sensor switch Manuals & User Guides

User manuals, setup guides, troubleshooting help, and repair information for sensor switch products.

Tip: include the full model number printed on your sensor switch label for the best match.

sensor switch manuals

Latest posts, featured manuals, and retailer-linked manuals for this brand tag.

legrand RW600B Vacancy Sensor Switch Instruction Manual

January 4, 2024
legrand RW600B Vacancy Sensor Switch Product Information Specifications Voltage: 120VAC, 60Hz Load (Single Pole Circuit) Coverage Range: 180 degrees Coverage Area: 600 square feet (56 square meters) Description and Operation The RW600B Vacancy Sensor is designed to replace a standard…

Enerlites HMOS 180 Degree Occ and Vac Motion Sensor Switch Installation Guide

November 15, 2023
Enerlites HMOS 180 Degree Occ and Vac Motion Sensor Switch Installation Guide SPECIFICATIONS Voltage..............................................................................120VAC,60Hz Resistive.............................................................................................5A Incandescent..............................................................................500W Electronic Ballast..........................................................800VA@120VAC Motor.............................................................................................1/8Hp Time Delay.........................................................15Sec, 10Mins, 20Mins Default Light Level..........................................................30 Lux--Daylight Operation Temperature.....................................................32° F--131° F DESCRIPTION The HMOS uses advanced passive infrared sensor to…

Enerlites DWTOS Series Air Circulator w 180° PIR Motion Sensor Switch Instruction Manual

November 14, 2023
INSTALLATION INSTRUCTIONS DWTOS PIR Occupancy Sensor and Air Circulator SPECIFICATIONS Voltage............................................................................................120VAC, 60Hz Electronic Ballast/LED.......................................................................400VA/400W Resistive/Tungsten..................................................................................3A/500W Light Time Delay.................................................Test mode 15s, 5 to 30 minutes PIR Coverage............................................................................................600sq.ft Maximum Fan Load..................................................................1/4th hp or 3 Amps Fan Time Delay..............................................................................5 to 60 minutes Minutes…