TECNOPLASTIC - logoTAURUS Float Switch
Instructions
TECNOPLASTIC TAURUS Float Switch - ICON 1TECNOPLASTIC TAURUS Float Switch - TAURUS

TAURUS Mod.01 H07 RN-F 3G1 +50°C +122°F 20m / 65,6ft
H07 RN8-F 3G1 +50°C +122°F 20m / 65,6ft
H07 RN-F 3G1 OIL RES. +50°C +122°F 20m / 65,6ft
Mod.02 H05 RN-F 3X1Icon +50°C +122°F 20m / 65,6ft
Mod.03 H07 RN-F 3X1Icon +50°C +122°F 20m / 65,6ft

TECNOPLASTIC TAURUS Float Switch - TAURUS 1

TAURUS Drink ACS + AD8 3X1Icon +40°C +104°F 20m / 65,6ft

TECNOPLASTIC TAURUS Float Switch - TAURUS 2

TAURUS Fep FFR105OPR5F
4G0.75
+80°C +176°F 20m / 65,6ft
Shift Shift 4G1,5 +80°C +176°F 20m / 65,6ft
Purr PUR – FFR105OP
4G0,75
+80°C +176°F 20m / 65,6ft

Warning icon NOTES: DO NOT TAMPER WITH THE FLOAT SWITCH. THE NON RESPECT OF THE FOLLOWING POINTS WILL AUTOMATICALY CAUSE THE CANCELLATION OF THE WARANTY OF THE PRODUCT

  • Before any operation on the float remember to disconnect the power supply from the main power.
  • Check that the maximum motor power does not exceed the float’s electrical values.
  •  In case of cable damage by the final user or installer, the float must be replaced.
  • Do not make any joint on the cable of the float switch, as immersion of such joints could cause short circuits or electrical shocks.

USE:

Unlike normal floats, the level regulator is used in pairs of two of the same type to regulate water levels to a certain height: one regulates the minimum level and the other regulates the maximum level. A third and fourth regulator can also be used for minimum and maximum alarm respectively. To avoid damaging the cable, we recommend the Fixing Kit (Fig.3)TECNOPLASTIC TAURUS Float Switch - tank fills

TECHNICAL FEATURES:

  • Protection Grade: IP 68
  • Specific weight: 0,95 – 1,05 kg/dm³
  • Features of automatic action: 1B (micro-disconnections in operation)
  • Pollution Degree: 2

TECNOPLASTIC TAURUS Float Switch - Ac�va�on angle

TERMINAL CONNECTIONS:

The upstream circuit must protect the electric wires from the overcurrent. WARNING: lack of protection shall null and void the warrany in the event the float breaks.

  • Mod.01: single function SPST – only emptying or only filling (Fig.1). The grounding wire is always yellow and green.
  • Mod.02 – Mod.03 – Drink – Fen – Shift – Purr: double function SPDT (the fattier can choose the emptying Fig.2 or filling Fig.3 when installing):

Emptying: (Fig.2) when black and brown wires are used, the circuit opens when float is down and closes when the float is up.
Note: the blue/grey wire must be insulated.
Filling: (Fig.3) when black and blue/grey wires are used, the circuit closes when float is down and opens when the float is up.
Note: the brown wire must be insulated.TECNOPLASTIC TAURUS Float Switch - TERMINALTECNOPLASTIC TAURUS Float Switch - fig

EC DECLARATION OF CONFORMITY
This is to declare that the product complies with the following Harmonized Standards and Directives

Directives harmonized standards
Low voltage Directive 2014/35/EU EN 55014-1;
EN 60730-1; EN 60730-2-15;
EN 61000-3-2; EN 61000-3-3; EN 61000-4-4;
EN 61000-4-5; EN 61000-4-6; EN 61000-4-8;
EN 61000-4-11.
Electromagnetic Compatibility Directive 2014/30/EU

The person authorized to compile the Technical File is Mr. Guerrini Castaldo at TECNOPLASTIC Seral.

TECNOPLASTIC TAURUS Float Switch - secknasarcTECNOPLASTIC Seral. Via Calabria, 3-5 – 35020 – Sayonara – Padova – ITALY
Tel: +39 049 8790775 – Fax: +39 049 644773 – www.tecnoplastic.com
REV. January 2022
Type Approved Safety Regular Production Surveillance
www.tuv.com
ID 1111220658
TECNOPLASTIC TAURUS Float Switch - baer code

Documents / Resources

TECNOPLASTIC TAURUS Float Switch [pdf] Instructions
TAURUS Float Switch, TAURUS, Float Switch, Switch

References

Leave a comment

Your email address will not be published. Required fields are marked *