TE Connectivity T Series Single Phase Filters

Product Information
Specifications
- Product Name: T Series Corcom Power Line Filters
- Model: T Series
- Catalogue Number: 1654001
- Issue Date: 06.2011
- Application: High-Performance RFI Power Line Filters for Switching Power Supplies
- Certifications: UL Recognised, CSA Certified, VDE Approved
Product Usage Instructions
Installation
- Ensure that the power supply is turned off and unplugged.
- Identify the load side of the power supply where the filter will be installed.
- Mount the T Series Corcom Power Line Filter securely in place using appropriate hardware.
- Connect the input and output terminals of the filter to the corresponding terminals on the power supply.
- Double-check all connections before turning the power supply back on.
Maintenance
- Regularly inspect the T Series Corcom Power Line Filter for any signs of damage or wear. Clean the filter if necessary to ensure optimal performance.
Disposal
- When disposing of the filter, follow local regulations for electronic waste disposal to minimise environmental impact.
Troubleshooting
- If you experience any issues with the filter, refer to the user manual for troubleshooting steps or contact customer support for assistance.
T Series
- Superior common-mode and premium differential-mode attenuation
- Smaller package sizes than the EP Series
- Size and cost-effective
- ET models can help meet very low leakage current requirements
Ordering Information

IEC 60320-1 C14 inlet mates with C13 connector
Specifications
Maximum leakage current each Line to Ground:
3, 6 & 10A ET Models VT Models
- @120 VAC 60 Hz: .30 mA .75 mA
- @250 VAC 50 Hz: .50 mA 1.2 mA
15 & 20A
- @120 VAC 60 Hz: .30 mA 1.2 mA
- @250 VAC 50 Hz: .50 mA 2.0 mA
Hipot rating (one minute):
- Line to Ground: 2250 VDC
- Line to Line: 1450 VDC
- Rated Voltage (max): 250 VAC
- Operating Frequency: 50/60 Hz
- Rated Current: 3 to 20A
Operating Ambient Temperature Range
Available Part Numbers
| 3ET1 | 10ET1 | 10VT1 |
| 3ET3 | 10ET3 | 10VT3 |
| 3ET7 | 15ET1 | 15VT1 |
| 6ET1 | 15ET6 | 15VT6 |
| 6ET3 | 20ET1 | 20VT1 |
| 6ET7 | 20ET6 | 20VT6 |
Electrical Schematics
3 & 6A
10A
15 & 20A
Accessories
GA400: NEMA 5-15P to IEC 60320-1 C-13 line cord
Case Styles
T1 (3, 6, 10A)
Typical Dimensions:
- Line/Load Terminals (4): 250 [6.3] with .07 [1.8] Dia. hole
- Ground Terminal (1): 250 [6.3] with .07 x .16 [1.8 x 3.8] slot
- Mounting Holes (2): .188 (4.78) Dia.
T1 (15 & 20A)
Typical Dimensions:
- Line/Load Terminals (4): 250 [6.3] with .07 [1.8] Dia. hole
- Ground Terminal (1): 250 [6.3] with .07 x .16 [1.8 x 3.8] slot
- Mounting Slots (4): 250 x. 156 [6.35 x 3.96] Dia.
T3
Typical Dimensions:
- Wire Leads (5): 4.0 [101.6] Min., AWG18
- Mounting Holes (2): 188[4.78] Dia.
T6
Typical Dimensions:
- Terminals (5): 8-32, Torque 18 Ibf-in. [2.03 N-m] max. $ 2 [.22]
- Mounting Slots (4): 250 x 156 [6.35 x 3.96] Dia.
T7
Typical Dimensions:
- Terminal (2): .250 [6.3] with .07 [1.8] Dia. hole
- Ground Terminal (1): 250 [6.3] with .07 x .16 [1.8 x 3.8] slot
- Line Inlet (1): IEC 60320-1 C14
- Tapped Inserts (2): 6-32 x 1/4
Recommended Panel Cutout

Tolerance # .005 [0.13]
Case Dimensions

Performance Data
Typical Insertion Loss
- Common Mode / Asymmetrical (L-G)
- Differential Mode / Symmetrical (L-L)
Measured in a closed 50 Ohm system
Minimum Insertion Loss
Measured in a closed 50 Ohm system
- Dimensions are in inches and millimetres unless otherwise specified. Values in italics are metric equivalents.
- Dimensions are shown for reference purposes only.
- Specifications subject to change.
CUSTOMER SERVICE
- For email, phone or live chat, please go to te.com/help
- corcom.com
- Downloaded from Arrow.com.
Frequently Asked Questions
How do I know which model of the T Series Corcom Power Line Filter to choose?
Refer to the specifications in the user manual or consult with a technical expert to determine the appropriate model based on your power supply requirements.
Can I use the T Series filter with any power supply?
The T Series Corcom Power Line Filter is designed for use with switching power supplies. Ensure compatibility before installation.
Is professional installation required for the T Series filter?
While professional installation is recommended for optimal performance, users with technical knowledge can install the filter following the provided instructions.
Documents / Resources
![]() |
TE Connectivity T Series Single Phase Filters [pdf] User Guide 6609046-4, 66090464, T Series Single Phase Filters, T Series, Single Phase Filters, Phase Filters, Filters |