1. สินค้าหมดview
The SIMPLEX 742-346 - 4009A NAC Extender Board is a critical component designed to expand the Notification Appliance Circuit (NAC) capabilities of compatible fire alarm control panels. This board facilitates the connection of additional audible and visual notification devices, such as horns, strobes, and speakers, ensuring comprehensive coverage and compliance with fire safety regulations. It is engineered for reliable performance within fire detection and alarm systems.

รูปที่ 1 : ด้านหน้า view of the SIMPLEX 4009A NAC Extender Board, showing various electronic components, terminals, and connectors. This board is essential for expanding fire alarm system notification capabilities.
2. การตั้งค่าและการติดตั้ง
Proper installation of the NAC Extender Board is crucial for its correct operation and the overall integrity of the fire alarm system. Installation should only be performed by qualified personnel in accordance with all local and national electrical codes, as well as the manufacturer's instructions.
2.1. รายการตรวจสอบก่อนการติดตั้ง
- Verify that the fire alarm control panel is powered off and isolated from all power sources.
- ตรวจสอบให้แน่ใจว่ามีเครื่องมือและอุปกรณ์ติดตั้งที่จำเป็นครบถ้วน
- Confirm compatibility of the 742-346 board with your existing fire alarm control panel.
- Review the system wiring diagrams.
2.2. Mounting the Board
- Select a suitable location within the fire alarm control panel enclosure or a dedicated auxiliary enclosure, ensuring adequate ventilation and clearance.
- Secure the NAC Extender Board using appropriate standoffs and screws to prevent short circuits and ensure stability.
2.3. การเชื่อมต่อสายไฟ
All wiring must comply with NFPA 70 (National Electrical Code) and NFPA 72 (National Fire Alarm and Signaling Code) requirements.
- การเชื่อมต่อไฟฟ้า: Connect the board to the designated power source from the fire alarm control panel. This board operates on a corded electric power source.
- Data/Communication Link: Connect the communication bus from the main fire alarm control panel to the extender board's input terminals.
- NAC Outputs: Connect the notification appliances (horns, strobes, etc.) to the designated NAC output terminals on the extender board. Ensure correct polarity and supervision wiring.
- การต่อลงดิน: Ensure proper grounding of the board and enclosure to prevent electrical hazards and interference.
2.4 การตรวจสอบหลังการติดตั้ง
- Visually inspect all connections for proper termination and security.
- Verify that no loose wires or debris are present within the enclosure.
- Once verified, restore power to the fire alarm control panel and observe the system for proper operation and any fault indicators.
3. การดำเนินการ
The SIMPLEX 4009A NAC Extender Board operates as an integral part of the fire alarm system. Once properly installed and configured, it automatically extends the capacity of the main fire alarm control panel's Notification Appliance Circuits. When an alarm condition is detected by the main panel, the extender board receives the signal and activates the connected notification appliances, such as audible alarms and visual strobes, to alert occupants.
The board is designed for continuous, supervised operation, meaning it constantly monitors the integrity of its connected circuits. Any open circuits, short circuits, or ground faults on the NACs connected to the extender board will be reported back to the main fire alarm control panel as a trouble condition, allowing for prompt identification and resolution of issues.
4. การบำรุงรักษา
Regular maintenance ensures the longevity and reliable operation of the NAC Extender Board and the entire fire alarm system. Maintenance should be performed by qualified technicians.
4.1. การตรวจสอบตามปกติ
- ตรวจสอบด้วยสายตา: Periodically inspect the board for any signs of physical damage, corrosion, or overheating (discoloration).
- ความสมบูรณ์ของการเชื่อมต่อ: Verify that all wiring connections are secure and free from loose strands or signs of wear.
- สภาพแวดล้อม : Ensure the operating environment remains within specified temperature and humidity ranges, free from excessive dust or moisture.
4.2. การทำความสะอาด
- If necessary, gently clean the board using a soft, dry, lint-free cloth.
- For stubborn dust, use compressed air, ensuring it is free of moisture and contaminants.
- ห้ามใช้น้ำยาทำความสะอาดหรือตัวทำละลายชนิดเหลวโดยตรงกับแผงวงจร
5 การแก้ไขปัญหา
This section provides guidance for common issues. For complex problems, contact qualified fire alarm technicians or SIMPLEX technical support.
| ปัญหา | สาเหตุที่เป็นไปได้ | สารละลาย |
|---|---|---|
| NACs not activating | No power to board; Communication link issue; Faulty NAC wiring; Defective notification appliance. | Check power supply; Verify communication wiring; Inspect NAC wiring for opens/shorts; Test individual appliances. |
| Trouble/Fault indication on main panel | Open circuit on NAC; Short circuit on NAC; Ground fault; Board malfunction. | Isolate and test each NAC circuit; Check for accidental grounds; Consult main panel's manual for specific trouble codes. |
| Board appears dead (no indicators) | No input power; Incorrect wiring. | ตรวจสอบการเชื่อมต่อแหล่งจ่ายไฟและระดับเสียงtage; Recheck all power and communication wiring. |
6. ข้อมูลจำเพาะ
| คุณลักษณะ | รายละเอียด |
|---|---|
| ผู้ผลิต | ซิมเพล็กซ์ |
| หมายเลขชิ้นส่วน | S742-346 |
| แบบอย่าง | 4009A NAC Extender Board |
| น้ำหนักสินค้า | 2 ปอนด์ |
| แหล่งพลังงาน | สายไฟ |
| รายการ จำนวนแพ็คเกจ | 1 |
| จำเป็นต้องใช้แบตเตอรี่หรือไม่? | เลขที่ |
| ประเภทสัญญาณเตือน | Audible (for connected devices) |
| ASIN | B01F4EW8YW |
7. การรับประกันและการสนับสนุน
For specific warranty information regarding the SIMPLEX 742-346 - 4009A NAC Extender Board, please refer to the documentation provided with your purchase or contact SIMPLEX directly. Warranty terms typically cover defects in materials and workmanship under normal use.
For technical support, installation assistance, or troubleshooting beyond the scope of this manual, it is recommended to contact a certified fire alarm technician or SIMPLEX customer service. Ensure you have your product model number (S742-346) and serial number ready when seeking support.
You can find more information about SIMPLEX products and support on their official webเว็บไซต์หรือผ่านตัวแทนจำหน่ายที่ได้รับอนุญาต