1. สินค้าหมดview
The Generac RTSW200G3 is a 200 Amp Service Rated Three-Phase Automatic Transfer Switch designed for use with Generac generators equipped with Evolution or Nexus Controllers. This unit facilitates the automatic transfer of electrical load between utility power and a standby generator, ensuring continuous power supply during outagใช่
คุณสมบัติที่สำคัญ ได้แก่:
- Durable and Weather-Resistant Enclosure: Features an aluminum NEMA/UL Type 3R enclosure with electrostatically applied powder coating for long-lasting performance in various weather conditions.
- Robust and UL Recognized Contactors: Heavy-duty Generac contactors are recognized by UL for reliability and designed for extended service life.
- Efficient and Intelligent Control: The integrated controller at the generator manages all timing, sensing, exercising functions, and transfer commands for seamless operation.
- Single-Person Installation Design: Engineered to streamline the setup process.

Image showing the Generac RTSW200G3 200 Amp Service Rated 120/208 3Ø Power Transfer Switch, highlighting its robust aluminum enclosure.
2. ข้อมูลด้านความปลอดภัย
คำเตือน: Installation and service of this transfer switch must be performed by a qualified, licensed electrician in accordance with all applicable electrical codes and standards. Failure to do so can result in serious injury, death, or property damage.
- Always disconnect all power sources before servicing the transfer switch.
- ตรวจสอบให้แน่ใจว่าได้ต่อสายดินและเชื่อมต่ออย่างถูกต้องตามข้อกำหนดด้านไฟฟ้าของท้องถิ่น
- Do not operate the transfer switch if any part is damaged or appears to be malfunctioning.
- ผลิตภัณฑ์นี้ประกอบด้วยสารเคมีที่รัฐแคลิฟอร์เนียทราบว่าก่อให้เกิดมะเร็งและความพิการแต่กำเนิดหรืออันตรายต่อระบบสืบพันธุ์อื่นๆ (คำเตือนตามข้อเสนอ 65)
3. การตั้งค่าและการติดตั้ง
The Generac RTSW200G3 is designed for a single-person installation, however, Generac strongly recommends that installation be performed by a certified and licensed electrician. This ensures compliance with all electrical codes and safety standards.
- The transfer switch is listed to UL 1008 for Optical Standby applications.
- Service Disconnects are listed to UL 489.
- The enclosure is provided with an integrated deadfront for safe operation of the Service Disconnect.
- Refer to the detailed wiring diagrams and installation instructions provided with the physical product for specific connection procedures.
4. คู่มือการใช้งาน
The Generac RTSW200G3 operates automatically in conjunction with your Generac generator's Evolution or Nexus Controller. The transfer switch monitors the utility power supply.
- ไฟฟ้าดับ: Upon detection of a utility power outage, the generator controller will initiate the generator startup sequence. Once the generator reaches proper operating parameters, the transfer switch will automatically transfer the electrical load from the utility to the generator.
- การฟื้นฟูระบบไฟฟ้า: When utility power is restored and stable, the transfer switch will automatically transfer the electrical load back to the utility. The generator will then enter a cool-down period before shutting down.
- การดำเนินการด้วยตนเอง: Consult your generator's controller manual for any manual override or testing procedures.
5. การบำรุงรักษา
Regular maintenance ensures the longevity and reliable operation of your transfer switch. Always disconnect all power sources before performing any maintenance.
- การตรวจสอบประจำปี: Have a qualified electrician inspect the transfer switch annually. This includes checking for loose connections, signs of corrosion, and proper operation of moving parts.
- รักษาความสะอาด: Ensure the enclosure is free from dust, debris, and moisture.
- ทดสอบเป็นประจำ: Follow the recommended testing schedule for your generator and transfer switch system to ensure it functions correctly during an actual power outage.
6 การแก้ไขปัญหา
If you experience issues with your Generac RTSW200G3 transfer switch, consider the following basic troubleshooting steps. For complex issues, contact a qualified electrician or Generac customer support.
- ไม่รับการโอนกรรมสิทธิ์: Verify that the generator is running and producing power. Check the generator controller for any fault codes. Ensure all circuit breakers are in the ON position.
- การทำงานเป็นระยะ: Check all wiring connections for tightness and signs of damage. Ensure the utility power supply is stable.
- เสียงที่ผิดปกติ: Immediately shut down the system and contact a qualified technician.
7. ข้อมูลจำเพาะ
| ข้อมูลจำเพาะ | รายละเอียด |
|---|---|
| ยี่ห้อ | เจเนอแรค |
| ชื่อรุ่น | RTSW200G3 |
| คะแนนปัจจุบัน | 200 Amps |
| เล่มที่tage | 120/208V (3Ø) |
| วัดtagอี (สูงสุด) | 41600 วัตต์ |
| เริ่มต้นวัดtagอี (สูงสุด) | 104000 วัตต์ |
| วัสดุ | อลูมิเนียม |
| ประเภทตู้ปิด | NEMA/UL Type 3R |
| ขนาดสินค้า | 27.2 x 26 x 26.5 นิ้ว |
| น้ำหนักสินค้า | 30 ปอนด์ |
| ASIN | B01LXG7NT4 |
| ยูพีซี | 696471620467 |
8. การรับประกันและการสนับสนุน
The Generac RTSW200G3 comes with a การรับประกันแบบจำกัดห้าปี, providing confidence in your power transfer solution.
For technical assistance, warranty claims, or to locate authorized service providers, please contact Generac customer support or visit the official Generac webเว็บไซต์. คุณยังสามารถเยี่ยมชม ร้าน Generac บน Amazon สำหรับข้อมูลผลิตภัณฑ์เพิ่มเติม