TE-Connectivity-logo

TE Connectivity SRBP Series Corcom Shielded Power Inlet Filter

TE-Connectivity-SRBP-Series-Corcom-Shielded-Power-Inlet-Filter-product

Specifications

  • UL Recognized, CSA Certified, VDE Approved
  • Operating Frequency: 50/60 Hz
  • Rated Voltage: 250 VAC
  • Rated Current: 15A
  • Capacitor Options: Q, R, S, T, W, X, Y, Z
  • Hipot Rating: 2250 VDC Line to Ground, 1450 VDC Line to Line

Product Usage Instructions

Installation

  1. Ensure power is disconnected before installation.
  2. Mount the SRB Series filter securely in the desired location.
  3. Connect the input power lines to the designated terminals following proper polarity.
  4. Ground the filter according to local electrical codes.

Maintenance
Regularly inspect the filter for any signs of damage or wear. Replace if necessary to maintain optimal performance.

SRB Series

  • Smallest depth Corcom RFI filter available
  • Complete shield
  • Wide range of capacitor values
  • Attenuates coupled EMI up to 300MHz
  • Minimal to low leakage current versions are suitable for patient and non-patient contact medical equipment.
  • Full range of mounting and termination options including unique vertical and horizontal orientation slide in mounts, eliminates the need for mounting hardware

Ordering Information

TE-Connectivity-SRBP-Series-Corcom-Shielded-Power-Inlet-Filter-fig-1

  • 15A versions are tested by Underwriters Laboratories to US and Canadian requirements and are VDE approved at 10A, 250VAC

Specifications

Maximum leakage current each Line to Ground

TE-Connectivity-SRBP-Series-Corcom-Shielded-Power-Inlet-Filter-fig-18

Hipot rating (one minute)

  • Line to Ground: 2250 VDC
  • Line to Line: 1450 VDC
  • Rated Voltage (max.): 250 VAC
  • Operating Frequency: 50/60 Hz
  • Rated Current: 15A*

Operating Ambient Temperature Range (at rated current Ir)

TE-Connectivity-SRBP-Series-Corcom-Shielded-Power-Inlet-Filter-fig-19

Capacitor Options

Capacitor ID Capacitor Value
Q 33 pF
R 100 pF
S 220 pF
T 330 pF
W 470 pF
X 1000 pF
Y* 2200 pF
Z* 3300 pF

Available Part Numbers

Flange Mount

15SRB1 15SRB2 15SRBP 15SRB8
15SRB1-Q 15SRB2-Q 15SRBP-Q 15SRB8-Q
15SRB1-R 15SRB2-R 15SRBP-R 15SRB8-R
15SRB1-S 15SRB2-S 15SRBP-S 15SRB8-S
15SRB1-T 15SRB2-T 15SRBP-T 15SRB8-T
15SRB1-W 15SRB2-W 15SRBP-W 15SRB8-W
15SRB1-X 15SRB2-X 15SRBP-X 15SRB8-X
15SRB1-Y 15SRB2-Y 15SRBP-Y  
15SRB1-Z 15SRB2-Z 15SRBP-Z  
Snap-In Slide-In
15SRBS1 15SRBS8 15SRBX8 15SRBY8
15SRBS1-Q 15SRBS8-Q 15SRBX8-Q 15SRBY8-Q
15SRBS1-R 15SRBS8-R 15SRBX8-R 15SRBY8-R
15SRBS1-S 15SRBS8-S 15SRBX8-S 15SRBY8-S
15SRBS1-T 15SRBS8-T 15SRBX8-T 15SRBY8-T
15SRBS1-W 15SRBS8-W 15SRBX8-W 15SRBY8-W
15SRBS1-X 15SRBS8-X 15SRBX8-X 15SRBY8-X
15SRBS1-Y      
15SRBS1-Z      

Electrical Schematic

TE-Connectivity-SRBP-Series-Corcom-Shielded-Power-Inlet-Filter-fig-2

Accessories

  • GA400: NEMA 5-15P to IEC 60320-1 C-13 line cordTE-Connectivity-SRBP-Series-Corcom-Shielded-Power-Inlet-Filter-fig-20

Case Styles

SRB1

TE-Connectivity-SRBP-Series-Corcom-Shielded-Power-Inlet-Filter-fig-3

Typical Dimensions:

  • Mounting holes (2):
    • 132 [3.35] Dia. with .236 [5.99] Dia. x 90° countersink for #4 flathead screw
  • Line Inlet (1):
    • IEC 60320-1 C14
  • Load Terminals (2):
    • 250 [6.3) with .07 [1.8] Dia. hole
  • Ground Terminal (1):
    • 250 [6.3] with .07 x .16 [1.8 x 3.8] slot

SRB2

TE-Connectivity-SRBP-Series-Corcom-Shielded-Power-Inlet-Filter-fig-4

Typical Dimensions

  • Mounting holes (2):
    • 132 [3.35] Dia. with .236 [5.99] Dia. x 90° countersink for #4 flathead screw
  • Line Inlet (1):
    • IEC 60320-1 C14
  • Load Terminals (2):
    • 250 [6.3] with .07 [1.8] Dia. hole
  • Ground Terminal (1):
    • 250 [6.3] with .07 x .16 [1.8 x 3.8] slot

SRBP

TE-Connectivity-SRBP-Series-Corcom-Shielded-Power-Inlet-Filter-fig-5

Typical Dimensions
  • Mounting holes (2)
    • IEC 60320-1 C14
  • Line Inlet (1)
    • 250 [6.3] with .07 [1.8] Dia. hole
  • PC board pins (3)
    • 250 [6.3] with .07 x .16 [1.8 x 3.8] slot

SRB8

TE-Connectivity-SRBP-Series-Corcom-Shielded-Power-Inlet-Filter-fig-7

Typical Dimensions

  • Mounting holes (2): 132 [3.35] Dia. with .236 [5.99] Dia. x 90° countersink for #4 flathead screw
  • Line Inlet (1): IEC 60320-1 C14
  • Wire Leads: 4.0 [101.6] Min., 18AWG, UL1015

SRBS8

TE-Connectivity-SRBP-Series-Corcom-Shielded-Power-Inlet-Filter-fig-8

Typical Dimensions

  • Line Inlet (1):
    • IEC 60320-1 C14
  • Wire Leads:
    • 4.0 [101.6] Min., 18AWG, UL1015

SRBY8

TE-Connectivity-SRBP-Series-Corcom-Shielded-Power-Inlet-Filter-fig-9

Typical Dimensions

  • Line Inlet (1):
    • IEC 60320-1 C14
  • Wire Leads:
    • 4.0 [101.6] Min., 18AWG, UL1015

Case Dimensions

TE-Connectivity-SRBP-Series-Corcom-Shielded-Power-Inlet-Filter-fig-21

Recommended Panel Cutouts

SRB1, SRB2, SRBP & SRB8

TE-Connectivity-SRBP-Series-Corcom-Shielded-Power-Inlet-Filter-fig-10

SRBS

TE-Connectivity-SRBP-Series-Corcom-Shielded-Power-Inlet-Filter-fig-11

SRBX

TE-Connectivity-SRBP-Series-Corcom-Shielded-Power-Inlet-Filter-fig-12

SRBY

TE-Connectivity-SRBP-Series-Corcom-Shielded-Power-Inlet-Filter-fig-13

PC Board Layout

TE-Connectivity-SRBP-Series-Corcom-Shielded-Power-Inlet-Filter-fig-14 TE-Connectivity-SRBP-Series-Corcom-Shielded-Power-Inlet-Filter-fig-15

Performance Data

Typical Insertion Loss
Measured in a closed 50 Ohm system

TE-Connectivity-SRBP-Series-Corcom-Shielded-Power-Inlet-Filter-fig-16

Minimum Insertion Loss
Common Mode / Asymmetrical (Line to Ground)
Measured in closed 50 Ohm system

TE-Connectivity-SRBP-Series-Corcom-Shielded-Power-Inlet-Filter-fig-17

Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change.For email, phone or live chat, please go to te.com/help corcom.com

FAQs

What is the maximum leakage current for each Line to Ground at different voltages?

@120 VAC: 2.1 A, @250 VAC: 3.65 A

What are the available capacitor options for the SRB Series?

Q (33 pF), R (100 pF), S (220 pF), T (330 pF), W (470 pF), X (1000 pF), Y (2200 pF), Z (3300 pF)

How should I calculate the maximum operating current for the SRB Series?

Io = Ir (85-Ta)/45, where Io is the maximum operating current, Ir is the rated current, and Ta is the ambient temperature.

Documents / Resources

TE Connectivity SRBP Series Corcom Shielded Power Inlet Filter [pdf] User Guide
SRBP, SRBS8, SRB1, SRB2, SRBP Series Corcom Shielded Power Inlet Filter, SRBP Series, Corcom Shielded Power Inlet Filter, Shielded Power Inlet Filter, Power Inlet Filter, Inlet Filter, Filter

References

Leave a comment

Your email address will not be published. Required fields are marked *