Philips PI-50 Emergency Inverter

Leading the way in innovative design and greater ease of installation

Product Overview

The Philips PI-50 is an emergency inverter designed for luminaires where the installation of a standard emergency driver is impractical. Its slim form factor (21.90" x 3.58" x 1.32") and simple wiring facilitate easy installation. The PI-50 features sinusoidal output voltage and automatic dimming of luminaires up to 300 W, ensuring exceptional compatibility and flexibility. It works with non-dimmable luminaires up to 50 VA or 0-10V dimmable luminaires up to 300 W to create an emergency lighting system when a standard emergency driver is not suitable.

Dimming Application & Ease of Installation

The PI-50 offers automatic 0-10V dimming control. This patented dimming capability allows a lighting load with up to a 300 W maximum input power to be dimmed to a 50 VA maximum emergency output power. The emergency mode output dimming voltage is automatically controlled by the PI-50 electronic circuitry to maintain up to 50 VA output during AC power loss. During normal operation (AC mains on), the PI-50 passes through the normal room switched AC mains and dimming controls, so the fixture's normal dimming operation is unaffected.

Key Benefits

Dimensions

Dimensions: 21.90" x 3.58" x 1.32" (556 mm x 91 mm x 33.5 mm)

Mounting center: 21.50" (546 mm)

Flexible Conduit: 24" length; 3/8" Trade Size

Wiring Schematic

The wiring schematic illustrates the connections for the PI-50 inverter, including inputs for DIM+ IN, DIM- IN, NEUTRAL IN, Unswitched HOT, and Switched HOT IN. Outputs include DIM+ OUT, DIM- OUT, NEUTRAL OUT, and HOT OUT, connecting to a DRIVER OR BALLAST and ultimately the LIGHT SOURCE. Earth Ground is also indicated.

Relevant Part Numbers

Part Number 12 NC Number Description
PI50J1UK50C1ADI1 913702494301 Metal housing with conduit
PMBP12550 913702494401 Optional Mounting Bracket

Specifications

UL Listed for US and Canada: Listed to UL924 and tested to CSA 22.2, No. 141. For Field or Factory Installation (Indoor and Damp)

Maximum Connected Load: 300 W (0-10V dimmable) / 50 VA (non-dimmable)

Maximum Output Power: 50 VA into load

Illumination Time: 90 Minutes

AC Input Voltage and Current: 120 through 277VAC, 50/60 Hz, 100 mA (charging)

Surge Withstand: 4 kV (ANSI C82.77-5)

Recharge Time: 36 Hours

Charging Indicator Light / Test Switch: Bi-color Plenum Rated Integrated LED Test Switch

Battery: Maintenance-Free Li-ion Battery

Output Voltage, Emergency: 120 VAC ± 10%

Output Frequency: 60 Hz, ± 5%

Dimming: 0-10V

Transfer Time: Approximately 2 to 5 seconds

Temperature Rating (Ambient): 32 to 122°F (0-50°C)

Temperature Rating (Tcase): Case Tc (max): 65°C

Dimensions: 21.90" x 3.58" x 1.32" (556 mm x 91 mm x 33.5 mm), Mounting center 21.5" (546 mm)

Weight: 6.0 lbs. (2.72kg)

Warranty: 5 years (NOT pro-rata)

Compatible TLEDs

The PI-50 is compatible with all Philips TLED Mains Fit (Type B) lamps, regardless of style and dimming type, provided the total lamp load remains under the inverter's Maximum Output Power rating (non-dimming).

Compatible Luminaires

The PI-50 is compatible with many Lightolier 3D Printed luminaires, including the IHB, PM, and BAL Series. It is recommended to check the specific luminaire power rating to confirm compatibility for your application.

For more information, please visit www.philips.com/ledlamps or www.3dprinted.lighting.lightolier.com/en/us/.

© 2024 Signify Holding. All rights reserved. The information provided herein is subject to change, without notice. Signify does not give any representation or warranty as to the accuracy or completeness of the information included herein and shall not be liable for any action in reliance thereon. The information presented in this document is not intended as any commercial offer and does not form part of any quotation or contract, unless otherwise agreed by Signify.

Signify North America Corp. 400 Crossing Boulevard, Bridgewater, NJ 08807 Telephone 800-555-0050

Signify Canada Ltd. 281 Hillmount Road, Markham, ON, Canada L6C 2S3 Telephone 800-668-9008

Philips and the Philips Shield Emblem are registered trademarks of Koninklijke Philips N.V. All other trademarks are owned by Signify Holding or their respective owners.

Models: PI-50, PI-50 Emergency Inverter, Emergency Inverter, Inverter

File Info : application/pdf, 3 Pages, 2.23MB

PDF preview unavailable. Download the PDF instead.

IHB-Series-Emergency-Large

References

Adobe PDF Library 17.0 Adobe InDesign 20.0 (Windows)

Related Documents

Preview Philips PI-25 Emergency Inverter: Auto-Dimming 25 VA Sinusoidal Output
Explore the Philips PI-25 Emergency Inverter, a slim, auto-dimming 25 VA unit designed for effortless installation with luminaires up to 200W. Key features include 0-10V dimming, self-testing, and broad compatibility with LED and fluorescent fixtures.
Preview Philips PTB15D: 15W Phase-Cut Dimmable Emergency Inverter for Type B TLED
Discover the Philips PTB15D, a slim, phase-cut dimmable emergency inverter designed for Type B TLED fixtures. It offers enhanced installation flexibility and compatibility where standard drivers fail, meeting California Title 20 efficiency requirements.
Preview Philips GreenUp Round Highbay Luminaire - Technical Specifications and Features
Detailed information on the Philips GreenUp Round Highbay luminaire, including its benefits, features, technical specifications, and available versions. This product offers excellent energy savings, high light quality, and long-term reliability for industrial applications.
Preview Philips HF-Regulator II for TL-D Fluorescent Lamps - HF-R 158 TL-D EII 220-240V 50/60Hz
Technical specifications and product details for the Philips HF-Regulator II HF-R 158 TL-D EII, a high-frequency electronic ballast for TL-D fluorescent lamps with 1-10V analog dimming protocol.
Preview Philips EasySense SNS412 IA Wireless Node Quick Installation Guide
Quick installation guide for the Philips EasySense SNS412 IA wireless node, detailing electrical specifications, environmental conditions, FCC/IC statements, wiring diagrams, and mounting dimensions for fixture integration.
Preview Philips Maxos Fusion LL500X/LL600X LED Luminaires: Technical Specifications and Installation Guide
Comprehensive technical specifications, installation guidance, and product details for Philips Maxos Fusion LL500X and LL600X LED lighting systems, covering general specifications, emergency lighting, wiring, and system IP ratings.
Preview Philips Lighting Catalogue 2015/16: Professional and Consumer Lighting Solutions
Explore the comprehensive Philips Lighting Catalogue 2015/16, featuring a wide range of professional and consumer luminaires, lamps, and lighting control systems. Discover energy-efficient LED solutions, innovative designs, and detailed product specifications for all your lighting needs.
Preview Philips Green Perform Highbay Elite BY718P LED100/NW - High-Performance Industrial Luminaire
Discover the Philips Green Perform Highbay Elite BY718P LED100/NW, a high-performance LED luminaire designed for industrial and high-ceiling applications. Featuring an award-winning finless design, excellent light quality, energy savings, and connectivity options with Interact Pro.