and commission with your Android or iOS mobile device

TS4-A-O SPECIFICATIONS

Environmental

Operating Temperature Range 40°C to +70°C (-40°F to +158°F)
Outdoor Rating IP68, NEMA 3R
Maximum Elevation 2000m
Mechanical
Dimensions W=138.4mm, L= 139.7mm, H= 22.9mm
Weight 520g
Electrical
Max Input Voltage (VOC @ Lowest Temperature) 80V
Input Voltage Range 16 – 80V*
Maximum Cont. Current (Imax 15A
Maximum Short Circuit Current (Isc) 20A
Maximum Power 700W
Cable Length (in/out) 0.12/1.2m (standard), 0.62/1.2m (optional)
Connectors MC4 (standard), EVO2 (optional)
Communication Type Wireless
Recommended Fuse Rating 30A
Rapid Shutdown Time Limit 30 secs or less**
PVRSE Controlled Conductors ≤30 Vdc, ≤240VA, ≤8A**

TAP required for module-level shutdown and CCA required for monitoring with TS4-A-O.
*VMOD MAX of the connected panel = TS4-A-O VDCU MAX
**Limits are based on NEC 690.12 rapid shutdown requirements.

*Clips can be removed for rack mounting


Module frame specifications for mounting TS4-A

ORDERING INFORMATION

Standard Description
461-00252-32 15A, 700W, 1500VUL/1000V IEC, 1.2M Cable, MC4
Options Description
461-00252-62 15A, 700W, 1500VUL/1000V IEC, 0.62/1.2M Cable, MC4
461-00261-62 15A, 700W, 1500VUL/IEC, 0.62/1.2M Cable, EVO2
461-00261-32 15A, 700W, 1500VUL/IEC, 1.2M Cable, EVO2

EN 62109-1

www.tuv.com
ID 0007000000

For sales info:
sales@tigoenergy.com

For product info:
Visit : tigoenergy.com/products

For technical info:
Visit : support.tigoenergy.com

For additional info and product selection assistance, use Tigo’s online design tool at tigoenergy.com/design
Downloads

Tigo Energy, Inc. | www.tigoenergy.com | sales@tigoenergy.com

Documents / Resources

Tigo TS4-A-O Module Level PV Optimizer [pdf] Instruction Manual
TS4-A-O Module Level PV Optimizer, TS4-A-O, Module Level PV Optimizer, Level PV Optimizer, PV Optimizer

References

Leave a comment

Your email address will not be published. Required fields are marked *