AXESS ELITE plus 120V Power Management System
“
Specifications:
- Model: ELITE SX-AEP-209
- AC Outlets:
- Outlet 1-2: ~120V, 16A each
- Outlet 3-8: ~120V, 12A each (total load not to exceed 16A)
Product Usage Instructions:
Main Shutdown Self-Test:
- Ensure all connected devices are powered off.
- Perform a mains shutdown self-test following the user manual
instructions.
Connections:
Refer to the user manual for detailed connection instructions.
Rear terminal block connections include contact closure,
temperature/humidity, auxiliary relay A and B.
Web Browser Access:
Access the device via a web browser for configuration and
monitoring. Follow the user manual for detailed steps on web
browser access.
Additional Information:
For any technical support, contact 800-645-9721 or visit
surgex.com.
FAQ:
Q: How do I reset the device?
A: Use the RESET button on the device to perform a reset. Refer
to the user manual for specific reset instructions.
Q: Can I exceed the maximum load on outlets 3-8?
A: No, ensure that the total load on outlets 3-8 does not exceed
16A to prevent damage to the device.
“`
ELIT E
QUICK START GUIDE
1
MAINS SHUTDOWN SELF-TEST
AB
1
2
3
4
5
6
7
8
9
AUX, RELAYS
OUTLETS
ELITE SX-AEP-209
AC OUTLET 9 ~120V, 12A ~120V, 12A FOR RCPT 3-8 16A MAX LOAD TOTAL
~120V, 16A FOR RCPT 1-2
1
~120V, 16A
3
2
3
4
5
1
6
7
8
CC
T/H
NO NC C NO NC C
AUX A
AUX B
IOIOI
USB
RESET
SW HW
2
1. Powered Equipment · Connect appropriately rated devices to the receptacles on the rear panel
· Ensure the total load does not exceed Axess Elite+’s rated maximum
CONNECTIONS:
2. Network · Use the supplied ethernet cable or other suitable Cat 5 cabling (supports 10/100 ethernet)
3. Power Mains · Plug the power cord into the appropriately rated receptacle
OPTIONAL CONNECTIONS:
1. Serial Port · 9-pin D-subminiature connector for RS-232 serial control · Default serial parameters are 115200 bps, 8 data, no parity, 1 stop bit (115200,8, n,1)
2. Temperature Sensor · Connect red wire to pin 1, SDA (Green/Blue) to pin 2, SCL (Yellow/White) to pin 3 and black wire to pin 4 of the second terminal block
3. Contact Closure Input · Connect contact closure control input to the 2 pins of the first terminal block
4. Auxiliary Relay Outputs · Two auxiliary relay outputs at the third (Aux Relay A) and fourth (Aux Relay B) terminal blocks
5. Rear Terminal Block Connections
Contact Closure CC1 CC2
Temperature/Humidity +5V SDA SCK GND
Auxiliary Relay A
NO
NC COM
Auxiliary Relay B
NO
NC COM
WEB BROWSER ACCESS:
1. Factory Default IP Address · DHCP Assigned
2. Factory Default Security Credentials · Username: admin · Password: Adm1nXXXXXX Where XXXXXX are the last six characters of the MAC address in ALL CAPS
3. Access Setup · Ensure the PC is on the same local network · Enter the IP address in a web browser · Use credentials for full access (user credentials for power control only)
For more detailed instructions please refer to the user manual.
©2025 AMETEK SurgeX | B01-00013 (REV A)
Technical Support: 800-645-9721 | surgex.com