SuperPost FRP Composite H Post
Product Information
Specifications
- Materials and workmanship to comply with relevant Australian
standards - Concrete strength: Footing = N20, Concrete Sleeper = N40
- Maximum aggregate size: 20mm
- Reinforcement grade: ‘N’ denotes Grade 500 deformed bar, ‘R’
denotes Grade 230 plain round bar - Fencing bracket designed for full shielding with specific
properties surrounding the fence
Product Usage Instructions
Retaining Wall
- Ensure surcharge live loads do not exceed 2.5 kPa
- Engage an RPEQ geotechnical engineer to assess the design
against global slip - Prepare the ground by removing topsoil containing organic
material before foundation - Avoid positioning any structure on top of the wall within its
height
Concrete
- Construct concrete work in accordance with AS3600
standards - Avoid adding water to concrete on-site
- Ensure surface finishes comply with AS3600 standards
- Follow clear cover requirements for reinforcement as per
AS3600
Fence Bracket
Install fencing bracket with consideration for full shielding
and specific property surroundings as per design assumptions.
FAQ
Q: Can I use a different concrete strength than specified?
A: It is recommended to use the specified concrete strengths for
optimal performance and safety.
Q: Do I need to engage a geotechnical engineer for all
retaining wall installations?
A: It is advisable to engage a geotechnical engineer, especially
for assessing global stability.
GENERAL NOTES
1. THESE DRAWINGS ARE TO BE READ IN CONJUNCTION WITH ALL ARCHITECTURAL AND OTHER CONSULTANTS DRAWINGS. ANY SET OUT DIMENSIONS AND LEVELS SHOWN ON DRAWINGS ARE TO BE VERIFED PRIOR TO CONSTRUCTION.
2. ALL MATERIALS AND WORKMANSHIP TO BE IN ACCORDANCE WITH THE RELEVANT CURRENT AUSTRALIAN STANDARDS AND WITH THE LATEST BUILDING CODE OF AUSTRALIA.
3. DO NOT SCALE STRUCTURAL DRAWINGS TO OBTAIN DIMENSIONS. IF IN DOUBT ASK! 4. ALL DIMENSIONS ARE IN MM UNLESS STATED OTHERWISE. ALL LEVELS ARE SHOWN IN METERS. LEVELS SHOWN
ON THESE DRAWINGS ARE FOR THE PURPOSE OF ASSISTING STRUCTURAL DOCUMENTATION AND SHOULD NOT BE USED FOR CONSTRUCTION UNLESS ADVISED BY NOVUS ENGINEERING. ALWAYS CROSS REFERENCE LEVELS WITH THE LATEST ARCHITECTURAL DRAWINGS FOR RL’S. 5. THE BUILDER IS RESPONSIBLE FOR THE ADEQUACY OFF ALL TEMPORARY WORKS INCLUDING PROPPING AND BRACING. WHERE NECCESARY THE BUILDER SHALL ENGAGE THE SERVICES OF A STRUCTURAL ENGINEER TO DESIGN AND CERTIFY TEMPORARY WORKS. 6. THE METHOD OF CONSTRUCTION AND HEALTH AND SAFETY DURING CONSTRUCTION ARE THE RESPONSIBILTY OF THE BUILDER. IF STRUCTURAL ELEMENTS POSE RISK OR DIFFICULTY WHEN CONSTRUCTING, ADVICE SHALL BE SOUGHT FROM THE STRUCTURAL ENGINEER. 7. ALL MEMEBERS MENTIONED ON THESE DRAWINGS, ARE SUPERSLEEPER PRODUCTS. UNDER NO CIRCUMSTANCES SHALL THE DETAILS BE USED WITH OTHER PRODUCTS WITHOUT SUPERSLEEPER AUTHORISATION. 8. ANY DISCREPANCY WITH MEMBER SIZES, FIXINGS,COMPONENTS OR OMISSIONS SHALL BE REFERRED TO THE SUPERSLEEPER. UNDER NO CIRCUMSTANCES SHALL ASSUMPTIONS BE MADE WHETHER FOR PRICING, CONSTRUCTION OR OTHER SERVICE.
RETAINING WALL
1. SURCHARGE LIVE LOADS: 2.5 kPa. NO ADDITIONAL IMPOSED LOADS OF ANY STRUCTURES WITHIN THE RETAINING WALL ZONE OF INFLUENCE.
2. THIS DESIGN HAS NOT BEEN VERIFIED FOR GLOBAL STABILITY. AS PER GOOD WORKING PRACTICE AND IN ACCORDANCE WITH AS4678, AN RPEQ GEOTECHNICAL ENGINEER MUST BE ENGAGED BY THE CLIENT TO ASSESS THE DESIGN AGAINST GLOBAL SLIP.
3. BUILDER TO PREPARE GROUND FOR FOUNDATION BY REMOVAL OF ANY TOPSOIL CONTAINING ORGANIC MATERIAL. 4. UNDER NO CIRCUMSTANCES SHALL ANY STRUCTURE BE POSITIONED ON TOP OF THE WALL WITHIN HEIGHT OF THE
WALL, REGARDLESS WHETHER THE STRUCTURE IS ON SCREW PILES. 5. THE FOUNDATION DEPTHS HAVE BEEN DEVELOPED USING TYPICAL SOIL PARAMETERS. FOUNDATION MATERIAL
SHALL BE CONFIRMED AND APPROVED PRIOR TO POURING OF CONCRETE BY A COMPETENT PERSONAL AND DOCUMENTED
CONCRETE
1. CONCRETE WORK SHALL BE CONSTRUCTED IN ACCORDANCE WITH AS3600. 2. CONCRETE STRENGTH: FOOTING = N20, CONCRETE SLEEPER = N40 AT 28 DAYS SLUMP TO BE 80mm AND MAXIMUM
AGGREGATE SIZE 20mm. 3. DO NOT ADD WATER TO CONCRETE ON SITE. 4. SURFACE FINISHES TO BE IN ACCORDANCE WITH AS3600. 5. CLEAR COVER TO REINF. TO AS3600 AND UNLESS NOTED OTHERWISE TO BE: SLAB ON GROUND 30mm TOP COVER,
FOOTINGS 50mm COVER 6. REINFORCEMENT TO AS1302, ‘N’ DENOTES GRADE 500 DEFORMED BAR, ‘R’ DENOTES GRADE 230 PLAIN ROUND BAR,
‘L’ DENOTES HARD DRAWN WIRE FABRIC TO AS1304. MIN. LAP OF REINFORCEMENT UNLESS NOTED OTHERWISE TO BE 50*REO DIA. (eg. N12 LAP = 12*50 = 600mm) AND 200mm FOR FABRIC. 7. CONCRETE SURFACES TO BE CURED BY AN APPROVED METHOD FOR SEVEN DAYS IMMEDIATELY AFTER THE CONCRETE IS HARD. 8. WHEN BUILDING OVER OR NEAR SEWER OR STORMWATER SERVICES, PLEASE NOTE THE FOLLOWING A. OBTAIN APPROVAL FROM LOCAL COUNCIL AUTHORITY PRIOR TO ANY CONSTRUCTION B. CONFIRM SERVICES INVERT LEVEL AND AND ALIGNMENT PRIOR TO EXCAVATION .
FENCE BRACKET
FENCING BRACKET DESIGNED TAKING INTO ACCOUNT FULL SHEILDING WITH AT LEAST 2 PROPERTIES SURROUNDING THE FENCE (MS = 0.85), IMPORTANCE LVL 1, REGION B, HAS BEEN ASSUMED. Mt = 1.0, CAT = 3.0. IF THESE ARE TO CHANGE PLEASE NOTIFY SUPERSLEEPER.
WALL HEIGHT ‘H’
400
600 800 1000
SINGLE TIER RETAINING WALL – STIFF CLAY FOUNDING MATERIAL 5kPa
FOOTING DEPTH FOOTING DEPTH FOOTING ‘D’ (NO FENCE) ‘D’ (WITH FENCE) SPACING ‘S’
INTERMEDIATE POST
PILE DIA. ‘PD’
600
800
2400
120H SUPERPOST
300
800
1000
2400
120H SUPERPOST
450
1000
1200
2000
120H SUPERPOST
450
1200
1400
2000
120H SUPERPOST
450
WALL HEIGHT ‘H’
400
600 800 1000
SINGLE TIER RETAINING WALL – WEATHERED ROCK FOUNDING MATERIAL – 5kPa
FOOTING DEPTH FOOTING DEPTH FOOTING ‘D’ (NO FENCE) ‘D’ (WITH FENCE) SPACING ‘S’
INTERMEDIATE POST
PILE DIA. ‘PD’
600
600
2400
120H SUPERPOST
300
600
600
2400
120H SUPERPOST
450
800
1000
2000
120H SUPERPOST
450
1000
1200
2000
120H SUPERPOST
450
WALL HEIGHT ‘H’
400
600 800 1000
SINGLE TIER RETAINING WALL – SAND – FOUNDING MATERIAL 5kPa
FOOTING DEPTH FOOTING DEPTH FOOTING ‘D’ (NO FENCE) ‘D’ (WITH FENCE) SPACING ‘S’
INTERMEDIATE POST
PILE DIA. ‘PD’
900
1000
2400
120H SUPERPOST
300
1100
1200
2400
120H SUPERPOST
450
1300
1400
2000
120H SUPERPOST
450
1500
1600
2000
180H SUPERPOST
450
END POST
120C SUPERPOST 120C SUPERPOST 120C SUPERPOST 120C SUPERPOST
END POST
120C SUPERPOST 120C SUPERPOST 120C SUPERPOST 120C SUPERPOST
END POST
120C SUPERPOST 120C SUPERPOST 120C SUPERPOST 120C SUPERPOST
GEOTECHNICAL PARAMETERS
UNIT WEIGHT
RETAINED/FOUNDING: STIFF CLAY
19kN/m3
INTERNAL ANGLE OF FRICTION DRAINED COHESION
26 5 kPa
GEOTECHNICAL PARAMETERS WR
RETAINED/FOUNDING: WEATHERED ROCK
UNIT WEIGHT
22kN/m3
INTERNAL ANGLE OF FRICTION DRAINED COHESION
30 10 kPa
GEOTECHNICAL PARAMETERS SAND
RETAINED/FOUNDING: SAND
UNIT WEIGHT
19kN/m3
INTERNAL ANGLE OF FRICTION DRAINED COHESION
33 0 kPa
23/06/2025 UPDATED
DATE
DESCRIPTION
GB 2
BY REV
SUPER SLEEPER
Composite Retaining Wall
DRAWING TITLE
GENERAL NOTES
01 2
‘H’ SUPERPOST
B-
SUPERSLEEPER
0–2-
OPTIONAL CAP
IMPERVIOUS CATH DRAIN TO STORM WATER ENGINEER DESIGN 12 02
SEE TABLE
A ELEVATION
02 SCALE 1 : 25
B
02
2
02
02
A
‘C’ SUPERPOST
9
PIERS
02
B SEC -B
02 SCALE 1 : 20
4
20mm MIN. CRUSHED ROCK DRAINAGE FILL MATERIAL. 200mm THK
MIN. AROUND DRAINAGE PIPE AND EXTENDING UP THE WALL AS
02
SHOWN.
POST
200 MIN.
1 FLOOR PLAN
8 02
SCALE 1 : 25
OPTIONAL CAP
NON-WOVEN GEOTEXTILE FILTER FABRIC TO WRAP AROUND DRAINAGE MATERIAL
LIVE SURCHARGE AS PER AS4678-2002
1000
20
200
SLEEPERS
RETAINED SOIL
OPTIONAL IMPERVIOUS CATCHMENT DRAIN TO STORM WATER ENGINEER DESIGN
20mm MIN. CRUSHED ROCK DRAINAGE FILL MATERIAL. 200mm THK MIN. AROUND DRAINAGE PIPE AND EXTENDING UP THE WALL AS SHOWN. OR USE ALTERNATIVE SUPERDRAIN TO REMOVE FREE DRAINING GRAVEL AND GEOFABRIC
SEE TABLE
SUPERWEDGE
Ø 65mm PIPE CONNECT TO THE NEAREST
SSL
STORMWATER OUTLET.
7 02
SUPERSLEEPER
PIER
SEE TABLE
2 FLOOR PLAN DETAIL
02 SCALE 1 : 20
OPTIONAL CAP
SUPERSLEEPER
SUPERSLEEPER
‘H’ SUPERPOST COMPOSITE MATERIAL / STEEL POST
20mm MIN. CRUSHED ROCK DRAINAGE FILL MATERIAL. 200mm THK MIN. AROUND DRAINAGE PIPE AND EXTENDING UP THE WALL AS SHOWN. OR USE ALTERNATIVE SUPERDRAIN TO REMOVE FREE DRAINING GRAVEL AND GEOFABRIC
3 3D SECTION
SCALE
10 MIN.
SUPERSLEEPER ‘C’ SUPERPOST
SUPERSLEEPER ‘H’ SUPERPOST
PIER DEPTH IN ACCORDANCE WITH ENGINEERS DESIGN
‘H’ SUPERPOST
‘C’ SUPERPOST
SUPER WEDGE
10 MIN.
SUPERWEDGE
SUPERSUPPORT CONCRETE BORED PIER
7 ‘C’ SUPERPOST DETAIL
02 SCALE 1 : 5
8 ‘H’ SUPERPOST DETAIL
02 SCALE 1 : 5
100 MIN.
4 SECTION B
02 SCALE 1 : 20
EMBDEDMENT SOIL POST
5 3D DETAIL REVERSED
SCALE
‘H’ SUPERPOST
6 3D DETAIL
SCALE
FENCE POST
DETAIL USED WHERE DOUBLE SLEEPERS ARE REQUIRED FOR LOAD SHARING
SUPERWEDGE NOT SHOWN FOR CLARITY
SUPERSLEEPER PIER
SUPERPOST SUPERWEDGE SUPERSUPPORT
SUPERSUPPORT SLIDES ON FROM SIZE
9 SUPERSUPPORT DETAIL
02 SCALE 1 : 5
10 BASE FIXING – 3D DETAIL
SCALE
23/06/2025 UPDATED
DATE
DESCRIPTION
GB 2
BY REV
SUPER SLEEPER
Composite Retaining Wall
OPTIONAL CAP
SUPERSLEEPER TONGUE AND GROOVE, FEMALE DOWN
SUPER BRACKET, USE 4No. M12 NYLOC NUT AND BUTTON HEAD BOLT
OPTIONAL CAP SUPER WEDGE
SUPERSLEEPER
SAY 100×100 FIXED AT 3RD POINTS NOMINAL PACK
SUPERSUPPORT
PIER
CONCRETE BORED PIER SUPER SLEEPER
SUPER POST
11 SUPERBRACKET DETAIL 3D
SCALE
SUPER POST
12 SUPERSUPPORT UNDER SUPERCAP
02 SCALE 1 : 5
DRAWING TITLE
13 SUPERSUPPORT DOUBLE
SCALE 1 : 5
SLEEPER WALLS PLANS, SECTIONS AND DETAILS
02 2
Documents / Resources
![]() |
Super Sleeper SuperPost FRP Composite H Post [pdf] User Guide SuperPost, SuperPost FRP Composite H Post, SuperPost, FRP Composite H Post, H Post |