TE connectivity VB Series General Purpose RFI Filters User Guide

VB Series General Purpose RFI Filters

Specifications:

  • Product Name: B Series RFI Power Line Filters
  • Application: General Purpose RFI Filters for High Impedance
    Loads at Low Current
  • Certifications: UL Recognized, CSA Certified, VDE Approved

Product Usage Instructions:

1. Application:

The B Series RFI Power Line Filters are designed for use with
portable equipment and non-patient medical equipment.

2. Installation:

Ensure that the power source is disconnected before installing
the filter. Connect the filter in-line with the power supply cable
of the equipment, following the manufacturer’s guidelines.

3. Maintenance:

Regularly inspect the filter for any signs of damage or wear.
Replace the filter if any issues are detected to maintain optimal
performance.

4. Troubleshooting:

If you experience any interference or noise issues with your
equipment, check the filter connections and ensure they are secure.
Contact customer support if problems persist.

FAQ:

Q: Can the B Series RFI Power Line Filters be used with
high-power equipment?

A: The filters are designed for high impedance loads at low
current. It is recommended to check the product specifications and
consult with the manufacturer for compatibility with high-power
equipment.

Q: How do I know if the filter needs replacement?

A: If you notice a decrease in filter performance, such as
increased interference or noise, or physical damage to the filter,
it may be time for a replacement. Regular maintenance checks are
advised to ensure optimal functionality.

B Series

Corcom Product Guide

Catalog: 1654001 Issue Date: 06.2011

General Purpose RFI Filters for High Impedance Loads at Low Current

UL Recognized CSA Certified VDE Approved

VB6

1

RFI Power Line Filters

B Series
· Small size & low cost · General purpose · Wide variety of termination options · Meets low leakage current requirements of VDE
portable equipment and non-patient medical equipment
Ordering Information 10 E B 1
Input / Output Style 1 ­ .250 [6.3] spade terminals 3 ­ Wire leads 6 ­ Threaded bolt
B Series
Leakage current designation E ­ Low leakage (<0.5 mA) V ­ Standard
Current Rating 1, 2, 3, 5, 10, 20 or 30A

Electrical Schematic
LINE

LOAD

VB1 / EB1

VB3 / EB3

Specifications

Maximum leakage current each Line to Ground:

VB Models

EB Models

@ 120 VAC 60 Hz:

.4 mA

.21 mA

@250 VAC 50 Hz:

.7 mA

.36 mA

Hipot rating (one minute): Line to Ground: Line to Line:

2250 VDC 1450 VDC

Rated Voltage (max): Operating Frequency: Rated Current:

250 VAC 50/60 Hz
1 to 30A

Operating Ambient Temperature Range

(at rated current Ir):

-10°C to +40°C

In an ambient temperature (Ta) higher than +40°C

the maximum operating current (Io) is calculated as

follows: Io = Ir (85-Ta)/45

Available Part Numbers
1VB1 1VB3 2VB1 2VB3 3VB1 3VB3 5VB1 5VB3 10VB1 10VB3 10VB6 20VB1 20VB6 30VB6

1EB1 1EB3 2EB1 2EB3 3EB1 3EB3 5EB1 5EB3 10EB1 10EB3 20EB1

Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change.
Downloaded from Arrow.com.

15
For email, phone or live chat, please go to
te.com/help
corcom.com

B Series
Case Styles B1

Corcom Product Guide

Catalog: 1654001 Issue Date: 06.2011

General Purpose RFI Filters for High Impedance/ Low Current (continued)

30VB6

E DB

A

C

E DB

2.00 50.8

A

C

B3
Blue
E DB
Brown

Blue Green/Yellow
Brown

A

C

10VB6 & 20VB6
E DB

A

C

Case Dimensions

Part No.

A

B

1VB1, 1EB1, 2VB1, 2EB1

1VB3, 1EB3,

2VB3, 2EB3

3VB1, 3EB1,

5VB1, 5EB1

3VB3, 3EB3, 5VB3, 5EB3

10VB1, 10EB1

10VB3, 10EB3

10VB6

20VB1, 20EB1

20VB6

30VB6

C

D

E

16
Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change.
Downloaded from Arrow.com.

For email, phone or live chat, please go to te.com/help corcom.com

Corcom Product Guide

Catalog: 1654001 Issue Date: 06.2011

General Purpose RFI Filters for High Impedance/ Low Current (continued)

B Series

Performance Data

Typical Insertion Loss
Measured in closed 50 Ohm system

1EB & 3EB

db 100 90 80 70 60 50 40 30 20

10

0

0.1

1

10

30

Frequency in MHz

Common Mode / Asymmetrical (L-G) Differential Mode / Symmetrical (L-L)

2EB, 5EB & 10EB

db 100 90 80 70 60 50 40 30

20 10 0
0.1

1

10

30

Frequency in MHz

20EB

db 100

90

80

70

60

50

40

30

20

10

0

0.1

1

10

30

Frequency in MHz

1VB
db 100 90 80 70 60 50 40 30 20
10 0
0.1

1

10

30

Frequency in MHz

2VB
db 100 90 80 70 60 50 40 30 20
10 0
0.1

1

10

30

Frequency in MHz

3VB
db 100 90 80 70 60 50 40 30 20
10 0
0.1

1

10

30

Frequency in MHz

10VB

db 100

90

80

70

60

50

40

30

20

10

0

0.1

1

10

30

Frequency in MHz

20VB

db 100

90

80

70

60

50

40

30

20

10

0

0.1

1

Minimum Insertion Loss
Measured in closed 50 Ohm system

Common Mode / Asymmetrical (Line to Ground)

10

30

Frequency in MHz

Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change.
Downloaded from Arrow.com.

30VB

db 100

90

80

70

60

50

40

30

20

10

0

0.1

1

10

30

Frequency in MHz

17
For email, phone or live chat, please go to
te.com/help
corcom.com

RFI Power Line Filters

1

Documents / Resources

TE connectivity VB Series General Purpose RFI Filters [pdf] User Guide
VB6, VB Series General Purpose RFI Filters, VB Series, General Purpose RFI Filters, Purpose RFI Filters, RFI Filters, Filters

References

Leave a comment

Your email address will not be published. Required fields are marked *