M2000C 2nd Generation
Multi-functional
Air Quality Detector User Manual
Factors Affecting Air Quality
![]() |
PM2.5 (Particulate Matter 2.5) refers to fine particles with a diameter of 2.5 micrometers or less. Due to its tiny size, PM2.5 can be absorbed into bloodstream and the lungs, so that long-term exposure to high concentration of PM2.5 environment may cause eye and nose irritation, cough, asthma, emphysema, lung disease, heart attacks, cancer and etc. |
![]() |
PM10 (Particulate Matter 10) refers to particles with a diameter of 10 micrometers or less. Due to the larger size, it’s inhalable but penetrates no further than bronchi as larger particles can be filtered out by cilia and mucus of nose and throat. It is normally considered as less harmful to health than PM2.5. |
![]() |
CO2 (Carbon dioxide) is a colorless and odorless gas that is usually derived from the breath of humans and animals. High CO2 concentration means that fresh air or ventilation is required, otherwise it may cause problems such as drowsiness, dizziness, loss of attention, and cognitive impairment. |
Important!
- Do not place the detector in highly polluted environments (concentration of CO2>2500ppm or particle>500pg/m3) for a long time to avoid damage to the sensor.
- Do not cover the air inlet/outlet during detection, or let fluff or hair enter the detector.
- Do not use the detector in humid environments with a strong odor.
- Do not make contact with organic solvents, such as glue/adhesives/paint/alcohol, etc.
- If the battery level shows 0, please charge the detector promptly to avoid effects during use (also chargeable when turned off).
Overview
- Buzzer Status
- Measuring Status
- Display
- Menu Button
- Increase/Up Button
- USB Port
- Date & Time
- Power Level
- Back Button
- Power/OK Button
- Decrease/Down/Switch (Start/Pause) Button
Operation
Warning!
- First use or unused for a long time: Please put it outside for over 6 hours for calibration.
- Indoor use: Keep the room/area airtight for 10 minutes to obtain more accurate results.
- When calibrating the CO2 sensors, please adjust the detector to the calibration interface and place it outdoors in a cool and ventilated place for 3o minutes. Detection results will be much more accurate.
- ON
Press and holdfor 2 seconds to turn on the detector.
- Detection
Pressto enter the main menu interface (see the figure below), then press
or
to locate the option to view or set and press
to confirm.
Note: It takes about 3 minutes for the CO2 sensor to warm up and then enter detection status.
View or Set PM2.5/CO2
In each interface, press to display more functions. Take the CO2 interface, for example, press
button, and you may see the following function options:
a. Pause measuring: Pause or restart detecting CO2.
b. Turn on alarm sound: Mute / Unmute the buzzer.
c. Display the data: Display (or not) the CO2 concentration curve.
d. Alarm value setting: Set a high alarm limit.
Operation: Press or
button to adjust the value and press
to switch digits. Then press Save
to save the setting and exit the interface, or press Exit
to exit without saving the setting (See the figure below).
e. Calibration zero: Calibrate the sensor to zero (no such function for PM2.5 interface). Take CO2 interface below for example:
f. EXIT: Exit the current interface.
View all info
The View all info interface displays all the detected data including the concentration of PM2.5, PM10, CO2, number of particles, temperature and humidity. Press to switch between °C and °F. See the figures below.
Press
to pause or detect; press sr
to back to the main menu interface.
History
The History interface includes Storage interval and Data export functions (See the figure below).
Operation: Press
or
to switch between Storage interval and Data export, then press
to enter the corresponding interface.
a. Storage interval: Press:to switch between digits, Save and Exit. When you select a digit, press
or
to adjust the value to your desired storage interval among 1, 5, 10, 30, and 60 minutes, then locate the option to Save and press
to save the setting and exit the interface; or locate the option to Exit and press
to exit the interface without saving the setting.
b. Data export: In this interface, you will see the following tips.
If connected to the computer successfully by the USB cable, the detector will pop up a tip USB connection successfully; If not, it will remind you of the failure (See the figures below).
After connecting successfully, the detector will generate in the computer a removable storage device Temtop, which contains a folder named History. The history folder includes a CSV format file listing the date and time, PM2.5, PM10, and CO2 concentration (see the figure). Please save it to your computer for viewing.
Date | PM2.5 | PM10 | Co2 | |
2019/10/28 15:5 | 6 | 10 | 2038 | |
2019/10/28 15:10 | 7 | 11 | 1795 | |
2019/10/28 15:15 | 8 | 14 | 1914 |
After the data is copied and viewed, please press to exit and restart the detector (See the figure below).
Set
The Set interface displays 5 options below. Operation: Press or
to select the desired option; press
to enter the interface.
a. Date and time: Allows customized setting of year, month, date, and time (See the figure below).
Operation: Press or
to adjust time and press
to switch to the next digit. Then press
to switch to Save or Exit. Press
to finish the settings and exit the interface.
b. Alarm value: Set a high alarm limit for PM2.S, or CO2 concentration (See the figure below).
Operation: Press or
set a high alarm limit for PM2.S, or CO2 concentration, and press
to switch to the next digit. Then press
to switch to Save or Exit. Press
to finishes the settings and exit the interface.
c. Help: View the help information for using the detector (See the figure below).
Operation: Press or
to view the information that helps you use the detector; press
back to Set interface.
d. Restore: Reset to the default parameters (See the figure below).
Operation: Press to switch to Restore or Exit. Press
to confirm the settings and exit the interface. If reset, all the customized settings will automatically turn to the default.
e. Language: Set Chinese or English as a displayed language (See the figure below).
Operation: Press to switch between Chinese and English, press
to confirm; then press
again to switch to Save or Exit; press
to finish the settings and exit.
3. Multipoint Detection Repeat 2 Detection at multiple points in the targeted area to get a more comprehensive understanding of your air quality.
4. OFF Under normal operating status, press and hold for 2 seconds to turn off the detector. It will be auto-off after 1 hour of inactivity.
Note: The auto-off function is invalid in the Histogram interface.
Specifications
Model | M2000C 2nd |
Dimensions | 223.5×73.5×37.5mm / 8.8×2.8×1.4in. |
Battery capacity | 3000mAh |
Battery life | 6-8h |
Input | DC5V; 1A |
Display | TFT color screen |
Operation environment | Temperature range: 0-50°C (32-122°F) Humidity range: 0-90% RH Atmospheric pressure condition: 1 atm |
PM2.5 | Sensor: Laser PM sensor Measuring range: 0-999 pg/m3 Resolution: 01 pg/m3 Accuracy: ±10 pg/m3(0-100 pg/m3) ±10%(100-500 pg/m3) |
PM10 | Sensor: Laser PM sensor Measuring range: 0-999 pg/m3 Resolution: 01 pg/m’ Accuracy: ±15 pg/m3(0-100 pg/m’) ±15%(100-500 pg/m3) |
Carbon dioxide (CO2) | Sensor: Non-Dispersive Infrared (NDIR) CO2 sensor Measuring range: 0-5000 ppm Resolution: 1 ppm Accuracy: ±(50 ppm + 5% reading) |
FAQ:
Q: Why is the data reading very high/over-range after the detector is turned ON?
A: As being packed in ink printed package box over time may interfere with the sensor due to the remaining organic volatile residue inside the package. Therefore, after unpacking, please put the detector in a ventilated place to help accelerate its data recovery.
Q: Why is data reading unstable?
A: As airflow in the environment is changing, the distribution of organic matter concentration may be uneven. Temp recommends trying again in low airflow areas.
Q: Why is the test result abnormal or below normal?
A: (1) Please check whether the air inlet or outlet has been covered or fluid is in.
(2) Gently shake the detector during detection to increase the interaction with the surrounding air.
(3) The sensor maybe not have recovered. Please place the detector outdoors for ventilation.
Q: Can the calibration be accelerated if the detector is facing the outlet of air conditioner/fan?
A: No. The temperature difference or airflow speed at the air conditioner/fan outlet is relatively high, which may cause condensation or temperature changes on the sensor, affecting its detection performance. Please put the detector outdoors in a cool ventilated place.
Q: Why is the PM2.5 reading constantly changing?
A: As PM2.5 concentration in the environment is changing all the time not only due to environmental factors like changes in airflow, humidity, wind direction and etc. but also due to common pollutant sources like smoking, cooking; exhaust emissions from vehicles, smoke from burning coal/chimneys/furnaces and etc. All of these may influence the PM2.5 concentrations and give differences in the readings.
Q: Which reference standards have been used to indicate the pollution levels?
A: Reference Standards for Particles and CO: are shown below.
Status/ Pollutant | Good | Moderate | Unhealthy for Sensitive Groups |
Unhealthy | Very Unhealthy |
Hazardous |
PM2.5 (pg/m3) |
≤12 | 12.1∼35.4 | 35.5∼55.4 | 55.5∼150.4 | 150.5∼250.4 | ≥250S |
PM10 (Pg/m3) |
≤54 | 54.1∼154 | 154.1∼255 | 255.1∼354 | 354.1∼424 | ≥425 |
CO2 (ppm) |
≤700 | 701∼1000 | 1001∼1500 | 1501∼2500 | 2501∼5000 | ≥5001 |
What’s Included
Detector x1
USB Cable x1
User Manual x1
Warranty
Temp warrants the included item for1 a year from the date of original purchase. The item can be exchanged or returned within 30 days if the defect is not caused by artificial damage. )
Item | Warranty Period | Service Mode |
Detector | 1 year | Send to us |
Accessories | N/A | N/A |
Before returning or sending for repair, please check if the following items are ready:
Detector & Accessories | Complete Package | Proof of Purchase* | Gift (if any) | |
Return | V | V | V | V |
Exchange | V | V | V | |
Repair | V | V |
* Including invoice, order number, etc.
Temp warranty does NOT include
- Malfunction or damages caused by artificial damage or modification
- Other deliberate damages.
- Damages caused by force majeure events.
Elltech Technology, Inc.
2528 Qume Dr, Ste 2
San Jose, CA 95131 USA
Tel: +1408-898-2866
Sales: sales@temtopus.com
Website: www.temtopus.com
Elitech (UK) Limited
Unit 13, Greenwich Centre Business Park
53 Norman Road, London, SE10 9QF UK
Tel: +44 (0)208-858-1888
Sales: sales@elitech.uk.com
Website: www.elitecheu.com
Elitech Brasil Ltda
R. Dona Rosalina, 90 – Igara, Canoas – RS,
92410-695, Brazil
Tel: +55 (51)-3939-8634
Sales: brasil@e-elitech.com
Website: www.elitechbrasil.com.br
Documents / Resources
![]() |
Temtop M2000C 2nd Generation Multi-Functional Air Quality Detector [pdf] User Manual M2000C, 2nd Generation Multi-Functional Air Quality Detector |