SYSIOT logoUHF RFID INTEGRATED READERSYSIOT SR RU1XG09B03 UHF Rfid Integrated ReaderOwner’s Manual
Model: SR-RU1XG09B03(M290290) Series

Application:

It can be widely used in logistics tracking, commodity inventory, cargo sorting, vehicle management, personnel management, asset management, medical systems, cold chain management, temperature monitoring, power monitoring, anti-counterfeiting systems and production process control and many other applications.

Features

  • Full series of products developed with independent intellectual property rights.
  • Full series of modules based on UHF chip development, with the ability to provide personalized product support.
  • The whole series of products are modularized to meet the combination of product functions required by the project, while reducing product cost and production efficiency.
  • The whole series of products are supported by the same SDK regardless of product solution and product form, simplifying the development of multi-product applications for customer projects.
  • Modules and core control boards have rock-solid stability based on nearly 10 years of R&D and production iterations.
  • UHF reading TID/EPC various operation combinations, provide data format personalization.
  • Desktop card issuer supports keyboard mode, seamless switching in the industrial field.
  • Most products support network communication, simplifying wiring connection.
  • With European CE / U.S. FCC / Korea KC / Canada ID and other multi-regional product certification.
  • Provide multi-OS, such as Windows, Android, Linux, server, Raspberry Pi, cloud.
  • Provide multi-language, such as C++, C#, PYTHON, JAVA etc.
  • Provide multi-protocol, such as SysIoT standard protocol, TCP, HTTP, UDP, Wiegand (26/27/32/34),
  • Provide OS, language, protocol custom development and OEM&ODM services.

Reader Specifications

Parameter Model
SR-RU16G09B03
RF Antenna Frequency 902 ∼ 928MHz
RF Frequency 902 ∼ 928MHz (Can be customized)
Protocol ISO 18000-6C/6B
RSSI Support
Reading distance ≥20m
Reading speed ≥500/S
Reader Interface Standard: USB, RS232, RS485/Weigand, RJ45(TCP/IP, UDP
Baud rate 38400/59600/115200bps
Read value TID+EPC/USER
Mode Command, polling or trigger
Operating Voltage DC 12.0V (+9-24V)
Operating Current ≤800mA / DC12V
Standby Current  ≤200mA / DC12V
Operating Temperature -20∼55°C
Storage Temperature -40∼85°C
Operating Humidity <95%RH (+25°C)
Performance High performance
Support SDK Support
IAP firmware Update Support
Custom Development Support

Antenna Specification

Electrical Specifications Mechanical Specifications
Gain 9.52dBi Dimension 210*210*80mm
Polarization Circular Weight 2.2kg
Beam width (H/V) Hor:60±2°/ Ver:60±2° Reflector material Aluminum
VSWR ≤1.5 Radome material ABS+PA757
Impedance 500 Radome Color Black/White
F/B Ratio .≥25 IP Class IP65
Lightning Protection DC Ground Operating Temperature -20∼60°C
Storage Temperature -40∼85°C
Holding rod diameter q)40-50mm

FCC WARNING
This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
Any changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment.
NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications.
However, there is no guarantee that interference will not occur in a particular installation.
If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:

  • Reorient or relocate the receiving antenna.
  • Increase the separation between the equipment and receiver.
  • Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
  • Consult the dealer or an experienced radio/TV technician for help.

To maintain compliance with FCC’s RF Exposure guidelines, This equipment should be installed and operated with minimum distance between 20cm the radiator your body: Use only the supplied antenna.

SYSIOT logowww.sysiotrfid.com
sales@sysiotrfid.com

Documents / Resources

SYSIOT SR-RU1XG09B03 UHF Rfid Integrated Reader [pdf] Owner's Manual
SR-RU1XG09B03 UHF Rfid Integrated Reader, SR-RU1XG09B03, UHF Rfid Integrated Reader, Rfid Integrated Reader, Integrated Reader, Reader

References

Leave a comment

Your email address will not be published. Required fields are marked *