Techcon Systems
TS5322
TS5322D
Adjustable Mini Spool Valve
User Guide
SPECIFICATIONS
TS5322 | TS5322D | |
Size | 4.0″ length X 1.12″ diameter (102mm X 28mm) | 4.0″ length X 1.12″ diameter (102mm X 28mm) |
Weight | 0.311b (139g) | 0.261b (119g) |
Fluid Inlet Port | 1/4″ NPT female | ‘A” NPT female |
Fluid Outlet Port | ‘A” NPT female | Vs” NPT female |
Air Inlet Port | 10-32 UNF | 10-32 UNF |
Auxiliary Air Inlet Port | 10-32 UNF | 10-32 UNF |
Minimum Air Pressure | 70 psi (4.8bar) | 70 psi (4.8bar) |
Maximum Fluid Pressure | 500 psi (34.5bar) | 100 psi (6.9bar) |
Operating Frequency | Exceeds 500 cycles/min. | Exceeds 500 cycles/min. |
Mounting Port | 1/4-20 UNC-2B | 1/4-20 UNC-2B |
Wetted Parts | Type 303 SS, Al., Teflon®, EPR | Type 303 SS, Delrin®, Teflon®, EPR |
UNPACKING AND INSPECTION
Carefully unpack the valve and examine the items contained in the carton.
These will include:
- Valve assembly
- Valve bracket and air hose
- Sample tip kit and fluid line
- User guide
DESCRIPTION
The TS5322 Series Mini Spool Valve is designed to dispense medium to high viscosity fluids with very precise deposits, over a wide range of shot and bead sizes. An internal spring return makes the valve fully adaptable for use with any time/pressure controller. A short opening stroke provides extremely fast, positive shut-off. An external adjustment makes it easy to fine tune “suck-back” level. The TS5322’s compact design allows for mounting flexibility and easy integration into automated applications.
THEORY OF OPERATION
The TS5322 Series Mini Spool Valve is a normally closed spool valve with adjustable “suck-back”. Input air pressure of 70 psi (4.8bar) through port (1) drives the spool assembly (2) forward, opening the material path from the material inlet (3) to the material outlet (4). Relieving the input air pressure allows the spool assembly to travel back to the closing position, ensuring rapid “fail-safe” shut-off of fluid flow
An oil chamber (5) is provided above the upper seal to create an additional liquid seal that will prevent moisture from being carried on the spool. The auxiliary air inlet port (6) is provided so that the valve may be connected for air closing with or without the spring.
SET-UP INSTRUCTIONS
- Connect the fluid reservoir feed tube (1) to the valve inlet port (2).
- Connect the valve air hose (3) to the valve controller or other pneumatic device, which is used to control the valve.
- Connect an appropriate nozzle or dispensing tip (4) to the fluid outlet port.
- Set the valve controller pressure at 70 psi (4.8bar).
- Set the fluid reservoir pressure. Do not exceed 500 psi (34.5bar). For TS5322D, do not exceed 100 psi (6.9bar).
- Ensure all connections are tight.
- Place container under the valve outlet and activate the valve until the fluid flows steady.
The amount of fluid that flows through the valve is determined by:
- Valve open time
- Fluid reservoir pressure
- Dispensing tip size
TYPICAL SYSTEM SET-UP
MAINTENANCE AND CLEANING:
Tool required: O-ring removal tool (P/N TSD1597-7), snap ring pliers.
Normally, purging the valve with appropriate flushing material, or solvent after use is sufficient for cleaning. However, some material may cause a build-up in the valve chamber, in this case periodic and thorough cleaning will be required.
NOTE:
- Make sure the fluid pressure is released before valve is disassembled.
- To replace seals please order seal kit part number: 5322-SEALKIT.
- To repair valve please order valve kit part number: 5322VALVEKIT.
7.1 Cleaning and seal replacement for fluid housing: Refer to figure 5.0
- Release fluid pressure.
- Disconnect fluid line and remove fluid inlet fitting.
- Disconnect valve air hose.
- Hold the fluid housing (6) and rotate the air cylinder (18) counterclockwise.
When completely un-threaded, pull the two valve segments straight apart to separate. - Inspect o-ring (17), replace if damaged.
- Remove four socket head cap screws (12) from the outlet block (11).
- Pull the outlet block (11) away from the fluid housing (6).
- Inspect o-ring (10), replace if damaged.
- Using snap ring pliers, remove retaining ring (8).
- Remove stainless steel washer (9) from fluid housing (6).
- Remove upper seal (14).
- Clean the fluid housing (6), outlet block (11), spool assembly (5), upper and lower seal (13) and (14).
NOTE: Avoid using sharp probes for cleaning. Any nicks or scratches on the seal or the surfaces of the spool assembly may cause leakage - Inspect both upper (14) and lower seals (13), replace seals if damaged found.
- Insert upper seal (14) into fluid housing (6) using the seal insertion tool 5322SIT.
Make sure the o-ring side is facing down. - Insert stainless steel washer (9) and secure with retaining ring (8) using snap ring pliers.
- Insert lower seal (13) into outlet block (11). Make sure the o-ring side is facing up.
- Insert o-ring (10) into outlet block (11).
- Re-install outlet block (11) to fluid housing (6).
- Lubricate o-ring (17) with Bimba HT-99, or equivalent.
- Thread the air cylinder/spool assembly into fluid housing/outlet block assembly. Make sure not to cross thread both parts.
7.2 Cleaning and seal replacement for air cylinder:
- Hold the fluid housing (6) and rotate the air cylinder (18) counterclockwise.
When completely un-threaded, pull the two valve segments straight apart to separate. - Remove end cap (19) by rotating it in counterclockwise direction.
- Using the snap ring pliers, remove the retaining ring (2).
- Pull the spool assembly (5) straight out from the air cylinder (18).
- Remove the compression spring (4).
- Using the snap ring pliers, remove the retaining ring (7).
- Remove the nylon washer (15) from the air cylinder.
- Using o-ring removal tool, remove o-ring (16).
- Replace all o-rings if necessary.
- Lubricate all o-rings with Bimba HT-99, or equivalent.
- Re-install o-ring (16).
- Re-install nylon washer (15) and secure with retaining ring (7) Re-install compression spring (4) into air cylinder (18).
- Thread the air cylinder into fluid housing/outlet block assembly making sure not to cross thread both parts.
- Re-install spool assembly (5) and secure with retaining ring (2).
- Re-install end cap (19).
SPARE PARTS
Valve Rear Section
Recommended lubricant: All o-rings & seals must be lubricated with Bimba HT-99, or equivalent.
ITEM | PART NUMBER | DESCRIPTION | QTY |
1 | TSD1120-2 | Retaining Ring, Small | 1 |
2 | TSD1109-45 | Nylon Washer | 1 |
3 | TD1400-006A | 0-Ring, Buna | 1 |
4 | TSD1400-013A | 0-Ring, Buna | 1 |
5 | TSD 1150-5 | Spring | 1 |
6 | 5322-000-001 | SpooUPiston Assembly | 1 |
7 | TSD1400-208A | Piston 0-Ring, Buna | 1 |
8 | TSD1120-15 | Retaining Ring, Large | 1 |
9 | TSD1400-017A | End Cap 0-Ring, Buna | 1 |
10 | 5520-000-007 | End Cap | 1 |
11 | TSD1002-37 | Air Fitting, 4mm | 1 |
12 | A0100478 | Air Hose/Connector Assembly, 4111111 | 1 |
13 | 5520-000-001 | Air Cylinder | 1 |
14 | 918-000-048 | Mounting Bracket | 1 |
15 | TSD1106-36 | Mounting Screw | 1 |
Valve Front Section
Recommended lubricant: All O-Rings & seals must be lubricated with Bimba HT-99, or equivalent, with the exception of TSD400-71, which must remain dry.
ITEM | PART NUMBER | DESCRIPTION | QTY |
16 | TSD931-57 | Luer Lock Adaptor | 1 |
17 | 5320-000-001 | Outlet Block For TS5322 | 1 |
17* | 5320D-000-001 | Outlet Block For TS5322D | 1 |
18 | TSDI400-014A | 0-Ring, Buna | 1 |
19 | TSD931-75 | Luer Lock Adaptor, Elbow | 1 |
20 | TSD1120-6 | Retaining Ring, Medium | 1 |
21 | TSD1109-52 | Flat Washer | 1 |
22 | TSD400-71 | U-Cup Seal | 2 |
23 | 5320-000-002 | Body For TS5322 | 1 |
23* | 5320D-000-002 | Body For TS5322D | 1 |
24 | TD1103-349 | Outlet Block Screw | 4 |
TSD700-9 | Oiler Cup, Not Shown | 1 |
REPAIR KITS
ITEM | PART NUMBER | DESCRIPTION | QTY |
1 | TSD1400-208A | Piston 0-Ring, Buna | 1 |
2 | TSD1400-017A | End Cap, 0-Ring, Buna | 1 |
3 | TSD1400-014A | 0-Ring, Buna | 1 |
4 | TSD1400-013A | 0-Ring, Buna | 1 |
5 | TD1400-006A | 0-Ring, Buna | 1 |
6 | TSD400-71 | U-Cup Seal | 2 |
7 | TSD1103-349 | Outlet Screw | 4 |
8 | 5322-000-001 | Spool/Piston Assembly | 1 |
9 | TSD1109-52 | Flat Washer | 1 |
10 | TSD1109-45 | Nylon Washer | 1 |
11 | TSD1106-36 | Mounting Screw | 1 |
12 | TSD1120-15 | Retaining Ring, Large | 1 |
13 | TSD1120-2 | Retaining Ring, Small | 1 |
14 | TSD1120-6 | Retaining Ring, Medium | 1 |
15 | TSD931-57 | Luer Lock Adaptor | 1 |
16 | TSD931-75 | Luer Lock Adaptor, Elbow | 1 |
*These kits are for both variations of Techcon Systems Miniature Spool Valve
STANDARD ACCESSORIES
PART NUMBER | DESCRIPTION |
TSD700-9 | Oiler Cup, 90 Degrees |
7305XCON | Cleaning Gel, 30cc Syringe |
10.1 OPTIONAL ACCESSORIES
PART NUMBER | DESCRIPTION |
TS918-46 | 4-Way Fluid Manifold |
TNOODKIT | Complete Dispensing Tip Kit |
9000-000-100 | Sample Tip Kit |
5,322- SIT | Seal Insertion Tool |
10.2 FLUID FITTINGS AND TUBING
PART NUMBER | DESCRIPTION |
TSD1003-16 | 1/8″ NPT to’ ” O.D. Tube, 90° Elbow |
TSD 1002-17 | 1/8″ NPT to %” O.D. Tube |
TSD1002-18 | 1/8″ NPT to W O.D. Tube |
TSD1002-38 | 1/4″ NPT to’/” O.D. Tube |
TSD1099-22 | 3/8 ” O.D. X 1/4″ I.D. Tube, Black, Polyethylene |
TSD1099-23 | 3/8″ O.D. X 1/4″ I.D. Tube, Clear, Polyethylene |
TSD1099-24 | 1/4″ O.D. X 1/4″ I.D. Tube, Clear, Polyethylene |
TSD1099-25 | 1/4″ O.D. X 1/4″ I.D. Tube, Black, Polyethylene |
TSD1099-45 | 6mm O.D. X 4mm I.D, Clear, Polyethylene |
TSD1099-46 | 6mm O.D. X 4mm I.D, Black, Polyethylene |
TSD126-360BPK | Luer Lock Tubing, 60″ (1524mm) , Black |
TROUBLESHOOTING
PROBLEM | POSSIBLE CAUSE | CORRECTION |
No fluid flow | Fluid pressure too low | Increase fluid pressure |
Operating pressure too low | Increase air pressure to 70 psi (4.8bar) | |
Dispense tip clogged or damaged | Replace tip | |
Fluid cured in valve chamber | Clean valve thoroughly | |
Inconsistent fluid flow | Fluid pressure fluctuating | Make sure fluid pressure is constant |
Valve operating pressure is too low | Increased valve pressure to 70 psi (4.8bar) | |
Valve open time is not consistent | Check to make sure the valve controller is providing a consistent output | |
Air trapped in fluid housing | Purge valve | |
Fluid drools after the valve closes, eventually stopping | Air trapped in fluid housing | Purge valve |
Steady drip | Lower seal damaged or worn | Replace lower seal |
Spool damaged | Replace spool | |
Inlet air fitting is too long. pushing the spool opened | Replace air fitting | |
Valve re-assembled incorrectly | Re-assemble valve, follow reR assembly instructions |
LIMITED WARRANTY
Manufacturer warrants this product to the original purchaser for a period of one (1) year from date of purchase to be free from defects in material and workmanship, but not against damages by misuse, negligence, accident, faulty installations and instructions. Manufacturer will repair or replace (at factory’s option), free of charge, any component of the equipment thus found to be defective, on return of the component, “PREPAID” to the factory during the warranty period. In no event shall any liability or obligation of the Manufacturer arising from this warranty exceed the purchase price of the equipment. This warranty is only valid if the defective product is returned as a complete assembly without physical damage. The Manufacturer’s liability, as stated herein, cannot be altered or enlarged except by a written statement signed by an officer of the company. In no event shall the Manufacturer be liable for consequential or incidental damages. A return authorization is required from Techcon Systems prior to shipping a defective unit to the factory.
Manufacturer reserves the right to make engineering product modifications without notice.
All returns must be issued with a Returns Authorization number, prior to return.
Send warranty returns to:
Americas and Asia
OK International
12151 Monarch Street
Garden Grove, Ca 92841
Europe
OK International
Eagle Close
Chandler’s Ford Ind Est
Eastleigh
Hampshire
SO53 4NF
United Kingdom
Teflon® is a registered trademark of E.I. DuPont.
Documents / Resources
![]() |