1. Муқаддима
This manual provides detailed instructions for the safe and effective use of your Sealey MM20HV Digital Multimeter. The MM20HV is a heavy-duty, general-purpose multimeter designed for various electrical measurements, featuring a clear LCD display, data hold function, temperature probe, and diode test facility. It is housed in a rugged rubber boot with an integral stand for durability and convenience.
Лутфан пеш аз истифода бурдани дастгоҳ ин дастурро бодиққат хонед ва онро барои истинод дар оянда нигоҳ доред.
2. Маълумот оид ба бехатарӣ
Always observe basic safety precautions when using electrical testing equipment to reduce the risk of fire, electric shock, and personal injury.
- Дастурҳоро хонед: Пеш аз истифода ҳама дастурҳои истифода ва огоҳиҳои бехатариро фаҳмед.
- Тафтиши дастгоҳ: Before each use, inspect the multimeter and test leads for any damage. Do not use if damaged.
- Proper Range: Always select the correct function and range for the measurement.
- Ҷилдиtage Маҳдудиятҳо: Do not exceed the maximum input limits specified for each range.
- Давраҳои зинда: Never measure resistance, continuity, or diode on a live circuit. Ensure power is off and circuits are discharged.
- Изолятсия: Keep fingers behind the probe barriers during measurements.
- Муҳити зист: Do not use the multimeter in wet conditions or in the presence of explosive gases or fumes.
- Хизматрасонӣ: Refer all servicing to qualified personnel. Battery and fuse replacement are the only user-serviceable parts.
3. Дар қуттӣ чӣ мавҷуд аст
Ҳангоми кушодан, боварӣ ҳосил кунед, ки ҳамаи ҷузъҳои дар поён овардашуда мавҷуд ва осеб надидаанд:
- Sealey MM20HV Digital Multimeter
- Рақамҳои санҷишӣ (сурх ва сиёҳ)
- Термопар (санҷи ҳарорат)
- Дастури корбар (ин ҳуҷҷат)

Расми 1: Sealey MM20HV Digital Multimeter shown with included test leads and thermocouple.
4. Танзимот
4.1. Насби батарея
The Sealey MM20HV requires two AAA batteries for operation.
- Сарпӯши қисмати батареяро дар қафои мултиметр ҷойгир кунед.
- Use a screwdriver to remove the screw securing the cover.
- Ду батареяи AAA-ро ҷойгир кунед ва қутби дурустро (+ ва -), чунон ки дар дохили қутб нишон дода шудааст, риоя кунед.
- Сарпӯши қисмати батареяро иваз кунед ва онро бо винт маҳкам кунед.
4.2. Пайваст кардани рахҳои санҷишӣ
Proper connection of test leads is essential for accurate and safe measurements.
- Insert the black test lead into the "COM" (Common) jack.
- Барои аксари ҳаҷмҳоtage, resistance, and continuity measurements, insert the red test lead into the "VΩmA" jack.
- For high current (up to 10A DC) measurements, insert the red test lead into the "10A DC" jack. Ensure the function dial is set to the appropriate current range.

Расми 2: Multimeter with black lead in COM and red lead in VΩmA jack.
5. Дастурҳои истифодабарӣ
The Sealey MM20HV offers 8 functions for various electrical measurements.
5.1. Фаъол/хомӯш
Rotate the central function dial from the "OFF" position to any desired measurement function to turn the multimeter on. To turn off, rotate the dial back to "OFF".
5.2. Андозагирии ҳаҷми ҷараёни доимӣtage (V=)
- Insert the black lead into the "COM" jack and the red lead into the "VΩmA" jack.
- Set the function dial to the desired DC Voltage range (e.g., 200mV, 2V, 20V, 200V, 600V). If the voltage is unknown, start with the highest range and decrease as necessary.
- Санҷишҳои санҷиширо дар тамоми ҷузъ ё схемаи ченшаванда пайваст кунед.
- Ҷилди хонедtagарзиши e дар экрани LCD.
5.3. Андозагирии AC Voltagд (V~)
- Insert the black lead into the "COM" jack and the red lead into the "VΩmA" jack.
- Set the function dial to the desired AC Voltage range (e.g., 200V, 600V).
- Зондҳои санҷиширо дар саросари AC пайваст кунедtagд манбаъ.
- Ҷилди хонедtagарзиши e дар экрани LCD.
5.4. Measuring DC Current (A=)
Огоҳӣ: Never connect the multimeter in parallel with a voltage source when measuring current. Always connect in series with the load.
- Insert the black lead into the "COM" jack.
- For currents up to 200mA, insert the red lead into the "VΩmA" jack. For currents up to 10A, insert the red lead into the "10A DC" jack.
- Set the function dial to the appropriate DC Current range (e.g., 2mA, 20mA, 200mA, 10A).
- Занҷираеро, ки ҷараён бояд чен карда шавад, кушоед ва мултиметрро пай дар пай пайваст кунед.
- Арзиши ҷорӣро дар дисплейи LCD хонед.
5.5. Measuring Resistance (Ω)
Огоҳӣ: Пеш аз чен кардани муқовимат, боварӣ ҳосил кунед, ки занҷир аз барқ хомуш карда шудааст ва ҳама конденсаторҳо холӣ шудаанд.
- Insert the black lead into the "COM" jack and the red lead into the "VΩmA" jack.
- Set the function dial to the desired Resistance range (e.g., 200Ω, 2kΩ, 20kΩ, 200kΩ, 2MΩ).
- Зондҳои санҷиширо ба қисме пайваст кунед, ки муқовимати он бояд чен карда шавад.
- Қимати муқовиматро дар экрани LCD хонед.
5.6. Санҷиши давомнокии шунавоӣ
This function allows for quick checks of circuit continuity with an audible tone.
- Insert the black lead into the "COM" jack and the red lead into the "VΩmA" jack.
- Set the function dial to the continuity symbol (often shared with diode test).
- Санҷишҳои санҷиширо тавассути схема ё ҷузъ пайваст кунед.
- An audible tone indicates continuity (low resistance). The display will show the resistance value.
5.7. Diode/Transistor Verification
This function allows for testing diodes and transistors.
- Insert the black lead into the "COM" jack and the red lead into the "VΩmA" jack.
- Set the function dial to the diode symbol.
- For diode testing, connect the red probe to the anode and the black probe to the cathode. The display will show the forward voltage drop. Reverse the probes; the display should show "OL" (Open Loop) for a good diode.
- For transistor (hFE) testing, insert the transistor leads into the appropriate NPN or PNP sockets on the multimeter. The display will show the hFE value.
5.8. Measuring Temperature (°C)
The multimeter includes a thermocouple for temperature measurements.
- Remove the test leads from the input jacks.
- Insert the thermocouple plug into the "VΩmA" and "COM" jacks, observing polarity if indicated.
- Set the function dial to the "°C" range.
- Place the tip of the thermocouple on or near the object whose temperature is to be measured.
- Read the temperature value in Celsius on the LCD display.
5.9. Функсияи нигоҳдории маълумот
Press the "HOLD" button (typically a green button on the front panel) to freeze the current reading on the display. Press it again to release the hold and resume live readings.
6. Нигоҳдорӣ
6.1. Тозакунӣ
Ҳолатро бо таблиғ тоза кунедamp cloth and mild detergent. Do not use abrasives or solvents. Ensure the device is off and disconnected from any circuits before cleaning.
6.2. Иваз кардани батарея
When the battery indicator appears on the display, replace the batteries as described in Section 4.1. Always use fresh AAA batteries.
6.3. Иваз кардани сӯзишворӣ
If the current measurement function stops working, the fuse may need replacement.
- Ensure the multimeter is turned off and all test leads are disconnected.
- Remove the battery compartment cover and batteries.
- Locate the fuse(s) inside the compartment. The MM20HV typically uses a 200mA/250V fast-blow fuse for the mA range and a 10A/250V fast-blow fuse for the 10A range.
- Carefully remove the old fuse and replace it with a new fuse of the exact same type and rating.
- Replace the batteries and battery compartment cover.
Муҳим: Never use a fuse with a different rating or bypass a fuse. This can damage the multimeter and pose a serious safety hazard.
7. Баррасии мушкилот
| Мушкилот | Сабаби эҳтимолӣ | Ҳалли |
|---|---|---|
| Намоиш ё намоиши хира | Батареяҳои мурда ё кам | Replace batteries (Section 4.1) |
| Хониши нодуруст | Incorrect range selected, poor lead connection, damaged leads | Select appropriate range, ensure leads are fully inserted, inspect leads for damage and replace if necessary |
| Андозаи ҷорӣ кор намекунад | Пӯшидани сӯзишворӣ | Replace fuse (Section 6.3) |
| "OL" (бори изофабор) нишон дода мешавад | Measurement exceeds selected range, open circuit (for resistance/continuity) | Select a higher range, check circuit for breaks |
8. Мушаххасоти
The following table outlines the technical specifications for the Sealey MM20HV Digital Multimeter.
| Мушаххасоти | Арзиш |
|---|---|
| Модели рақами | MM20HV |
| Бренд | Сили |
| Функсияҳо | 8 (AC/DC Voltage, DC Current, Resistance, Temperature, Audible Continuity, Diode/Transistor Verification) |
| Ҷилди ACtage (Accuracy) | 200V, 600V (±2%) |
| Ҷилди DCtage (Accuracy) | 200mV, 2V, 20V, 200V, 600V (±0.5% to ±0.8%) |
| DC Current (Accuracy) | 2mA, 20mA, 200mA, 10A (±1% to ±2%) |
| Resistance (Accuracy) | 200Ω, 2kΩ, 20kΩ, 200kΩ, 2MΩ (±0.8% to ±1%) |
| Диапазони ҳарорат | Up to 1000°C (with thermocouple) |
| Манбаи нерӯ | 2 x батареяҳои AAA |
| Вазни ашё | 0.29 Килограмм (тақрибан 10.2 унсия) |
| Андозаҳо (L x W x H) | 1.97 x 4.33 x 6.18 инч |
| Стандарти бехатарӣ | IEC 1010 |
Эзоҳ: Мушаххасот бояд бе огоҳӣ тағир дода шаванд.
9. Кафолат ва дастгирӣ
For information regarding warranty coverage, technical support, or service, please refer to the warranty card included with your product or contact Sealey customer service directly. Contact details are typically available on the manufacturer's official webсайт.