Sealey MM19

Sealey MM19 Digital Multimeter 7 Function User Manual

1. Introduktion

This manual provides instructions for the safe and effective use of the Sealey MM19 Digital Multimeter. The MM19 is a general-purpose multimeter designed for measuring various electrical parameters, including AC and DC voltage, DC current, resistance, audible continuity, and diode/transistor verification. Please read this manual thoroughly before operation and retain it for future reference.

2. Säkerhetsinformation

Always observe basic safety precautions when using electrical test equipment to reduce the risk of fire, electric shock, or personal injury. This device complies with IEC 1010 and CE CAT II safety standards.

  • Överskrid inte de maximala inmatningsgränserna for any function. Refer to the specifications section for details.
  • Applicera aldrig voltage to the meter when the rotary switch is set to Resistance (Ω), Diode, Continuity, or Current (A) functions.
  • Var försiktig när du arbetar med voltagöver 30V AC RMS, 42V toppspänning eller 60V DC. Dessa voltagdet utgör en chockrisk.
  • Se till att testkablarna är i gott skick, without cracked or broken insulation.
  • Always connect the common (COM) test lead first and disconnect it last.
  • Disconnect power to the circuit under test before measuring resistance or continuity.
  • Byt ut batteriet omedelbart when the low battery indicator appears to ensure accurate readings.

3. Produkt överview

The Sealey MM19 Digital Multimeter features a clear LCD display, a central rotary switch for function selection, and input jacks for test leads.

Sealey MM19 Digital Multimeter with test leads

The Sealey MM19 Digital Multimeter, shown with its yellow casing, large LCD display, rotary function switch, and red and black test leads connected to the input jacks.

Komponenter:

  • LCD-skärm: Large (46 x 25mm) digital display for reading measurements.
  • Strömbrytare: Används för att välja önskad mätfunktion och mätområde.
  • VΩmA Input Jack: För voltage, resistance, and current measurements up to 200mA.
  • 10ADC Input Jack: For high current measurements up to 10A DC (unfused).
  • COM-ingång: Gemensam (negativ) ingång för alla mätningar.
  • hFE-uttag: For transistor (NPN/PNP) testing.
  • Testledningar: Röda (positiva) och svarta (negativa) ledningar för anslutning till kretsar.

4. Inställning

4.1. Batteriinstallation

The Sealey MM19 Multimeter requires a 9V battery for operation. If the display does not illuminate or shows a low battery indicator, the battery needs to be installed or replaced.

  1. Se till att multimetern är AVSTÄNGD.
  2. Leta reda på batterifackets lock på baksidan av enheten.
  3. Ta bort skruven/skruvarna som håller fast locket och lyft försiktigt bort det.
  4. Anslut ett nytt 9V-batteri till batteriklämmorna och observera rätt polaritet.
  5. Place the battery inside the compartment and replace the cover, securing it with the screw(s).

4.2. Anslutning av testkablar

The multimeter is supplied with a pair of test leads (red and black).

  • Sätt in svart testsladd in i COM (Gemensam) ingång.
  • För de flesta mätningar (volymtage, resistance, low current), insert the röd testsladd in i VΩmA ingångsjack.
  • For high DC current measurements (up to 10A), insert the röd testsladd in i 10 ADC ingångsjack.

5. Bruksanvisning

To operate the multimeter, select the desired function and range using the rotary switch.

5.1. Mätning av likströmsvolymtage (DCV)

  1. Insert the red lead into the VΩmA jack and the black lead into the COM jack.
  2. Set the rotary switch to the desired DCV range (e.g., 200m, 2000m, 20, 200, 1000). Start with the highest range if the voltage är okänd.
  3. Anslut testkablarna över komponenten eller kretsen som ska mätas.
  4. Läs voltage-värdet på LCD-skärmen.

5.2. Mätning av AC Voltage (ACV)

  1. Insert the red lead into the VΩmA jack and the black lead into the COM jack.
  2. Set the rotary switch to the desired ACV range (e.g., 200, 750). Start with the highest range if the voltage är okänd.
  3. Anslut testkablarna över komponenten eller kretsen som ska mätas.
  4. Läs voltage-värdet på LCD-skärmen.

5.3. Mätning av likström (DCA)

  1. For currents up to 200mA: Insert the red lead into the VΩmA jack and the black lead into the COM jack.
  2. For currents up to 10A: Insert the red lead into the 10ADC jack and the black lead into the COM jack.
  3. Set the rotary switch to the desired DCA range (e.g., 200μ, 2000μ, 20m, 200m, 10A). Start with the highest range if the current is unknown.
  4. Stäng av strömmen till kretsen. Öppna kretsen där strömmen ska mätas.
  5. Anslut multimetern i serie med kretsen.
  6. Slå på strömmen till kretsen och läs av strömvärdet på LCD-displayen.

5.4. Mätning av resistans (Ω)

  1. Insert the red lead into the VΩmA jack and the black lead into the COM jack.
  2. Set the rotary switch to the desired Resistance (Ω) range (e.g., 200, 2000, 20k, 200k, 2000k).
  3. Se till att kretsen som testas är spänningslös.
  4. Anslut testkablarna över den komponent som ska mätas.
  5. Läs av resistansvärdet på LCD-displayen.

5.5. Hörbar kontinuitetstest

  1. Insert the red lead into the VΩmA jack and the black lead into the COM jack.
  2. Set the rotary switch to the continuity symbol (speaker icon).
  3. Se till att kretsen som testas är spänningslös.
  4. Anslut testkablarna över komponenten eller kabeln.
  5. If continuity exists (low resistance), the meter will emit an audible tone. The display will show the resistance value.

5.6. Diode/Transistor Verification Mode (hFE)

  1. Insert the red lead into the VΩmA jack and the black lead into the COM jack for diode testing.
  2. Ställ in vridomkopplaren på diodsymbolen.
  3. Anslut den röda ledningen till anoden och den svarta ledningen till katoden på dioden. Displayen visar framåtvolymen.tage-droppet. Vänd ledningarna; displayen ska visa 'OL' (öppen loop) för en fungerande diod.
  4. For transistor hFE measurement, insert the transistor leads (Emitter, Base, Collector) into the appropriate sockets (E, B, C) in the hFE test socket, ensuring correct NPN or PNP type selection.
  5. Läs av hFE-värdet på LCD-displayen.

6. Underhåll

6.1. Städning

Torka av mätaren casing med annonsamp trasa och ett milt rengöringsmedel. Använd inte slipmedel eller lösningsmedel. Se till att mätaren är helt torr före användning.

6.2. Batteribyte

Refer to Section 4.1 for battery installation instructions. Replace the 9V battery when the low battery indicator appears on the display to maintain measurement accuracy.

7. Felsökning

  • Ingen skärm: Check battery installation and ensure the battery has sufficient charge.
  • 'OL' or '1' on Display: This usually indicates an over-range condition or an open circuit. Select a higher range or check connections.
  • Felaktiga avläsningar: Ensure the correct function and range are selected. Check test lead connections and battery condition.
  • Ingen kontinuitetston: Verify the circuit is de-energized and the leads are making good contact.

8. Specifikationer

ParameterVärde
StämplaSealey
ModellnummerMM19
StrömkällaBatteridriven (9V)
VisaDigital LCD (46 x 25mm)
DC Voltage (DCV)200 mV, 2000 mV, 20 V, 200 V, 1000 V
AC Voltage (ACV)200V, 750V
DC Current (DCA)200µA, 2000µA, 20mA, 200mA, 10A
Motstånd (Ω)200Ω, 2000Ω, 20kΩ, 200kΩ, 2000kΩ
KontinuitetAudible tone below approx. 30Ω
DiodtestForward voltage drop display
TransistortesthFE (NPN/PNP)
SäkerhetsbetygCE CAT II, IEC 1010
Mått (L x B x H)1.93 x 4.21 x 6.06 tum
Objektets vikt9.5 ounces (0.27 kilogram)

9. Garanti och support

For warranty information or technical support, please refer to the documentation provided with your purchase or contact Sealey customer service directly. Keep your proof of purchase for any warranty claims.

Relaterade dokument - MM19

Preview Sealey MM19.V3 7-funktions digital multimeter användarmanual
Omfattande användarmanual för Sealey MM19.V3 7-funktions digital multimeter, med detaljerade säkerhetsinstruktioner, specifikationer, funktioner och drift för AC/DC-spänning.tage, likström, resistans, kontinuitet och transistormätningar.
Preview Sealey MM102 Professionell digital multimeter med automatisk avståndsmätning Användarmanual och instruktioner
Detaljerad användarmanual och bruksanvisning för Sealey MM102 Professional Auto-Ranging digital multimeter, inklusive säkerhetsåtgärder, specifikationer och underhållsguider.
Preview Sealey TM102 8-funktions professionell digital multimeter med automatiskt områdesavstånd - användarmanual
Omfattande användarmanual för Sealey TM102 8-funktions professionell digital multimeter med automatiskt områdesavstånd. Innehåller säkerhetsinstruktioner, specifikationer, bruksanvisning och underhållsprocedurer.
Preview Sealey TA101 12-funktioners digitala fordonsanalysator användarmanual
Omfattande användarmanual för Sealey TA101 12-funktions digital fordonsanalysator. Beskriver säkerhetsåtgärder, tekniska specifikationer, driftsprocedurer för olika mätningar, underhåll och felsökning.
Preview Sealey 6-24V Auto Probe Plus PPX.V4 Användarmanual
Omfattande instruktioner för Sealey 6-24V Auto Probe Plus (modellnr PPX.V4), som täcker säkerhet, funktioner, drift, testning och felsökning för fordonselektriska system.
Preview Sealey 1050CXLE v3 Domkraft Hydraulolja Säkerhetsdatablad
Säkerhetsdatablad för Sealey 1050CXLE v3 Domkraft 2 Tonne Low Profile Hydraulolja för kort chassis, med detaljerad information om produktidentifiering, faror, första hjälpen, brandbekämpning, hantering, förvaring, fysikaliska egenskaper och avfallshantering.