TBO-ELECTRONICS-logo

TBO ELECTRONICS TRA3 Power Relay

TBO-ELECTRONICS-TRA3-Power-Relay-product-image

Product Usage Instructions

Coil Data
The relay coil has various rated voltages and currents for different operating conditions:

Rated Voltage (VDC) Rated Current (mA) Max. Operate Voltage (VDC) Min. Release Voltage (VDC)

Safety Approved Ratings
The safety approved ratings include various parameters like coiling rating, contact rating, and more.

Ordering Information
To order the correct relay, refer to the following information:

  • Type: TRA3
  • Coil Power: D(0.72W) L(0.54W) M(0.24W)
  • Coil Voltage: Various options from 03VDC to 48VDC
  • Construction: Plastic sealed or flux proofed
  • Contact Arrangement: Special Code (2H, 2Z, 2D)

POWER RELAY

  • Creepage distance:8.0mm Min
  • Au-clad contact available
  • Transparent sealed available
  • Class B/F available
  • Conform to RoHS,ELV directive

CONTACT DATA

Contact Arrangement 2H/2Z
Contact Material Silver Alloy
Load Resistive load (cosФ=1)
Contact Ratings 5A240VAC

5A 30VDC

Min. Contact Load 100mA 5VDC
Max. Switching Voltage 250VAC/30VDC
Max. Switching Current 8A
Max. Switching Power 1250VA/240W
Contact Resistance ≤100mΩ (6VDC 1A)
Electrical Endurance 1×105 OPS(at 6 OPS/min)  1×105 ( 6)
Mechanical Endurance 5×106 OPS(at 300 OPS/min)  5×106次( 300)

CHARACTERISTICS

Insulation Resistance 100MΩ Min. at 500VDC
 Dielectric Strength Between Open Contacts 1000VAC (50/60Hz 1 min)
Between Contacts and Coil 5000VAC (50/60Hz 1 min)
Operate Time ≤20ms
Release Time ≤10ms
Ambient Temperature -40℃to+85℃
Shock Resistance Functional : 10G
Destructive : 100G
Vibration Resistance 10~55Hz, 1.5mm DA
Humidity 40~85%
Unit Weight Approx. 14g 14

COIL DATA  (at 23℃)

Rated Voltage  (VDC) 3 5 6 9 12 24 48 0.24W
Coil Resistance (Ω±10%) 38 104 150 338 600 2400 9600
Rated Current  (mA) 80 48 40 26.7 20 10 5
Max. Operate Voltage  (VDC) 2.4 4 4.8 7.2 9.6 19.2 38.4
Min. Release Voltage  (VDC) 0.15 0.25 0.3 0.45 0.6 1.2 2.4
Coil Resistance  (Ω±10%) 17 46 67 150 270 1050 4250 0.54W
Rated Current  (mA) 180 108 90 60 45 22.5 11.3
Max. Operate Voltage  (VDC) 2.4 4 4.8 7.2 9.6 19.2 38.4
Min. Release Voltage  (VDC) 0.15 0.25 0.3 0.45 0.6 1.2 2.4
Coil Resistance (Ω±10%) 13 35 50 110 200 800 3200 0.72W
Rated Current  (mA) 240 144 120 80 60 30 15
Max. Operate Voltage  (VDC) 2.4 4 4.8 7.2 9.6 19.2 38.4
Min. Release Voltage  (VDC) 0.15 0.25 0.3 0.45 0.6 1.2 2.4
Max. Voltage 3.9 6.5 7.8 11.7 15.6 31.2 62.4

Remark: Max. Voltage refers to the maximum voltage which relay coil could endure in a period of time.

SAFETY APPROVED RATINGS 

Model Coiling rating Safety Standard Contact rating
TRA3  3 to 48VDC TÜV 5A 240VAC

5A 30VDC

UL/cUL 5A 240VAC

5A 30VDC

CQC 5A 240VAC

ORDERING INFORMATION TBO-ELECTRONICS-TRA3-Power-Relay-image (1)

CHARACTERISTIC CURVES

TBO-ELECTRONICS-TRA3-Power-Relay-image (2) TBO-ELECTRONICS-TRA3-Power-Relay-image (3)

DIMENSIONS

OUTLINE DIMENSIONS, WIRING DIAGRAM AND PC BOARD LAYOUT 

OUTLINE DIMENSIONS
TBO-ELECTRONICS-TRA3-Power-Relay-image (4)

PC BOARD LAYOUT
TBO-ELECTRONICS-TRA3-Power-Relay-image (5)

WIRING DIAGRAM

TBO-ELECTRONICS-TRA3-Power-Relay-image (6)

Remark

  1. In case of no tolerance shown in outline dimension: outline dimension ≤1mm, tolerance should be ±0.2mm; outline dimension >1mm and ≤5mm, tolerance should be ±0.3mm; outline dimension >5mm, tolerance should be ±0.4mm.
  2. The additional tin top is max. 1mm.
  3. The tolerance without indicating for PCB layout is always ±0.1mm.

Disclaimer
The specification is for reference only. Specification subject to change without notice.

FAQs

What is the maximum switching power of the relay?

The relay has a maximum switching power of 600W.

What is the electrical endurance of the relay?

The relay has electrical endurance specifications provided in the manual.

Can the relay operate in high humidity environments?

The relay can operate in humidity levels ranging from 40% to 85%.

How do I select the appropriate coil voltage for my application?

Refer to the ordering information section in the manual for guidance on selecting the correct coil voltage.

Is the relay compliant with RoHS and ELV directives?

Yes, the relay conforms to RoHS and ELV directives as stated in the manual.

What is the creepage distance of the relay?

The creepage distance of the relay is specified as 8.0mm minimum.

Documents / Resources

TBO ELECTRONICS TRA3 Power Relay [pdf] User Guide
TRA3, TRA3 Power Relay, TRA3, Power Relay, Relay

References

Leave a comment

Your email address will not be published. Required fields are marked *