Teejet 73 Series Addflow User Guide
Teejet 73 Series Addflow

CONNECTIONS TABLE

CONNECTIONS TABLE

Description Connection
Carrier Flow Meter Supply 12 V
Signal S2
Ground Icon
Liquid Flow Sensor Supply (Brown) 12 V
Signal (Black) S4
Ground (Blue) Icon
Master Signal (12V is spraying) Supply (Brown) Icon
Signal (Black) S5

CONNECTIONS TABLE

Jumpers Position
J7 S1 R
J9 S4
J8 S5 if External masterS5R if always active

GENERALITIES

Function Key Description
1. Power On Symvol The unit will power on and show the first working screen. inj. Rate2.00%
Scren Display
2. Power Off Symvol The unit will power off.
3. Selection of Working Screen Symvol

FUNCTIONALITY

Function Display Comments Possible Actions
1. Injection Dose Rate Scren Display This is the desired dose rate for the injected product. It is set as a percentage of the main carrier flow. Symvol to change dose Symvolrateto select another display value
2. Injection Flow Scren Display This is the actual flow of injected product. Symvolto select another display value
3. Carrier Flow Scren Display This is the actual main carrier flow. Symvol to select another display value
4. Injected Volume Scren Display This is the injected volume counter. Symvol to select another display value
Symbol to clear the counter

PRIMING

To activate priming, push the Pump switch to CAL

PRIMING

The pump will then start running and the display will show pumped volume
Scren Display

When predefined volume has been injected, the display will go back to the previous working screen.

ALARMS

Function Display Comments Possible Actions
1. Pump Not Running Scren Display Alarm message will appear when injectionstarted but the pump is not turning. Check cabling and pump
2. No Liquid Injected Scren Display This means that no liquid is injected. Alarm message will appear only if the liquid presence sensor is mounted. Check plumbing and//or fill the tank.

PROGRAM

Function Display Possible Actions Comments
Access/Exit Push Symvol for 3 seconds Master must be off
1. Carrier Flow Meter Scren Display  to select another step
Symvol to enter carrier flow meter calibration (1.1)
Push Symvol for 3 seconds to escape program
1.1 Scren Display Symvol to modify value Symvol to validate value Main carrier flow meter calibration in pulses/litre
2. Injection Pump Scren Display Symvol to select another step
Symvol to enter calibration (2.1)
Push Symvol for 3 seconds to escape program
2.1 Injection Pump Type2.2 Injection PumpCalibration Scren Display Symvol to modify value
Symvol to validate value (2.2) to escape (2)
Push Symvol for 3 seconds to escape program
Choices are:
  • Peristaltic
  • Piston 1 (head)
  • Piston 2 (heads)
  • Piston 3 (heads)
  • Piston 4 (heads)
Scren Display Symvol to modify valve
Symvol to validate value (2) to start automatic calibration
(see “7. Pump Automatic Calibration” on page 4)
This is the complete pump calibration (all heads together). Units are pulses/millilitre. Average value is 3.00 per head for a piston pump.
3. Prime Calibration Scren Display Symvol to select another step
Symvol to enter calibration (3.1)
Push Symvol for 3 seconds to escape program
3.1 Scren Display Symvol to modify value
Symvol to validate value
Symbol to start Automatic calibration(see “8. Prime Automatic Calibration” on page 4)
This is the volume that must bepumped to prime the system.

PUMP AUTOMATIC CALIBRATION

Function Display Possible Actions Comment
2.2 Injection Pump Calibration Scren Display Symvol to modify value
Symvol to validate value (2)
Symbol to start Automatic calibration
This is the complete pump calibration (all heads together.) Units are pulses/millilitre. Average value is 3.00 per head for a piston pump.
2.2.1 Scren Display Symbol to exit Automatic calibration Push on the CAL switch on the pump to start the calibration. Collect the pumped volume. Keep the CAL switch pushed until calibration is finished. Pump must be ready to inject (tubes filled).
2.2.2 Scren Display Display shows the counted pulses from the pump Release the CAL switch when enough pulses have been counted.
2.2.3 Scren Display Symvol to set the pumped volume Symvol to validate Release the CAL switch when enough pulses have been counted.

PRIME AUTOMATIC CALIBRATION

Function Display Possible Actions Comments
3.1 Prime Calibration Scren Display Symvol to modify value
Symvol to validate value
Symbol to start Automatic calibration
This is the volume that must be pumped to prime the system.
3.1.1 Scren Display Push on the CAL switch on the pump to start the calibration. Keep the CAL switch pushed until calibration is finished.
3.1.2 Scren Display Display will show injected volume. Release the CAL switch when system has been primed.
Symvol to validate

www.teejet.com

98-05355-EN R1 English International
© TeeJet Technologies 2022