STELPRO logo

STELPRO ST252NP Non-Programmable Electronic Thermostat for Baseboards and Convectors Owner’sSTELPRO ST252NP Non Programmable Electronic Thermostat for Baseboards and Convectors Owner's product

NON-PROGRAMMABLE ELECTRONIC THERMOSTAT FOR BASEBOARDS AND CONVECTORS

IMPORTANT INSTRUCTIONS

THE THERMOSTAT MUST BE INSTALLED BY A CERTIFIED ELECTRICIAN.
Connect the thermostat to a 120 to 240 VAC power source ONLY and comply with load limits.

WARNING – HIGH VOLTAGE
Turn off the power supply before installation and main-tenance. Leave at least 12 in. (30 cm) clearance around the thermostat to ensure that it is properly vented.
SAVE THESE INSTRUCTIONS

TECHNICAL SPECIFICATIONS

VOLTAGE AND LOAD
PRODUCT CODE SUPPLY VOLTAGE LOAD AT 120 V LOAD AT 240 V
  VOLTS WATTS WATTS
ST252NP  

120-240

150-1250 300-2500
ST302NP 150-1500 300-3000
ST402NP 150-2000 300-4000

STELPRO ST252NP Non Programmable Electronic Thermostat for Baseboards and Convectors Owner's fig 1

BEFORE YOU GET STARTED

  • The box contains one (1) thermostat with mounting plate, two (2) mounting screws, two (2) twist-on wire connectors and one (1) owner’s manual.
  • To install this thermostat, you will need a #2 Phillips screw-driver.
  • Install your thermostat about 5 ft (1.5 m) from the floor on an inside wall facing the heating system.

INSTALLATION

WARNING
Turn off the power supply.

  1. Loosen the screw [A] at the top of the thermostat [B] without removing it.
  2. Separate the mounting plate [C] from the thermostat. Pull the top of the plate and rotate it as shown.
  3. Take the power wires [D] out of the junction box [E] and run them through the large opening in the center of the mounting plate [F].
  4. Using the two (2) mounting screws provided [G], attach the thermostat mounting plate to the junction box [E]. The plate can be centered on the junction box or shifted to the left or right.STELPRO ST252NP Non Programmable Electronic Thermostat for Baseboards and Convectors Owner's fig 2

CONNECT THE POWER SUPPLY WIRES

  1. Complete the thermostat’s electrical connection according to the diagram below. Tighten the wires securely in the supplied wire connectors.
  2. Push the wires and connectors into the electrical box.STELPRO ST252NP Non Programmable Electronic Thermostat for Baseboards and Convectors Owner's fig 3
    NOTE: If the electrical wires are aluminum, use CO/ALR connectors instead (not supplied).

ATTACH THE THERMOSTAT

  1. Using the alignment guide, hook the bottom [A] of the thermostat into the bottom of the plate. Be sure not to jam the wires between the thermostat and mounting plate.
  2. Rotate the thermostat upwards [B] and attach it on the top hook of the mounting plate.
  3. Tighten the screw at the top of the thermostat [C] to hold it in place securely.
  4. Restore the power at the circuit breaker.STELPRO ST252NP Non Programmable Electronic Thermostat for Baseboards and Convectors Owner's fig 4

NOTE: If you need to remove the thermostat, follow step 1 in section 1, then use a straight screwdriver to unhook it from the top of the mounting plate.

INTERFACE
This is a non-programmable thermostat. The temperature setpoint remains constant unless you change it.STELPRO ST252NP Non Programmable Electronic Thermostat for Baseboards and Convectors Owner's fig 5
Touch the keypad once to activate the backlight, then you can make changes.

INITIAL SETTINGS

To begin with, follow the on-screen instructions to adjust your thermostat’s settings. Press or  to change your selection and to confirm.

  1. Temperature format: °C / °F (Celsius / Fahrenheit)
  2. ECO mode setpoint temperature (5 °C to 30 °C / 41 °F to 86 °F). By default, the ECO mode setpoint is 17 °C / 63 °F.

Your heating needs may vary according to the season and even the time of day. To meet your needs, this ther-mostat is equipped with two distinct modes: ECO and COMFORT. You can switch from one mode to another by simply pressing  . ECO mode saves you money by providing a more energy-efficient setpoint temperature when you’re sleeping or away from home.
YOUR THERMOSTAT IS NOW READY TO USE!

FEATURES

KEY FEATURES

  1. Press or once to lower or raise the setpoint temperature by 0.5 °C / 1 °F. The setpoint temperature will remain at this value until it is changed. Note: If you change the setpoint temperature while in ECO mode, the thermostat
    will switch to COMFORT mode.
  2. Press once to switch from ECO mode to COMFORT mode and vice versa.

ADVANCED MENU ACCESS AND USE

  1. Press and hold for three (3) seconds to access the thermostat’s advanced menus.
  2. Press or to change your selection.
  3. Press to confirm your selection and proceed to the next menu.
  4. Press and hold for three (3) seconds to exit the advanced menus.

ADVANCED MENUS LIST

  • Menu 10 – Temperature format: °C / °F (Celsius / Fahrenheit)
  • Menu 20 – ECO mode setpoint temperature (5 °C to 30 °C / 41 °F to 86 °F). By default, the ECO mode setpoint is 17 °C / 63 °F.
  • Menu 30 – Keypad lock: ON / OFF (Lock / Unlock keypad)
  • dEF – Reset thermostat to default values: N / Y (No / Yes)

Documents / Resources

STELPRO ST252NP Non Programmable Electronic Thermostat for Baseboards and Convectors [pdf] Owner's Manual
ST302NP, ST402NP, ST252NP, Non Programmable Electronic Thermostat for Baseboards and Convectors, ST252NP Non Programmable Electronic Thermostat for Baseboards and Convectors