PIXSYS TCT101-3ABC Kipima saa Kipima Tachometer
UTANGULIZI
Thanks for choosing a Pixsys device. Techometer TCT101 allows to read the frequency (max 100KHz) of a signal from single or double (bidirectional encoder) input. 2 universal digital inputs are available (NPN/PNP/Potential free contact) for external commands like output activation or Hold/ Stop current visualization; one input it is also analogue in order to allow setpoint modification by external potentiometers.
DATA YA KIUFUNDI
- Joto la uendeshaji Operating temperature 0-40°C, humidity 35..95uR%
- Kuweka muhuri Front panel IP65 (with optional gasket) , Box IP30, Terminal blocks IP20
- Nyenzo PC ABS UL94V0 self-extinguishing
- Pembejeo za Dijitali 3PNP/NPN configurable as analogue for potentiometers. (max 28 Vdc in PNP mode)
- Outputs OUT 24V 2 relays 5A resistive charge 30mA(24Vac),40mA(24 Vdc),60mA (110…230Vac)
- Back-UP Rechargeable battery, approx. 7days autonomy
- Programu ya programu Labsoftview 2.6 au baadaye
- Ugavi wa Nguvu 24…230Vac/Vdc +/-15% 50/60Hz / 2W
UKUBWA NA KUFUNGA
- Soma kwa makini miongozo ya usalama na maagizo ya upangaji yaliyomo katika mwongozo huu kabla ya kutumia/kuunganisha kifaa.
- Tenganisha usambazaji wa umeme kabla ya kuendelea na mipangilio ya vifaa au nyaya za umeme.
- Watumishi waliohitimu pekee ndio wanaopaswa kuruhusiwa kutumia kifaa na/au kukihudumia na kwa mujibu wa data ya kiufundi na hali ya mazingira iliyoorodheshwa katika mwongozo huu.
- Usitupe zana za umeme pamoja na taka za nyumbani kwa kufuata Maelekezo ya Ulaya 2002/96/CE
DIAGRAM YA WIRANI
Potentiometer:
To modify Set1 or Set2 by an external potentiometer, follow the steps below:
- use potentiometers 5kOhm to 10kOhm
- Connect cursor to pin I3; a wrong connection may damage the potentiometer and lead to lock of the device.
- accuracy on input is max 1000 points, therefore set the parameters “Upper limit” and “Lower limit” with a max difference of 1000 units. (Ex.: LoS1 to 50,0 and uPS1 to 150,0 to modify time value related to Set1 between 50 and 150 seconds with steps of one tenth). Greater differences would make the less significant digit.
- To calibrate the scale of the potentiometer, enter the configuration mode and select: Hin.3 as Pot Fin.3 as Set1 or Set2 P.tAr as Enable Exit configuration mode and place potentiometer at minimum level and press key, then place potentiometer at max level and press the key: the device automatically exit the calibration procedure.
N.B.:Aswitch-off of the device would interrupt the calibration.
MEMORY CARD (optional)
Parameters and setpoint values can be copied from one device to another using the Memory car
Kuna njia mbili:
- With the device connected to the power supply insert the memory card when the controller is off
Kwenye onyesho la kuwezesha 1 inaonyesha na kuonyesha maonyesho 2(Only if the values stored on Memory Card are correct).
- Kwa kushinikiza
key display 2 shows
- Thibitisha kwa kutumia
ufunguo.
- The device loads the new data and starts again
With the controller disconnected from the power supply:
The memory card is equipped with an internal battery with a life of about 1000 uses. Insert the memory card and press the programming button. When writing the parameters, the LED turns red and on completing the procedure it changes to green. It is possible to repeat the procedure.
KUSASISHA KADI YA KUMBUKUMBU.
To update the memory card values, follow the procedure described in the first method, setting display 2 toso as not to load the parameters on the controller. Enter the configuration and change at least one parameter
- Exit configuration. Changes are saved automatically.
SETPOINT MODIFICATION
ORODHA YA VIGEZO
UJUMBE WA MAKOSA
Maswali Yanayoulizwa Mara Kwa Mara
Swali: Je, ninawezaje kusawazisha mizani ya potentiometer?
A: To calibrate the potentiometer scale, enter the configuration mode and select Hin.3 as Pot, Fin.3 as Set1 or Set2, and P.tAr as Enable. Exit configuration mode, set the potentiometer at the minimum level, and press a key.
Swali: Je, ni uwezo gani wa juu zaidi wa kusoma wa masafa ya kifaa?
J: Kifaa kinaweza kusoma masafa hadi 100KHz.
Nyaraka / Rasilimali
![]() |
PIXSYS TCT101-3ABC Kipima saa Kipima Tachometer [pdf] Mwongozo wa Mtumiaji TCT101-3ABC Kidhibiti Kipima Muda, TCT101-3ABC, Kipima Kipima Muda, Kipima Kipima Muda, Tachomita |