TeeJet TECHNOLOGIES IC45-DYNARATE Sprayer Job Computer User Guide

IC45-DYNARATE Sprayer Job Computer

Specifications

  • Product Name: IC45-DYNARATE
  • Product Type: Sprayer Job Computer
  • Brand: TeeJet
  • Trademark: Unless otherwise noted, all other brand or product
    names are trademarks or registered trademarks of their respective
    companies or organizations.

Product Usage Instructions

Important Safety Information

Safety Alert Symbol Definitions:

  • DANGER! This symbol is reserved for the most
    extreme situations where serious personal injury or death is
    imminent.
  • WARNING! This symbol indicates a hazardous
    situation that could result in serious personal injury or
    death.
  • CAUTION! This symbol indicates a hazardous
    situation that could result in minor or moderate personal
    injury.
  • NOTE: This symbol addresses practices in which
    the operator should be aware.

General Warnings and Precautions

Detailed warnings and precautions related to electrical hazards,
pressurized systems, chemical handling, equipment safety,
maintenance, service, harness cable and hose safety, touch screen
care, and recommended replacement parts are provided in the
manual.

Did You Know…

The origins of the TeeJet brand and the significance of the tee
shape in their spray tips.

Initial Information

Organizational details of screen areas, information areas, ECU
icon, graphic indicators, speed information, function keys,
navigation, and description of function keys are provided for user
understanding.

FAQ

Q: How do I toggle the spraying ON/OFF?

A: To toggle the spraying ON/OFF, locate the key at the bottom
right of the screen in work mode. The color of the key indicates
its status: Grey = OFF / Green = ON.

“`

IC45-DYNARATE
QUICK START GUIDE
SPRAYER JOB COMPUTER

Copyrights © 2025 TeeJet Technologies. All rights reserved. No part of this document or the computer programmes described in it may be reproduced, copied, photocopied, translated, or reduced in any form or by any means, electronic or machine readable, recording or otherwise, without prior written consent from TeeJet Technologies.
Trademarks Unless otherwise noted, all other brand or product names are trademarks or registered trademarks of their respective companies or organizations.
Limitation of Liability TEEJET TECHNOLOGIES PROVIDES THIS MATERIAL “AS IS” WITHOUT WARRANTY OF ANY KIND, EITHER EXPRESSED OR IMPLIED. NO COPYRIGHT LIABILITY OR PATENT IS ASSUMED. IN NO EVENT SHALL TEEJET TECHNOLOGIES BE LIABLE FOR ANY LOSS OF BUSINESS, LOSS OF PROFIT, LOSS OF USE OR DATA, INTERRUPTION OF BUSINESS, OR FOR INDIRECT, SPECIAL, INCIDENTAL, OR CONSEQUENTIAL DAMAGES OF ANY KIND, EVEN IF TEEJET TECHNOLOGIES HAS BEEN ADVISED OF SUCH DAMAGES ARISING FROM TEEJET TECHNOLOGIES SOFTWARE.

IC45-DYNARATE QUICK START GUIDE
IMPORTANT SAFETY INFORMATION
FOREWORD
This guide is intended for the user of the sprayer for the current operations of treatment of the crops or fertilization of the fields. It is considered that the settings inherent to the tractor, the sprayer, the ISOBUS terminal (TECU), the calibrations and the advanced settings have been carried out beforehand in the workshop. Instructions for these operations, which are limited to qualified personnel from agricultural machinery manufacturers and dealers, are available from TeeJet technologies. All safety related and operating instructions should be read before the system is operated. Safe operation of machinery is the operators responsibility. Safety procedures must be posted close to the equipment and clearly visible to and legible by the operator. Safety procedures should meet all company and local regulations, as well as MSDS-requirements. For assistance, please contact a local dealer.
Safety Alert Symbol Definitions:
DANGER! This symbol is reserved for the most extreme situations where serious personal injury or death is imminent.
WARNING! This symbol indicates a hazardous situation that could result in serious personal injury or death.
CAUTION! This symbol indicates a hazardous situation that could result in minor or moderate personal injury.
NOTE: This symbol addresses practices in which the operator should be aware.
GENERAL WARNINGS AND PRECAUTIONS
DANGER!
· Read and follow instructions. If instructions are unclear after reading the manual, please contact a local dealer. · Keep children away from equipment. · Do not operate machinery under the influence of alcohol or any illegal substance. · Some systems include a fan heater. Never cover the heater otherwise there will be a serious danger of fire!
98-01632-EN R0 3

IC45-DYNARATE QUICK START GUIDE
WARNING! ELECTRICAL / SHOCK HAZARDS
· Before working on any particular component, make sure that all power supplies have been switched off and cannot be accidentally switched on.
· Disconnect power leads before using an arc welder on equipment or anything connected to the equipment. · Systems including frequency drives have a risk of electric shock due to residual voltage. It is not permissible to open the
equipment neither to disconnect the system or any quick connection until 5 minutes after the power has been removed. · Only operate the system from the power source indicated in the manual. If you are not sure of the power source, consult
qualified service personnel. · Do not use a high pressure cleaner to clean electrical components. This could damage electrical components and
subject the operator to risk of electrical shock. · The electrical supply to the equipment must be properly routed and connected to the equipment. All connections must
meet the specified requirements.
WARNING! PRESSURIZED HYDRAULIC SYSTEMS
· Always wear personal protective equipment (PPE) when performing work on hydraulic systems. · Adhere to the machine manufacture’s approved maintenance instructions when working on the hydraulic system. · Always turn equipment off when working on the hydraulic system. Take appropriate precautions when opening systems
that have been previously pressurized. · Be aware that hydraulic oil may be extremely hot and under high pressure.
WARNING! CHEMICAL HANDLING
· Always wear PPE when handling any chemical substance. · Always follow safety labels and instructions provided by the chemical manufacturer or supplier. · The operator should have full information on the nature and the quantity of the material to be distributed. · ADHERE TO FEDERAL, STATE AND LOCAL REGULATIONS REGARDING THE HANDLING, USE OR DISPOSAL
OF AGRICULTURAL CHEMICALS.
WARNING! PRESSURIZED SPRAY SYSTEM
· It is important to recognize proper safety precautions when using a pressurized spray system. Fluids under pressure can penetrate skin and cause serious personal injury.
· The system pressure should never exceed the lowest rated component. Always know your system and all component capabilities, maximum pressures and flow rates.
· Filters can only be opened when the manual valves in front of and behind the filter are in closed position. If any appliance has to be taken out of the piping, manual valves in front of and behind this appliance have to be in closed position. If they are reinstalled, make sure that this happens correctly, that this apparatus is well aligned, and that all connections are tight.
· The plumbing supply to the equipment should meet all company and local regulations and must be properly routed and connected to the equipment. All connections must meet the specified requirements
· It is advised to drain and purge the liquid train when the equipment shall not be used for a longer period of time.
WARNING! AUTO STEERING SAFETY
· To prevent serious personal injury or death from being run over by the vehicle or automated motion of the steering system, never leave the vehicles operator seat with the system engaged.
· To prevent serious personal injury or death from being run over by the vehicle or automated motion of the steering system, verify the area around the vehicle is clear of people or obstacles before startup, calibration, tuning or engaging the system.
· Make sure equipment is tightly secured to the proper components. · Never drive on public roads with system engaged.
4 www.teejet.com

IC45-DYNARATE QUICK START GUIDE
CAUTION! EQUIPMENT SAFETY, MAINTENANCE, AND SERVICE
· The equipment should be operated only by properly trained, qualified personnel. They must have proven their skills in the operation of the equipment.
· Before using the equipment, the operator has to check if the equipment is in good condition and can be used safely. If not, the equipment cannot be used.
· All necessary PPE must be readily available to the operator at all times. · Routinely check the system and components for wear and damage. Replace or repair when necessary. · Only qualified authorized experts are allowed to repair or maintain the installation. The maintenance and operating
instructions shall be rigidly observed and followed. · A complete manual for the equipment must be available to the operator or maintenance technician at all times.
CAUTION! HARNESS CABLE AND HOSE SAFETY
· Routinely check all harness cables and hoses for damage or wear. Replace or repair when necessary. · Do not route harness cables and hoses with sharp bends. · Do not strap harness cables and hoses to lines with high vibration or spikes in pressure. · Do not strap harness cables and hoses to lines transporting hot fluids. · Protect harness cables and hoses from sharp objects, equipment debris, and material buildup. · Allow sufficient length for harness cables and hoses to have free movement on sections that move during operation, and
be sure that harness cables or hoses do not hang below the equipment. · Allow sufficient clearance for harness cables and hoses from implement and machine operational zones. · When cleaning equipment, protect harness cables from high pressure wash.
NOTE: TOUCH SCREEN CARE
· Keep sharp objects away from the touch screen device. Touching the screen with a sharp object could result in damage to the display.
· Do not use harsh chemicals to clean the console/display. The correct way to clean a console/display is to use a soft damp cloth or anti-static wipe, similar to cleaning a monitor on a computer.
NOTE: RECOMMENDED REPLACEMENT PARTS
· The system has been designed with components that work together to provide the best system performance. When the system requires replacement parts, only TeeJet recommended components should be use to maintain proper system operation and safety.
Safety information
TeeJet Technologies is not responsible for damage or physical harm caused by failure to adhere to the following safety requirements. As the operator of the vehicle, you are responsible for its safe operation. The IC45 in combination with any assisted/auto steering device is not designed to replace the vehicle’s operator. Do not leave a vehicle while the assisted/automatic steering is engaged. Be sure that the area around the vehicle is clear of people and obstacles before and during engagement. The IC45 is designed to support and improve efficiency while working in the field. The driver has full responsibility for the quality and work related results. Disengage or remove any assisted/auto steering device before operating on public roads.
98-01632-EN R0 5

IC45-DYNARATE QUICK START GUIDE
DID YOU KNOW…
The origins of the TeeJet brand can actually be found in our spray tips? If you look at the side profile of the spray tip below, you’ll notice its distinctive “tee” shape. That characteristic, combined with our “Jet” family of names, is how the TeeJet name was born.
6 www.teejet.com

IC45-DYNARATE QUICK START GUIDE

INITIAL INFORMATION
ORGANIZATION OF SCREEN AREAS
2 INFORMATION AREAS
Customizable to display numerical indicators: dose, flow rate, pressure, applied area etc.
ECU ICON
This icon indicates that the IC45 ECU is connected to the terminal. NOTE: You may sometimes have
multiple ECU’s if you have multiple ISOBUS system installed.
GRAPHIC INDICATORS
Volume in tank, sections, pressure, droplets.

SPEED INFORMATION

FUNCTION KEYS AND NAVIGATION

3 INFORMATION AREAS
Customizable to display numerical indicators: dose, flow rate, pressure, applied area etc.

STATUS BAR
Contains icons showing the state of currently active functions.

Description of Function Keys
Key set may be different depending on your sprayer’s features.

Spraying OFF/ON

Toggle OFF/ON

This key is always available at the bottom right of the screen in work mode. Its colour indicates its status: Grey = OFF / Green = ON

In multiple menus, there are keys with buttons at the bottom. The key pictograms’ colour, as well as the colour of the slide behind the toggle, is grey when it is turned OFF.
When turned ON, the key pictograms’ colour will turn white, and the slide behind the toggle will turn green.

98-01632-EN R0 7

IC45-DYNARATE QUICK START GUIDE
GETTING STARTED
SPEED SOURCE
Enter the Main Menu Machine
Job Settings
Operation
Speed Source Select the desired Speed Source:
­ Automatic: selects the best source available (GNSS if available)
­ Ground Based: selects the GNSS speed ­ Wheel Based: selects the tractor’s speed ­ Vehicle Based: selects tractor’s on-board
sensor (radar…) ­ Implement: selects the sprayer’s wheels
sensor Ensure that the source used is the preferred one and see the full manual for how to calibrate it, if the speed is incorrect.
8 www.teejet.com

PRESETTING NOZZLES
Go to the Main Menu

IC45-DYNARATE QUICK START GUIDE

Machine

Nozzle Presets
The Nozzle Presets section contains 5 pages that can store up to 5 nozzles installed on the machine. NOTE: The preset nozzles will appear in the nozzle
list when entering the spray parameters in the JOB WIZARD.
· Press Nozzle Series to choose the nozzle type.
· Press Nozzle Capacity to select the nozzle size.

98-01632-EN R0 9

IC45-DYNARATE QUICK START GUIDE
SELECT NOZZLE FOR SPRAY JOB
Once you have preset your nozzle types and capacities, you can easily change to another of 5 presets, using the Pressure/Droplet Size Bar.
10 www.teejet.com

IC45-DYNARATE QUICK START GUIDE
DID YOU KNOW…
In 1981, TeeJet Technologies introduced the Quick Teejet® system, which was adopted by the entire industry. The 1/4-turn quick attach cap and body system significantly reduced the effort required to install or change spray tips, while also providing automatic spray pattern alignment across the boom for optimum distribution
98-01632-EN R0 11

IC45-DYNARATE QUICK START GUIDE
SIMULATED SPEED How to Use Simulated Speed
This key activates or deactivates the simulation mode. The key is only available when no other speed source is available.

NOTE: Simulated speed will be disabled, if there is another speed source, with a speed higher than 0.0 km/h.
This key toggles between slow and fast simulated speed. The pictograms change colour to indicate the selected speed, with green indicating the selected speed.

NOTE: Using GPS speed may cause slight movements, which will disable the simulated speed.
The status of the simulation mode is displayed in the status bar: ­ Simulation active: The icon (tortoise or hare) corresponding to the selected simulated speed, is visible in the status bar. ­ Simulation inactive: The icon (tortoise or hare), won’t be present in the status bar.
Set Low and High Simulated Speeds

Enter the Main Menu Machine

Operation

Job Settings 12 www.teejet.com

Press the lines to change the speed settings of the low (tortoise) or high (hare) speeds.

IC45-DYNARATE QUICK START GUIDE
TARGET RATE AND TANK AGITATION
Selecting the Target Rate
Press JOB WIZARD key from Work Screen. Press Target Rate line to open screen for entering desired target rate.
Tank Agitation
NOTE: Agitation mode may not be available on all sprayers. For more information, contact your manufacturer.
The tank agitation system performed by the spray pump can be activated/deactivated both from the Sprayer Job computer, as well as other physical locations, according to the ongoing task:
­ Dedicated key on the work screen/Job Wizard menu. ­ Joystick, switch box and DynaFill Terminal.
STARTING AGITATION FROM WORK SCREEN:
Pressing the key activates/deactivates the agitation system.

OFF

ON

The status of the agitation is also displayed in the status bar. The icon is visible when the agitation is active. It disappears when it is inactive.

98-01632-EN R0 13

IC45-DYNARATE QUICK START GUIDE

MACHINE PROFILE
Go to the Main Menu
Machine

Nozzle Spacing
Enter value (cm), how far there is between your nozzles.
Shortened Section
Pressing line, activates Shortened Section function, altering your outermost working widths, by the value entered below.

Job settings

Shortened Section Width

Machine Profile

Pressing line, enters value (cm), which your Shortened Section alters your outermost working widths.

Example: If using a 3 meter outermost segment, using Shortened Working Width set to 100 cm, only first 100 cm (1m) of your outermost working widths will be digitally counted.

NOTE: Shortened Section Width set above zero (0) doesn’t turn OFF section. You need to manually turn OFF the nozzles, for physical amount of liquid, to match digitally counted amount.

Section Width
Press the Section you wish to change the numerical value of (cm).

NOTE: Shortened Section Width set to zero (0), will turn OFF entire outermost sections.
Section Turn ON and OFF Time
Section Turn ON Time

Enter time between activating spraying, till liquid physically comes out of sprayer.

Previous Page Next Page
To go to another page, use the Previous Page or Next Page Key.

Function will turn spraying ON before entering spraying area, to ensure full coverage.

The number of pages in this menu, depends on how many sections you have programmed into the device.
NOTE: In our example, we have chosen 40 sections, so 7 pages are available.

Section Turn OFF Time
Enter time between deactivating spraying, till liquid physically stops coming out of sprayer.

Function will turn spraying OFF before exiting spraying area, to ensure full coverage.

14 www.teejet.com

IC45-DYNARATE QUICK START GUIDE
CHOICE OF REGULATION MODE Automatic and Manual Modes
This key on the Work Screen allows you to select the control mode between manual and automatic regulation.

Automatic
Automatic Mode
These keys allow you to adjust the current target rate in configurable steps (1%, 5%, 10%, etc.). Default is 10%.

Manual
Manual Mode
In manual mode, the target rate is adjusted manually by pressing the Rate decrease or increase keys.

Decrease Target Rate

Increase Target Rate

Return to original target rate.

Decrease Rate

Increase Rate

These keys will open or close the control valve and adjust the target rate as desired.

WARNING : Pressure in boom is not controlled automatically, hence it is possible to set the pressure so high that it may damage the sprayer.

The target rate adjustment can be displayed in one of the customizable information areas.

98-01632-EN R0 15

IC45-DYNARATE QUICK START GUIDE
DID YOU KNOW…
The colour-coding system VisiFlo® was developed and introduced by TeeJet Technologies in 1985. By incorporating a colour-coded plastic tip body with a stainless-steel orifice, farmers were able to quickly and easily identify the nozzle capacity. The VisiFlo® colour scheme promptly became the industry standard and was adopted by ISO as the world standard in agricultural tip capacity identification.
16 www.teejet.com

IC45-DYNARATE QUICK START GUIDE
FILLING THE SPRAYER TANK
Tank filling can be done in different ways, depending on the functions supported by your sprayer. Please see the Full IC45 Manual for Further Information.
Filling with the In-Cab Terminal
If your sprayer is equipped with DynaFill, please use the full IC45 manual to learn about using this function. If your sprayer does not have DynaFill capabilities, Follow the steps below.
Press the Fill key or the tank image on the Work Screen to enter the Tank Filling menu. NOTE: You may have to press the Next Page key, if the Tank Filling
key isn’t on the currently viewable page. It is also possible that this key isn’t part of your keyset.
Calculate the required volume in the tank to fulfill the spray job you intend to do. Press the “Desired Content” line and enter the value. If your sprayer does not feature an electrically-controlled fill valve, open the fill valve manually. When the “Actual content” value, equals the “Desired content” value, step back to the sprayer controls and manually turn the fill valve OFF.
Liquid Density
If you are using liquid with a density different than water, pressing the Density Fertilizer line will allow you to enter the Density Factor, of your currently used liquid.
98-01632-EN R0 17

IC45-DYNARATE QUICK START GUIDE

USE OF THE HYDRAULIC FUNCTIONS OF THE BOOM

NOTE: Folding options depend on the sprayer’s configuration.
Boom Lock
Whether driving on the road, folding or unfolding boom, the boom’s pendular suspension must be locked, both for safety and to ensure a proper fixed position.

Entering the Boom Menu

Locked:

Unlocked:

Press to unlock

Press to lock

The key’s padlock icon changes its appearance to indicate the boom lock status.

NOTE: The Boom Lock key may not be displayed on the work screen. It may require either browsing pages using the “Next page” key, or going to the Folding Menu by pressing the Main Menu Key (shown below).

TIP: The “Boom Control” key is always displayed on the main menu if you have hydraulic functions on your sprayer.
This screen may feature several key pages, depending on the sprayer type and configuration.

Whether you have access to the Boom Lock key on your main

Unfolding

screen key-set or not, you will always be able to see the current state

of your Boom Lock, in the Status Bar at the bottom of the page.

To unfold, use the following keys:

As long as the key is pressed, the hydraulic system performs the desired movement and the terminal screen displays an illustration of the moving part colored in blue and with a direction arrow.

18 www.teejet.com

Up / Down

IC45-DYNARATE QUICK START GUIDE
Tilt Left / Right

Use Boom Up and Boom Down to regulate the height of your boom. Use Tilt Up and Tilt Down to regulate tilt of your boom.

Wing Up / Down

Folding

Use Wing Up and Wing Down to regulate the height on one side of your boom.

As long as the key is pressed, the hydraulic system performs the desired movement and the terminal screen displays an illustration of the moving part colored in blue and with a direction arrow.

START SPRAYING
FINAL STEP
When all settings are completed and the sprayer is ready for work, start spraying by pressing the “Spray” key.

The working screen displays the information in real time, the automatic regulation sets the required rate.

98-01632-EN R0 19

IC45-DYNARATE
QUICK START GUIDE
www.teejet.com
98-01632-EN-A4/LT R0 English International © TeeJet Technologies 2025

Documents / Resources

TeeJet TECHNOLOGIES IC45-DYNARATE Sprayer Job Computer [pdf] User Guide
IC45-DYNARATE, IC45-DYNARATE Sprayer Job Computer, Sprayer Job Computer, Job Computer

References

Leave a comment

Your email address will not be published. Required fields are marked *