SYSGRATION-LOGO

SYSGRATION AIX-600 Qualcomm Edge AI Box

SYSGRATION-AIX-600-Qualcomm-Edge-AI-Box-PRODUCT

Specifications

  • Product: Edge AI Box
  • Edition: 1
  • Last Update: 29 September 2024
  • Copyright Notice
  • FCC Class A

Product Usage Instructions

Packing List

Before installing the AIX-600 Edge AI Box, ensure the following materials are included:

  • AIX-600 unit
  • Accessories for AIX-600

Technical Support and Assistance

For technical support or assistance:

  • Visit the Sysgration website at www.sysgration.com for the latest product information.
  • Contact your distributor, sales representative, or Sysgration’s customer service center with the following information ready:
    • Product name and serial number
    • Description of peripheral attachments
    • Description of software (operating system, version, application software, etc.)
    • Complete description of the problem
    • Exact wording of any error messages
  • Contact Information: Sysgration Co., Ltd., 6Fl., No.1, Sec. 1,Tiding Blvd., Neihu Dist., Taipei City, 11494, Taiwan, R.O.C. TEL:+886-2-2790-0088

Safety Instructions

  1. Read all safety instructions carefully.
  2. Keep this user manual for future reference.

Copyright Notice
The documentation and software included with this product are copyrighted© by Sysgration Co., Ltd. All rights reserved. Sysgration Co., Ltd. reserves the right to improve the products described in this manual at any time without prior notice. No part of this manual may be reproduced, copied, translated, or transmitted in any form or by any means without the prior written permission of Sysgration Co., Ltd. While Sysgration Co., Ltd. strives to ensure the information provided in this manual is accurate and reliable, it assumes no responsibility for its use or for any infringements of the rights of third parties that may result from its use.

Declaration of Conformity
FCC Class A

Note
This equipment has been tested and found to comply with the limits for a Class A digital device of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference, in such cases users will be required to correct the interference at their own expense.

Warning
Any modifications to this device that are not approved by the relevant standards authority may void the authority granted to the user by the FCC to operate this equipment.

Packing List

Before installing the AIX-600 Edge AI Box, check that the following materials have been included in the shipment:

  • AIX-600 unit
  • Accessories for AIX-600
    • Antenna x 2
    • Power Adapter x 1

If any of these items are missing or damaged, contact your distributor or sales representative immediately.

Technical Support and Assistance
Visit the Sysgration website at http://www.sysgration.com to obtain the latest product information.

For technical support or additional assistance, contact your distributor, sales representative, or Sysgration’s customer service center. Please have the following information ready before calling:

  • Product name and serial number
  • Description of your peripheral attachments
  • Description of your software (operating system, version, application software, etc.)
  • A complete description of the problem
  • The exact wording of any error messages

Contact information
Sysgration Co., Ltd.
6Fl., No.1, Sec. 1, Tiding Blvd., Neihu Dist., Taipei City, 11494, Taiwan, R.O.C.
TEL: +886-2-2790-0088

Safety Instructions

  1. Read these safety instructions carefully.
  2. Retain this user manual for future reference.
  3. Disconnect the equipment from all AC outlets before cleaning. Use only a damp cloth for cleaning; do not use liquid or spray detergents.
  4. For pluggable equipment, ensure the power outlet socket is located near the equipment and easily accessible.
  5. Protect the equipment from humidity.
  6. Place the equipment on a stable surface during installation. Dropping or allowing the equipment to fall may cause damage.
  7. The openings of the enclosure are for air convection. Protect the equipment from overheating by not covering the openings.
  8. Verify that the voltage is correct before connecting the equipment to a power outlet.
  9. Position the power cord away from high-traffic areas and avoid placing anything over it.
  10. Note all cautions and warnings on the equipment.
  11. If the equipment will not be used for an extended period, disconnect it from the power source to prevent damage from transient overvoltage.
  12. Never pour liquid into any opening, as this may cause fire or electrical shock.
  13. Never open the equipment. For safety reasons, the equipment should only be opened by qualified service personnel.
  14. Have the equipment checked by authorized service personnel if any of the following occur:
    • The power cord or plug is damaged.
    • Liquid has penetrated the equipment.
    • The equipment has been exposed to moisture.
    • The equipment is malfunctioning or does not operate according to the user manual.
    • The equipment has been dropped or damaged.
    • The equipment shows obvious signs of breakage.
  15. Do not store the equipment in environments where temperatures fluctuate below -40°C(-40°F) or above 80°C(176°F), as this may cause damage. Store the equipment in a controlled environment.

Warning
Because of the risk of electric shock, do not remove the equipment cover during operation or when connected to a power outlet.

Caution!
To avoid short circuits and otherwise damaging the device,do not allow fluids to come in contact with the device. If fluids are accidentally spilled on the equipment, remove the affected unit from service as soon as possible and contact service personnel to verify that personal safety is not compromised.

General Information

Introduction
The AIX-600 is an intelligent edge computing terminal developed based on Qualcomm’s QCS6490 platform, using an octa-core high-performance processor (1+3+4 architecture) with a large core frequency of up to 2.7 GHz.
It integrates a high-performance graphics engine and an AI engine with a comprehensive computing power of about 12 TOPS, and supports 5G NR sub-6G, Wi-Fi 6e (2.4 GHz/5 GHz/6 GHz), BT5.2/BLE, GNSS (Optional, 5G version), and other wireless communication technologies (the 5G version and the Wi-Fi version are slightly different). The AIX-600 edge computing terminal has a rich set of industrial interfaces, including USB 3.0, USB 2.0, USB-C, HDMI, Audio, Ethernet RJ45, and buttons, making it suitable for use in industrial control, smart manufacturing, security monitoring, intelligent robots, digital multimedia, and other fields.
The AIX-600 is based on the QCS6490 SoC and supports multiple operating systems, including Android, Linux, Ubuntu, and Windows IoT. For details on operating system support, please consult the local official sales channel.

Specifications

Function Description
 

 

CPU Processor

Qualcomm QCS6490 Kryo™ CPU 6xx , Octa-core, 1 x A78 @ 2.7GHz

3 x A78 @ 2.4GHz

4 x A55 @1.9 GHz

GPU Adreno 642
Operating system Ubuntu/ Android/ Linux/ Windows IOT*
SIM Card 4FF(Reserved, 5G Version)
Audio Line in, 3.5mm

Line out, 3.5mm

SD Card Support (up to 2TB capacity)
External SSD M.2 M-Key Port, Support WiFi Version
5G M.2 B-Key Port, Support 5G Version. The M-Key and B-Key

can’t exist at the same time currently.

RTC Support RTC, recommend 120mAh@3V, CR1632X
MIPI-DSI interface Onboard connector, compatible with Raspberry Pi DSI 4

lane interface, support TP (verified Raspberry Pi 7 inch)

40 PIN GPIO

interface 1

Onboard connector, compatible Raspberry Pi interface,

typical 3.3V voltage, refer to below table 2.2.2

40 PIN GPIO

interface 2

Refer to below table 2.2.3
Storage RAM: LPDDR4x/5, 8GB

ROM: UFS, 128GB

Power supply DC12V, wide voltage input, recommend PSU typical

12V@5A

Wireless connection Wi-Fi: 802.11ax, 2.4G/5G /6G DBS, 2*2 MIMO

BT: Android 5.3, Linux 5.2, Ubuntu 5.2

Terminal dimension 140 x 115 x 54 mm
Work Temperature -20 °C ~ 60 °C

System Block Diagram

SYSGRATION-AIX-600-Qualcomm-Edge-AI-Box-FIG- (1)

Dimension

SYSGRATION-AIX-600-Qualcomm-Edge-AI-Box-FIG- (2)

Interface Introduction

We provide the AIX-600 tailored to specific application scenarios and testing requirements. The board includes several reserved interfaces, such as MIPI DSI, MIPI CSI, GPIO, fan, and debugging interfaces.

Terminal External Interface

SYSGRATION-AIX-600-Qualcomm-Edge-AI-Box-FIG- (3)

SYSGRATION-AIX-600-Qualcomm-Edge-AI-Box-FIG- (4)

External Interface

Interface No Signal Definition Function Description
1 DC_IN Equipment power input, voltage range: DC12V, typical value 12V@5A
2 LINE OUT Audio Output
3 LINE IN Audio Input
4 USB3.0 USB 3.0 interface, 5V/0.9A
5 HDMI_OUT HDMI 1.4 signal output, resolution/frame rate: 1080p/60fps*
6 USB3.0 USB 3.0 interface, 5V/0.9A
7 HDMI_IN HDMI 1.4 signal input, resolution/frame rate: 720p/30fps
8 WAN RJ45 Ethernet port(User can configure as LAN)
9 LAN RJ45 Ethernet port
10 LAN RJ45 Ethernet port
11 LAN RJ45 Ethernet port
12 WIFI/BT RF 2 Wi-Fi/BT antenna interfaces
13 USB2.0 USB2.0 Interface
14 USB Type-C USB 3.1, 5V/0.9A, support DP

(max resolution: 3840*2160 at 60Hz)

15 POWER Power button; The device is powered on automatically when plug-in the DC power.
16 Volume + Volume up key
17 Volume – Volume down key
18 Micro SD Micro SD card slot
19 Power LED On/Off indicator

DSI and HDMI-out are mutually exclusive, with HDMI-out having higher priority. To use the 7-inch LCD screen, remove HDMI-out before powering on.

Inside Onboard Interface

SYSGRATION-AIX-600-Qualcomm-Edge-AI-Box-FIG- (5)

Inside onboard interface

Interface No Signal Definition Function Description
20 B2B Connector B2B connector 50PIN internal GPIO port connection.
21 RTC connector Real-time-clock for system, recommend 120mAh@3.0V
 

22

 

Qualcomm 40PIN

Qualcomm 40PIN universal interface (including UART, CAN, I2S and other interfaces). See Table 2.2.3 below for details.
23 Force boot Forced download port (used in emergencies).
24 Fan Fan interface, see table 2.2.5 below for details.
25 LCD connector Connect display screen. See Table 2.2.4 below for details.
 

26

 

Raspberry 40PIN

Raspberry Pi display 40PIN functional interface (including GPIO, UART and other interfaces). See Table 2.2.2 below for details.
27 Raspberry Camera Connector 22PIN Raspberry Pi Camera connector, connect to Camera, see Table 2.2.4 below for details.
28 Raspberry Camera Connector 22PIN Raspberry Pi Camera connector, connect to Camera, see Table 2.2.4 below for details.
29 Camera connector 30pin C-PHY interface, see below table 2.2.6

Raspberry PI 40PIN interface signals

PIN Signal Definition Function Description

(All GPIO signals of the interfaces are 3 .3V)

1 3V3 3.3V Power
2 5V 5 V Power
3 GPIO00 Can be configured as I2C needs to be combined with GPIO1 or ordinary GPIO
4 5V 5 V Power
5 GPIO01 Can be configured as I2C needs to be combined with GPIO00 or ordinary GPIO
6 GND Ground
7 GPIO76 Normal GPIO or PWM (GCC_GP1_CLK_MIRB)
8 UART_TX Can be configured as QUP0_SE3 UART or ordinary GPIO14
9 GND Ground
10 UART_RX Can be configured as QUP0_SE3 UART or ordinary GPIO 15
11 GPIO129 Ordinary GPIO
12 I2S0_SCK I2S0 Interface,It can also be configured as a normal GPIO
13 GPIO62 Can be configured as QUP1_SE7 UART or Normal GPIO
14 GND Ground
15 GPIO63 Ordinary GPIO
16 GPIO35 Ordinary GPIO
17 3V3 3.3V Power
 

18

 

GPIO41

Can be configured as SPI or UART+GPIO (when full-featured UART is not required) or I2C+GPIO or GPIO
 

19

QUP1_SE4_SPI_ MOSI QUP1_SE4, can be configured as SPI or UART+GPIO (when full-featured UART is not required) or I2C+GPIO or GPIO
20 GND Ground
 

21

QUP1_SE4_SPI_ MISO QUP1_SE4, can be configured as SPI or UART+GPIO (when full-featured UART is not required) or I2C+GPIO or GPIO
 

22

 

GPIO54

1.   Ordinary GPIO. If DSI TP is not used, it can be configured as UART (needs to be combined with GPIO55);

2.   QUP1_SE4_SPI CS2

 

23

QUP1_SE4_SPI_ SCLK QUP1_SE4, can be configured as SPI or UART+GPIO (when full-featured UART is not required) or I2C+GPIO or GPIO
 

24

QUP1_SE4_SPI_ CS0 QUP1_SE4, can be configured as SPI or UART+GPIO (when full-featured UART is not required) or I2C+GPIO or GPIO
25 GND Ground
 

26

 

GPIO55

1.   Ordinary GPIO, if DSI TP is not used, it can be configured as UART (needs to be combined with GPIO54)

2.   QUP1_SE4_SPI CS1

27 ID_SD QUP0_SE2_I2C is reserved and can be configured as ordinary GPIO
28 ID_SC QUP0_SE2_I2C is reserved and can be configured as ordinary GPIO
29 GPIO34 Common GPIO
30 GND Ground
31 GPIO42 Ordinary GPIO
32 GPIO77 Ordinary GPIO, GCC_GP2_CLK_MIRB
33 GPIO78 Ordinary GPIO, GCC_GP3_CLK_MIRB
34 GND Ground
35 I2S0_WS I2S0 Interface, Can be configured as ordinary GPIO
36 GPIO43 Ordinary GPIO
37 GPIO40 Ordinary GPIO
38 I2S0_DATA0 I2S0 Interface, Can be configured as ordinary GPIO
39 GND Ground
40 I2S0_DATA1 I2S0 Interface, Can be configured as ordinary GPIO

Qualcomm 40PIN Interface

PIN Signal Definition Function Description

(All GPIO signals of the interfaces are 3 .3V)

 

 

1

 

 

GPIO36

QUP1_SE1 can be configured as SPI or UART+GPIO (when full-featured UART is not required) or I2C+GPIO or GPIO. GPIO36/GPIO37 is compatible with RTC INT1/INT2 currently. When the RTC function is not needed, adjust R1821-R1822/ R1823-R1834 to restore the full-featured QUP
 

2

 

1V8

The 1.8V power supply is used for external power supply. It is only recommended to be used as a pull-up power supply for the IO port.
 

 

3

 

 

GPIO37

QUP1_SE1 can be configured as SPI or UART+GPIO (when full-featured UART is not required) or I2C+GPIO or GPIO. GPIO36/GPIO37 is compatible with RTC INT1/INT2 currently. When the RTC function is not needed, adjust R1821-R1822/ R1823-R1834 to restore the full-featured QUP
4 GND Ground
 

 

5

 

 

GPIO38

QUP1_SE1 can be configured as SPI or UART+GPIO (when full-featured UART is not required) or I2C+GPIO or GPIO. GPIO36/GPIO37 is compatible with RTC INT1/INT2 currently. When the RTC function is not needed, adjust R1821-R1822/ R1823-R1834 to restore the full-featured QUP
6 LPI_I2S1_CLK LPI I2S AUDIO INTERFACE 1, Can also be configured as DMIC1 Interface
 

 

7

 

 

GPIO39

QUP1_SE1 can be configured as SPI or UART+GPIO (when full-featured UART is not required) or I2C+GPIO or GPIO. GPIO36/GPIO37 is compatible with RTC INT1/INT2 currently. When the RTC function is not needed, adjust R1821-R1822/ R1823-R1834 to restore the full-featured QUP
8 LPI_I2S1_WS LPI I2S AUDIO INTERFACE 1, Can also be configured as DMIC1 Interface
9 GND Ground
10 LPI_I2S1_DATA0 LPI I2S AUDIO INTERFACE 1, Can also be configured as DMIC2 Interface
 

11

 

GPIO56

QUP1_SE6, can be configured as SPI or UART+GPIO (when full-featured UART is not required) or I2C+GPIO or GPIO
12 LPI_I2S1_DATA1 LPI I2S AUDIO INTERFACE 1, can also be configured as DMIC2 Interface
 

13

 

GPIO57

QUP1_SE6, can be configured as SPI or UART+GPIO (when full-featured UART is not required) or I2C+GPIO or GPIO
14 GND Ground
 

15

 

GPIO58

QUP1_SE6, can be configured as SPI or UART+GPIO (when full-featured UART is not required) or I2C+GPIO or GPIO
16 VREG_L8C L8C sensor 1V8 Power, MAX 15mA
 

17

 

GPIO59

QUP1_SE6, can be configured as SPI or UART+GPIO (when full-featured UART is not required) or I2C+GPIO or GPIO
18 LPI_I2C2_SCL LPI_I2C2 for Sensor
19 LPI_I2C0_SCL LPI_I2C0 for Sensor
20 LPI_I2C2_SDA LPI_I2C2 for Sensor
21 LPI_I2C0_SDA LPI_I2C0 for Sensor
22 LPI_I2C1_SCL LPI_I2C1 for sensor
 

23

PM7250B_ GPIO11 PMU7250B GPIO LV is reserved for controlling the power supply of QCA8337, and the external output can be disconnected through the R1820 resistor.
24 LPI_I2C1_SDA LPI_I2C1 for sensor
25 PM7250B_ GPIO12 PMU7250B GPIO LV
26 LPI_GPIO155 LPI_GPIO155 can be configured as LPI_I2S2
 

27

 

DEBUG_UART_TX

Can be configured as an ordinary GPIO, used as a debug serial port by default, or as an ordinary serial port.
28 VOUT_5V 5V power supply is output externally, and the current should not exceed 500mm.
 

29

DEBUG_UART_ RX Can be configured as an ordinary GPIO, used as a debug serial port by default, or as an ordinary serial port.
30 LPI_GPIO154 LPI_GPIO154 can be configured as LPI_I2S2
31 LPI_DMIC3_CLK DMIC3 INTERFACE
32 PM7325_ADC_ AMUX1_GPIO02 ADC IN_PUT channel 1
33 LPI_DMIC3_DATA DMIC3 INTERFACE can be configured as LPI_I2S2
34 GND Ground
35 GND Ground
36 PM7325_ADC_ AMUX1_GPIO02 ADC IN_PUT channel 2
37 CAN_L CAN bus interface
38 GND Ground
39 CAN_H CAN bus interface
40 PWM_OUT PWM output, reserved for fans currently

CSI interface (Raspberry D-PHY)

PIN Signal Definition Function Description

(All GPIO signals of the interfaces are 3 .3V)

1 GND Ground
2 CAM1_D0_N MIPI DATA LAN0 N
3 CAM1_D0_P MIPI DATA LAN0 P
4 GND Ground
5 CAM1_D1_N MIPI DATA LAN1 N
6 CAM1_D1_P MIPI DATA LAN1 P
7 GND Ground
8 CAM1_CLK_N MIPI CLK N
9 CAM1_CLK_P MIPI CLK P
10 GND Ground
11 CAM1_D2_N MIPI DATA LAN2 N
12 CAM1_D2_P MIPI DATA LAN2 P
13 GND Ground
14 CAM1_D3_N MIPI DATA LAN3 N
15 CAM1_D3_P MIPI DATA LAN3 P
16 GND Ground
17 CAM_GPIO Camera Power On
18 CAM_LED EN LED EN
19 GND Ground
20 SCL0 Camera I2C SCL0
21 SDA0 Camera I2C SDA0
22 +3.3V Power 3.3V

Fan Interface

PIN Signal Definition Function Description
1 5V Power 5V
2 PWM INPUT PWM signal
3 / /
4 GND Ground

C-PHY interface

PIN Signal Definition PIN  
1 DGND 16 AFVDD-2V8
2 CS1_C2 17 CCI_SCL
3 CS1_B2 18 CCI_SDA
4 CS1_A2 19 CAM_RST
5 DGND 20 PWDN
6 CS1_C1 21 AGND
7 CS1_B1 22 DVDD_1V1
8 CS1_A1 23 VSYNC
9 DGND 24 AGND
10 CS1_C0 25 AVDD-2V9
11 CS1_B0 26 DOVDD_1V8
12 CS1_A0 27 DGND
13 DGND 28 DVDD_1V1
14 DGND 29 DVDD_1V1
15 MCLK 30 DGND

Status Light

LED Status Color Frequency
Power Power-on Red Always on
Standby Green Always on

RF parameters

AIX-600 product supports Wi-Fi only version and 5G+Wi-Fi version. Different versions have different antenna configurations.

WIFI radio frequency parameters

Parameter Characteristic
Antenna type External SMA antenna, 2
Impedance 50Ω
 

 

 

 

 

 

 

Frequency Range

2.4GHz

802.11b/g/n/ax(20M): 2412-2472MHz

802.11n/ax(40M): 2422-2462MHz

 

5GHz

802.11a/n/ac/ax(20M): 5180-5825MHz

802.11n/ac/ax(40M): 5190-5795MHz

802.11ac/ax(80M): 5210-5775MHz

802.11ax(160M): 5250-5570MHz

6GHz

802.11ax(20M): 5955-7115MHz

802.11ax(40M): 5965-7085MHz

802.11ax(80M): 5985-7025MHz

802.11ax(160M): 6025-6985MHz

Modulation Way BPSK, QPSK, 16-QAM, 64-QAM, 256-QAM, 1024-QAM
Frequency Interval 5 MHz

Electrical and Environmental Parameters

Electrical and Environmental parameters

Parameter Minimum value Typical value Maximum value Unit
Power input 10.2 12 13.8 V
working temperature -20 25 60
Storage temperature -40 25 80
Working environment humidity 20 40 90 %

Power Dissipation

Parameter Power (W, Max .) Remark
PSU 60 12V/5A
System Input 18 QCS6490 Module
USB3.0 x 4 18 5V, 900mA
USB2.0 x 1 4.5 5V, 900mA
5G Module* 10 FM160 Module
SSD 5.8 Read
5.6 Write

* 5G module/SSD are in either different SKU

Device Firmware

Device Firmware Flashing Procedure Using Qualcomm QFIL Tool

Connecting and Setting Up Your Interface

  1. Plug in the HDMI Cable: Connect an HDMI cable between the monitor and interface 5 (HDMI_OUT).
  2. Power On: Press the Power On button for 3 seconds until a green LED light flashes. Ensure that you plug in the HDMI cable before powering on the device.
  3. Verify Display: You should see the image on the monitor. Once the HDMI output display is normal, you can unplug and reinsert the HDMI cable, and it should still display correctly.
  4. Connect Peripherals: Connect the mouse and keyboard to ports 4 or 6 (USB 3.0). The following icon “Weston-terminal” should appear on the screen.
  5. Access the Command Line Interface: Click on the Weston-terminal icon in the upper left corner of the screen to open the command line interface.
  6. Enter Commands: Use the command line interface to enter commands and access the system.
  7. Additional Connectivity: You can also connect port 14 (USB Type-C) to your PC using a USB cable. If your PC has an ADB environment installed, you can enter commands on your PC to access the system.

SYSGRATION-AIX-600-Qualcomm-Edge-AI-Box-FIG- (6)

Flashing Firmware Using Qualcomm QFIL Tool

Note
Download the QFIL Tool to assist in flashing or installing firmware on devices powered by Qualcomm chipsets. The tool can be downloaded here: https://qfiltool.com/#google_vignette

  1. Power On and Connect: Power on the device and connect it to the computer using the USB Type-C port.
  2. Open Qualcomm QFIL Tool: Launch the Qualcomm QFIL tool, go to the download configuration interface, and select the appropriate configuration settings.SYSGRATION-AIX-600-Qualcomm-Edge-AI-Box-FIG- (7)
  3. Execute ADB Commands: Enter the following ADB commands:
    Copy code adb root adb reboot edl
    After running these commands, the QDLoader download port should appear, as shown in the image below.SYSGRATION-AIX-600-Qualcomm-Edge-AI-Box-FIG- (8)
  4. Select Flat Build Option: Choose the “Flat Build” option and then select the prog_firehostedr.elf file from the version directory.SYSGRATION-AIX-600-Qualcomm-Edge-AI-Box-FIG- (9)
  5. Load XML File: Click the “Load XML” button to load the XML file. Select“All” twice, as depicted in the image below.SYSGRATION-AIX-600-Qualcomm-Edge-AI-Box-FIG- (10)
  6. Start Download: Click the “Download” button to begin the flashing process. Once you receive a success message, you can exit the tool.

SYSGRATION-AIX-600-Qualcomm-Edge-AI-Box-FIG- (11)

Make sure to follow the steps in the order provided for successful firmware flashing.

Contact information
Sysgration Co., Ltd.
6Fl., No.1, Sec. 1, Tiding Blvd., Neihu Dist., Taipei City, 11494, Taiwan, R.O.C.
TEL: +886-2-2790-0088

FAQ

Q: Can I open the device for maintenance?
A: No, for safety reasons, the equipment should only be opened by qualified service personnel.

Q: What should I do if liquids come in contact with the device?
A: If fluids are accidentally spilled on the equipment, remove the affected unit from service immediately and contact service personnel to ensure personal safety is not compromised.

Documents / Resources

SYSGRATION AIX-600 Qualcomm Edge AI Box [pdf] User Manual
AIX-600, AIX-600 Qualcomm Edge AI Box, Qualcomm Edge AI Box, Edge AI Box, AI Box

References

Leave a comment

Your email address will not be published. Required fields are marked *