Nembo ya ufundi

Technity SOLUTIONS TS-MWO2400C Series Wireless Access Point

Technity-SOLUTIONSTS-MWO2400C-Series-Wireless-Access-Point-bidhaa

Bidhaa Imeishaview

TS-MWO2400C, inaambatana na kiwango cha hivi punde zaidi cha 802.11 ax, ni sehemu ya ufikiaji isiyo na waya (AP) iliyoundwa na Corning. Ikijumuisha mitiririko miwili ya anga kila redio, AP hii ya redio mbili na bendi mbili hutoa kiwango cha ufikiaji hadi 575 Mbps katika 2.4G na 1,200 Mbps kwa 5G, jumla ya 1. 775 G bps. Na bandari ya 10/100/1 000Base-T Ethernet na bandari ya SF P inaweza kutumika kwa sasa.

Vipimo vya Kiufundi

Jedwali1- 1 TS-MWO2400C Vipimo vya KiufundiTechnity-SOLUTIONSTS-MWO2400C-Series-Wireless-Access-Point-fig- (1)Technity-SOLUTIONSTS-MWO2400C-Series-Wireless-Access-Point-fig- (2)Technity-SOLUTIONSTS-MWO2400C-Series-Wireless-Access-Point-fig- 19

Taa za Jedwali za TS-MWO2400C

LED Jimbo Maana
 

 

 

Hali ya mfumo

Kijani kumeta Mfumo unaanza.
 

Kijani thabiti

Uanzishaji unaendelea au

operesheni sahihi.

blinking

machungwa

Uanzishaji umekamilika, lakini hapana

Muunganisho wa CAPWAP.

Nyekundu inayopepea Lango la juu limekatwa.
WDS RSSI (LEDs 3 ndani

jumla; inapatikana wakati uunganishaji umewashwa)

1 thabiti juu <-?0dBm
2 thabiti juu -70 hadi -50dBm
3 thabiti juu > -50dBm

Kitufe cha Kuweka upya Jedwali la TS-MWO2400C

Kitufe Jimbo Maana
 

Weka upya kitufe

Inapowashwa, imebonyezwa kwa chini ya sekunde 2  

Huweka upya AP.

Wakati imewashwa, bonyeza kwa zaidi

zaidi ya 3s

Hurejesha kiwanda

mipangilio ya chaguo-msingi.

Muonekano wa Bidhaa

Kielelezo1-1 Muonekano wa Bidhaa wa S-MWO2400C

Technity-SOLUTIONSTS-MWO2400C-Series-Wireless-Access-Point-fig- (3)

 

Kumbuka:

1. Mlango wa Condole na kitufe cha kuweka upya

2. Bandari ya usambazaji wa umeme wa 48 V DC

3. 10/100/1000Base-T

bandari ya Ethernet/PoE ya kuhisi kiotomatiki

4. SFP bandari

Ugavi wa Nguvu
AP inaauni usambazaji wa umeme wa 802.3af PoE au 57 V DC.

  • Wakati usambazaji wa nishati ya PoE unatumiwa, tafadhali hakikisha kwamba kifaa rika kinaauni 802.3af/802.3at, pia.
  • Mahitaji ya chini kabisa ya sasa ya usambazaji wa umeme wa DC ni 0.35 A

Kujiandaa kwa Ufungaji

  • Ili kuzuia uharibifu wa kifaa na majeraha ya kimwili, tafadhali soma kwa makini mapendekezo ya usalama yaliyofafanuliwa katika sura hii.
  • Mapendekezo hayajumuishi hali zote hatari zinazowezekana.

Ulinzi wa Kutuliza na Umeme 

  • Hakikisha kwamba mwisho wa kupokea nishati na mwisho wa ugavi ni msingi mzuri.
  • Weka muunganisho wa kutuliza ndani ya m 30, na utumie bapa ya 40mm x 4mm au 50mm x 5mm ya chuma bapa iliyopakwa zinki-moto.
  • Wakati kebo ya uunganisho kati ya kondakta mkuu wa kutuliza na bodi ya terminal ya ardhi ya equipotential (LEB) kwenye kila sakafu ni fupi kuliko mita 2, tumia waya wa shaba iliyopigwa na eneo la sehemu si chini ya 1.318 mm2 (16 AWG) kwa cable ya uunganisho.
  • Tumia kebo ya mtandao iliyolindwa ikiwezekana, hakikisha kuwa vifaa vilivyounganishwa kwenye ncha zote mbili za kebo ya mtandao iliyolindwa vimewekewa msingi kwa njia inayotegemeka, na uhakikishe kwamba ala ya kebo ya mtandao iliyolindwa pia imezimwa ikiwa inawezekana. Iwapo hakuna kebo ya mtandao iliyolindwa inayopatikana, tia kebo ya mtandao kupitia bomba la chuma na uzike bomba la chuma kwa ajili ya kuingiza, na kusaga vizuri ncha zote mbili za chuma.
  • Hakuna mlinzi wa ziada wa umeme anayehitajika kama mtaalamu wa hali ya juufile ulinzi wa umeme umejengwa katika TS-MWO2400C, na bandari ya nguvu inasaidia ulinzi wa umeme wa 6kV. Ikiwa mlinzi wa umeme wa mtaalamu wa juufile inapatikana, sanidi mlinzi wa umeme kwa hiari. Kabla ya usanidi, unganisha mlinzi wa umeme kwenye cable ya chini.
  • Tumia kebo ya umeme yenye ncha ya PE ili kusitisha usambazaji wa nishati (AC). Hakikisha kwamba mwisho wa PE umewekwa msingi, na upinzani wa ardhi chini ya 5 ohms. Usitumie kebo ya umeme ya waya mbili iliyo na waya wa moja kwa moja (L) na waya tupu (N). Usiunganishe waya wa N kwenye kebo ya ardhi ya ulinzi ya vifaa vingine vya mawasiliano, na uhakikishe kuwa waya wa L na waya wa N zimeunganishwa ipasavyo.
  • Hakikisha kwamba upinzani wa ardhi ni chini ya 5 ohms. Katika maeneo yenye upinzani wa juu wa udongo, punguza upinzani wa udongo kupitia hatua kama vile kueneza mchanganyiko wa kupunguza upinzani karibu na kondakta ya kutuliza.

Kuandaa Tovuti ya Ufungaji

  • Usiweke AP kwenye joto la juu, vumbi, au gesi hatari.
  • Usisakinishe AP katika eneo linalokumbwa na moto au halijoto ya juu
  • Weka AP mbali na vyanzo vya EMI kama vile vituo vikubwa vya rada, vituo vya redio na vituo vidogo.
  • Usiweke AP kwa juzuu isiyo thabititage, mtetemo, na kelele.
  • Weka AP angalau mita 500 kutoka kwa bahari na usikabiliane nayo kuelekea upepo wa baharini.
  • Tovuti ya ufungaji inapaswa kulindwa kutokana na maji na mafuriko, maji ya mvua, matone, au condensation.
  • Tovuti ya usakinishaji inapaswa kuchaguliwa kulingana na upangaji wa mtandao, sifa za vifaa vya mawasiliano na maswala kama vile hali ya hewa, haidrolojia, jiolojia, tetemeko la ardhi, nguvu za umeme, na usafirishaji.

Joto na Unyevu

Jedwali 2-1 Halijoto Inayohitajika na Unyevu kwa TS-MWO2400C

perating Joto -40°C hadi 65°C (-40°F hadi 149°F)
Kupunguza Unyevu 0% hadi 100% (isiyopunguza)

Ufungaji wa nje
AP inaweza kuwekwa kwenye ukuta au nguzo.

Kuzuia maji
Tumia kuziba kuziba bandari ambazo hazijatumika.

Kielelezo 2-1 Seal Plug Technity-SOLUTIONSTS-MWO2400C-Series-Wireless-Access-Point-fig- (4)
Tumia adapta isiyozuia maji kuunganisha nyaya kwenye AP. Kwa maelezo, angalia Sura ya 3 "Kusakinisha Mahali pa Kufikia".

EMI 

Vyanzo vyote vya mwingiliano (kutoka nje au ndani ya kifaa au mfumo wa programu) huathiri kifaa kwa uunganisho wa capacitive, uunganishaji wa kufata neno, au mawimbi ya sumakuumeme. Uingiliaji wa sumakuumeme (EMI) hutokea kutokana na mionzi ya sumakuumeme au upitishaji, kulingana na njia ya upitishaji.

Kuingilia kwa mionzi hutokea wakati nishati (kawaida nishati ya masafa ya redio) inatolewa kutoka kwa kifaa na kuenezwa kupitia nafasi ili kutatiza vifaa vingine. Chanzo cha kuingilia kati kinaweza kuwa sehemu ya mfumo uliovurugika au kitengo kilichotengwa kikamilifu na umeme. Uingiliaji wa upitishaji hutokea wakati mwingiliano unapohamishwa kutoka kitengo kimoja hadi kingine kupitia kebo, ambazo kwa kawaida ni nyaya za sumakuumeme au kebo za mawimbi zilizounganishwa kati ya chanzo na kifaa/vifaa vinavyoathiriwa. Uingiliaji wa uendeshaji mara nyingi huathiri usambazaji wa nguvu wa kifaa. Inaondolewa kwa kutumia filters. Kuingiliwa kwa mionzi kunaweza kuathiri njia ya ishara yoyote kutoka kwa kifaa na ni vigumu kukinga.

  • Chukua hatua madhubuti dhidi ya kuingiliwa kutoka kwa gridi ya umeme.
  • Weka AP mbali na vifaa vya ulinzi wa kutuliza au umeme kwa vifaa vya nguvu.
  • Weka AP mbali na vituo vya redio vya nguvu za juu, vituo vya rada na vifaa vya masafa ya juu.
  • Chukua hatua za ulinzi wa kielektroniki.

Uunganisho wa nyuzi
Kabla ya kuunganisha nyaya za nyuzi, hakikisha mfano wa transceiver ya macho na aina ya fiber inafanana na bandari ya macho. Lango la kusambaza kwenye kifaa cha ndani linapaswa kuunganishwa kwenye mlango wa kupokea kwenye kifaa cha programu rika na kinyume chake.

Zana za Ufungaji

Jedwali 2- 2 Zana za Ufungaji

Zana
Alama, Phillips (crosshead) bisibisi, bisibisi iliyofungwa, kuchimba visima, kisu cha karatasi, koleo la kubana, koleo la diagonal, stripper ya waya, kijaribu kebo ya mtandao, nyaya za nguvu na nyuzinyuzi zinazohusiana, wrench, nyundo, vifungo vya kebo, zana za ESD, multimeter, mkanda wa kupitishia maji. , plasta isiyo na maji

Seti ya zana na nyaya hutolewa na mteja.

Kuangalia kabla ya Ufungaji
Tafadhali angalia nyenzo zako kwa uangalifu dhidi ya yaliyomo kwenye kifurushi. Ikiwa kuna makosa yoyote, tafadhali wasiliana na msambazaji wako

Kufunga Pointi ya Ufikiaji
Kabla ya kusakinisha AP, hakikisha kuwa umesoma kwa makini mahitaji yaliyoelezwa katika Sura ya 2

Ufungaji Flowchart

Technity-SOLUTIONSTS-MWO2400C-Series-Wireless-Access-Point-fig- (5)

Kabla Hujaanza
Kabla ya kusakinisha AP, thibitisha kuwa sehemu zote kwenye yaliyomo kwenye kifurushi zipo na uhakikishe kuwa:

  • Tovuti ya ufungaji inakidhi mahitaji ya joto na unyevu.
  • Tovuti ya ufungaji ina vifaa vya kutosha vya umeme.
  • Kebo za mtandao zipo.

Tahadhari

TS-MWO2400C inaweza kupandwa kwenye ukuta na nguzo (kipenyo: 50mm hadi 140mm, unene2: .5mm). Vinginevyo, AP inaweza kuanguka chini na kusababisha majeraha. Tovuti ya usakinishaji inaweza kutofautiana kutokana na tafiti za papo hapo zinazofanywa na wafanyakazi wa kiufundi. Tafadhali fanya maandalizi kamili kama ilivyoelezwa katika Sura ya 2 na uzingatie tahadhari zifuatazo kabla ya kusakinisha AP.

  • Kabla ya kuunganisha ugavi wa umeme, hakikisha ugavi wa umeme wa nje unalingana na moduli ya nguvu ndani ya AP.
  • Kabla ya kuunganisha waya wa umeme, hakikisha kuwa swichi ya umeme iko katika hali ya IMEZIMWA.
  • Wakati wa kuunganisha waya kwenye chapisho la kuunganisha, hakikisha rangi zao ni sawa.
  • Hakikisha kuwa umeme umeunganishwa vizuri.

Kufunga AP

  1. Tumia skrubu nne za M5 ili kulinda AP kwenye bati la kupachika.
    Kielelezo 3-1 Kulinda AP na Screws za M5Technity-SOLUTIONSTS-MWO2400C-Series-Wireless-Access-Point-fig- (6)
  2. Weka bracket iliyowekwa kwenye nguzo au ukuta.
    • Mlima wa pole:
      Ambatanisha bracket kwenye nguzo yenye hose mbili za clamps na funga clamp na screws na karanga.
      Mchoro 3-2 Kuweka Mabano kwenye NguzoTechnity-SOLUTIONSTS-MWO2400C-Series-Wireless-Access-Point-fig- (7)
    • Mlima wa ukuta:
      Tumia skrubu nne za M8 x 60 kutekeleza kiweka ukuta. (Skurubu, zilizotengenezwa kwa chuma cha pua cha SUS304, hutolewa na mteja.)
      • Ambatanisha mabano kwenye ukuta na uweke alama maeneo ya tundu la skrubu.
      • Pangilia tundu za skrubu kwenye mabano na zile zilizo ukutani, na kaza skrubu za M8x40 ili kupachika mabano.
        Mchoro 3-3 Kuweka Mabano UkutaniTechnity-SOLUTIONSTS-MWO2400C-Series-Wireless-Access-Point-fig- (8)
  3. Tumia skrubu nne za M6 ili kuunganisha bati la kupachika na mabano. Rekebisha pembe ya kifaa kabla ya kufunga screws. Kielelezo 3-4 Kamilisha UfungajiTechnity-SOLUTIONSTS-MWO2400C-Series-Wireless-Access-Point-fig- (9)

Kuunganisha Cables 

Kuunganisha cable ya kutuliza
Cable ya kutuliza inafanywa kwenye tovuti. Unganisha waya wa kutuliza uliotolewa (njano-kijani) kwenye shimo la kutuliza la AP kwenye upande mmoja na usage waya upande mwingine kupitia vituo vya OT. Ili kuepuka kupoteza, rekebisha urefu wa kebo kwa mahitaji halisi.

Kielelezo 3-5 Kuweka AP Technity-SOLUTIONSTS-MWO2400C-Series-Wireless-Access-Point-fig- (10)

Kuunganisha kebo ya mtandao
Nyenzo za kuzuia maji hutolewa na mteja

  1. Punguza kebo ya mtandao kulingana na umbali kati ya AP na usambazaji wa umeme. Na kuweka cable trimmed kupitia mabano.
  2. Piga cable kupitia adapta ya kioevu-tight na kuongeza kuziba hadi mwisho. Tazama takwimu 3-6.
    Kielelezo 3-6 Kusambaza Kebo ya MtandaoTechnity-SOLUTIONSTS-MWO2400C-Series-Wireless-Access-Point-fig- (11)
  3. Funga kebo kati ya B na C kwenda juu kwa tabaka mbili au tatu za nyenzo zisizo na kioevu. Tazama takwimu 3-7.
    Mchoro 3- 7 Ufungaji Nyenzo isiyopitisha Kimiminika kwenye KeboTechnity-SOLUTIONSTS-MWO2400C-Series-Wireless-Access-Point-fig- (12)
  4. Ingiza plagi kwenye mlango wa 10G ETH/PoE na kaza B, C na D kwa mpangilio.
    Hakikisha plug imeingizwa kwa usahihi. Plug inaweza kuharibiwa ikiwa adapta isiyo na kioevu imeimarishwa vibaya
    Kabla ya kuondoa kebo ya mtandao, vunja adapta isiyo na kioevu kwanza na kisha kuziba

Kuunganisha nyuzi macho (Si lazima)
Nyenzo za kuzuia maji hutolewa na mteja.

  1. Chagua nyuzi ya macho ya LC-LC yenye kipenyo cha 2.7±0.2mm. 5) Piga nyuzi kupitia adapta isiyo na kioevu kwa mpangilio kama inavyoonyeshwa kwenye takwimu 3-8.
    Kielelezo 3- 8 Kufunga Nyuzinyuzi
  2. Ingiza plagi ya nyuzi kwenye lango la SPF.
  3. Kaza A.
  4. Changanya B na C na uweke mchanganyiko katika A.
  5. Kaza D kabla ya kupaka gundi isiyozuia maji kwenye kiungo chake na A.
    Kabla ya kuondoa nyuzinyuzi ya macho, vunja adapta isiyo na kioevu kwanza na kisha kuziba.
    Ikiwa kipenyo cha fiber LC-LC si 2.7±0.2mm, kuzuia maji ya adapta hawezi kuhakikishiwa.

Kuunganisha waya ya umeme ya DC (Si lazima)
Nyenzo za kuzuia maji hutolewa na mteja. Unapochagua usambazaji wa umeme wa DC ili kuwasha AP, tafadhali hakikisha mlango wa usambazaji wa umeme wa DC uko chini.

Unganisha waya ya umeme ya DC kupitia adapta isiyo na kioevu kwa mpangilio kama inavyoonyeshwa kwenye Mchoro 3-9. Tumia mkanda wa kupitishia maji usio na maji na plasta isiyozuia maji ili kujaza nafasi kati ya kamba ya umeme na adapta. Kielelezo 3- 9 Kuunganisha Kamba ya Umeme ya DC

Technity-SOLUTIONSTS-MWO2400C-Series-Wireless-Access-Point-fig- (14)

Kiambatisho A Mapendekezo ya Cabling 

Wakati wa ufungaji, vifurushi vya cable vya njia juu au chini kando ya pande za rack kulingana na hali halisi katika chumba cha vifaa. Viunganishi vyote vya cable vinapaswa kuwekwa chini ya baraza la mawaziri badala ya kuwa wazi nje ya baraza la mawaziri. Kamba za umeme zinapaswa kuelekezwa juu au chini kando ya kabati karibu na eneo la kabati ya usambazaji umeme ya DC, sehemu ya umeme ya AC, au sanduku la ulinzi la umeme.

Inahitajika Kiwango cha chini cha Kipenyo cha Kupinda cha Cable

  • Radi ya chini ya bend ya kebo ya nguvu, mawasiliano au gorofa inapaswa kuwa mara 5 ya kipenyo cha jumla cha kebo. Ikiwa cable inapigwa mara kwa mara, imefungwa au haijaunganishwa, radius ya bend inapaswa kuwa mara 7 ya kipenyo cha jumla.
  • Radi ya chini ya bend ya kebo Koaxial inapaswa kuwa mara 7 ya kipenyo cha jumla cha kebo. Ikiwa cable inapigwa mara kwa mara, imefungwa au haijazimwa, radius ya bend inapaswa kuwa mara 10 ya kipenyo cha jumla.
  • Kipenyo cha chini zaidi cha kupinda cha kebo ya kasi ya juu, kama vile kebo ya SFP+ inapaswa kuwa mara 5 ya kipenyo cha jumla cha kebo. Ikiwa cable inapigwa mara kwa mara, imefungwa au haijazimwa, radius ya bend inapaswa kuwa mara 10 ya kipenyo cha jumla.

Tahadhari kwa Uunganishaji wa Cable

  • Kabla ya kuunganisha nyaya, weka alama kwa usahihi na ushike lebo kwenye nyaya inapofaa.
  • Kebo zinapaswa kuunganishwa vizuri na vizuri, kama inavyoonyeshwa kwenye Mchoro C-1.
    Kielelezo C-1 Kuunganisha nyayaTechnity-SOLUTIONSTS-MWO2400C-Series-Wireless-Access-Point-fig- (15)
  • Nguvu ya njia na kifungu, mawimbi na nyaya za ardhini kando kando. Wakati nyaya ziko karibu na kila mmoja, zivuke. Wakati nyaya za nguvu zinaendana na nyaya za ishara, umbali kati yao lazima uwe zaidi ya 30 mm.
  • Tray zote za cable na vifaa vyake vitakuwa laini na visivyo na ncha kali.
  • Mashimo ya chuma, ambayo nyaya hupita zitakuwa na nyuso laini, zenye mviringo au kulindwa na misitu ya kuhami joto.
  • Tumia viunganisho vya kebo sahihi ili kuunganisha nyaya. Usifunge kebo mbili au zaidi ili kuunganisha nyaya.
  • Kata tie ya ziada ya kebo kwa usafi bila kingo kali baada ya kuunganisha nyaya, kama inavyoonyeshwa kwenye Mchoro C-2.
    Kielelezo C-2 Kukata Kiunga cha Kebo ZilizozidiTechnity-SOLUTIONSTS-MWO2400C-Series-Wireless-Access-Point-fig- (16)
  • Iwapo nyaya zitapinda, zifunge kwanza lakini usifunge viunganishi vya kebo ndani ya upinde ili kuepuka mkazo kwenye nyaya, jambo ambalo linaweza kusababisha nyaya zilizo ndani kukatika, kama inavyoonyeshwa kwenye Mchoro C-3.
    Kielelezo C-3 Usifunge Viunga vya Kebo ndani ya BendTechnity-SOLUTIONSTS-MWO2400C-Series-Wireless-Access-Point-fig- (17)
  • Funga nyaya zisizohitajika au za ziada na uzifunge kwenye nafasi inayofaa ya rack, ambapo uendeshaji wa kifaa hauathiriwa na hakuna uharibifu unaotokea kwa kifaa na nyaya wakati wa utatuzi.
  • Usifunge kamba za nguvu kwenye reli za kusonga
  • Acha urefu fulani wa kebo inayounganisha sehemu zinazosonga, kama vile waya wa chini wa mlango wa baraza la mawaziri, ili kuzuia mkazo kwenye kebo; Wakati sehemu zinazosogezwa zimewekwa, hakikisha urefu wa ziada wa kebo hautagusa vyanzo vya joto, kona kali au Ikiwa vyanzo vya joto haviepukiki, tumia nyaya za halijoto ya juu badala yake.
  • Wakati wa kutumia skrubu ili kufunga vibao vya kebo, boliti au kokwa zitaimarishwa na kuzuiwa kulegea, kama inavyoonyeshwa kwenye Mchoro C-4.
    Kielelezo C-4 Kufunga Cable Lugs
    Technity-SOLUTIONSTS-MWO2400C-Series-Wireless-Access-Point-fig- (18)
     

    Kumbuka:

    1. Washer wa gorofa

    2. Nut

    3. Washer wa spring

    4. Washer wa gorofa

  • Unapotumia kebo ngumu, itengeneze karibu na kizibo cha kebo ili kuepuka mkazo kwenye lugi na kebo.
  • Usitumie skrubu za kujigonga ili kufunga vituo.
  • Kuunganisha nyaya za aina moja na kukimbia katika mwelekeo huo katika vikundi. Weka nyaya safi na moja kwa moja.
  • Cables zimefungwa kulingana na meza ifuatayo.
    Kipenyo cha Bundle ya Kebo (mm) Nafasi kati ya Vifungu (mm)
    10 80 hadi 150
    10 hadi 30 150 hadi 200
    30 200 hadi 300
  • Usifunge mafundo kwa nyaya au kebo
  • Sehemu za chuma za vizuizi vilivyobanwa na baridi, kama vile vivunja saketi za hewa, hazitafichuliwa nje ya vizuizi.

Orodha ya Ufungashaji

Jina Kiasi Kitengo Maoni
Mwenyeji 1 Weka  
Kuweka sahani 1 Kipande  
Kuweka bracket 1 Kipande  
Ungo wa M5x10 4 Kipande  
Ungo wa M6x20 2 Kipande  
Bolt ya upanuzi ya M6x50 4 Kipande  
Adapta isiyo na kioevu 2 Kipande Kwa kebo ya mtandao

na kamba ya umeme ya DC

Adapta isiyo na kioevu kwa

fiber ya macho

1 Kipande  
Bomba clamp 2 Kipande  
Cable ya kutuliza 1 Kipande  
Kuziba kuziba 3 Kipande Imesakinishwa awali
Dhamana ya Bidhaa

Mwongozo

1 Nakili  
TS-MWO2400C

Mwongozo wa Ufungaji wa Haraka wa Pointi ya Ufikiaji Bila Waya

 

1

 

Nakili

 

 

Nyaraka / Rasilimali

Technity SOLUTIONS TS-MWO2400C Series Wireless Access Point [pdf] Mwongozo wa Ufungaji
2ATAZ-MWO2400C, 2ATAZMWO2400C, mwo2400c, TS-MWO2400C Series Wireless Access Point, TS-MWO2400C Series, Wireless Access Point, Access Point

Marejeleo

Acha maoni

Barua pepe yako haitachapishwa. Sehemu zinazohitajika zimetiwa alama *