1. บทนำ
The Altronix ACM8 Access Power Controller is designed to manage power distribution for access control systems. This unit features eight individually fused trigger outputs, providing reliable power and protection for various access control devices. It is suitable for a range of applications requiring controlled power distribution.
2. สินค้าหมดview
The ACM8 is a versatile power distribution board, ideal for integrating with access control panels. It provides individually fused outputs, ensuring protection for connected devices. The board is constructed from durable phenolic or fiberglass material and is UL Recognized, meeting UL294 standards for access control system units.

รูปที่ 1: จากบนลงล่าง view of the Altronix ACM8 Access Power Controller board, showing the eight fused outputs, relays, and terminal blocks.

รูปที่ 2: มุม view of the Altronix ACM8 Access Power Controller, highlighting the compact design and component layout.
3. คุณสมบัติ
- Eight individually fused outputs for device protection.
- อินพุต Voltage: 12 to 24 Volt AC or DC.
- ปริมาณการส่งออกtage: 12 to 24 Volt AC or DC.
- UL Recognized and UL294 compliant for access control applications.
- Constructed from durable Phenolic or Fiberglass material.
- ขนาดกะทัดรัดเพื่อการบูรณาการที่ง่ายดาย
4. ข้อมูลจำเพาะ
| ข้อมูลจำเพาะ | รายละเอียด |
|---|---|
| หมายเลขรุ่น | ACM8 |
| ขนาดสินค้า (กว้าง x ยาว x สูง) | 8 x 4.5 x 1.25 นิ้ว |
| อินพุต Voltage | 12 to 24 Volt AC or DC |
| ปริมาณการส่งออกtage | 12 to 24 Volt AC or DC |
| จำนวนผลผลิต | 8 (Fused) |
| วัสดุ | Phenolic or Fiberglass |
| มาตรฐาน | UL RECOGNIZED, UL294 |
| น้ำหนักสินค้า | 11.2 ออนซ์ |
| ผู้ผลิต | อัลทรอนิกส์ |
5. การตั้งค่า
- การติดตั้งหน่วย: Securely mount the ACM8 board in a suitable enclosure or panel using appropriate hardware. Ensure adequate ventilation if enclosed.
- การเชื่อมต่อไฟฟ้า: Connect the main power source (12-24V AC or DC) to the designated input terminals. Observe correct polarity when using a DC input. Refer to the board markings for positive (+) and negative (-) terminals.
- การเชื่อมต่อขาออก: Connect your access control devices (e.g., locks, readers) to the individually fused output terminals. Each output provides power when triggered. Ensure proper wiring for each connected device according to its specifications.
- อินพุตทริกเกอร์: Connect the trigger input from your access control panel or other control device to the ACM8's trigger terminals. This signal will activate the corresponding output.
- การต่อลงดิน: Ensure the unit is properly grounded according to local electrical codes and safety standards.
6. คู่มือการใช้งาน
- เพิ่มพลัง: Once all connections are secure and verified, apply power to the ACM8 unit.
- ไฟ LED แสดงสถานะ: Each output has an associated LED indicator. When an output is active and power is flowing correctly through its fuse, the corresponding LED will illuminate.
- ฟังก์ชันทริกเกอร์: When a trigger signal is received at the input, the ACM8 will activate the designated output, providing power to the connected access control device.
- Fuse Monitoring: The LED indicators also serve as a visual check for fuse integrity. If an LED is off when the output should be active, it indicates a potential blown fuse or a wiring issue to the connected device.
7. การบำรุงรักษา
- การตรวจสอบปกติ: ตรวจสอบการเชื่อมต่อสายไฟทั้งหมดเป็นระยะ เพื่อให้แน่ใจว่าแน่นหนาและปราศจากสนิมหรือความเสียหาย
- การเปลี่ยนฟิวส์: If an output fuse blows, always replace it with a fuse of the same type and rating (e.g., 250V, 2A). Using an incorrect fuse can damage the unit or connected devices.
- การทำความสะอาด: รักษาเครื่องให้ปราศจากฝุ่นและสิ่งสกปรก ใช้ผ้าแห้งนุ่มในการทำความสะอาด ห้ามใช้น้ำยาทำความสะอาดหรือตัวทำละลาย
- สภาพแวดล้อม : Ensure the operating environment remains within specified temperature and humidity ranges to prevent malfunction.
8 การแก้ไขปัญหา
- No Power to Any Outputs:
- Verify that the main input power supply is active and correctly connected to the ACM8.
- Check the main fuse (if applicable to your power supply) and ensure it is intact.
- Individual Output Failure (LED off when active):
- Check the specific output fuse for the affected channel. Replace if blown.
- Verify the wiring to the connected device for shorts or disconnections.
- Ensure the trigger signal for that specific output is being received correctly.
- การทำงานเป็นระยะ:
- Inspect all terminal connections for looseness.
- ตรวจสอบปริมาตรtage fluctuations from the input power supply.
9. การรับประกันและการสนับสนุน