Specifications
- Amplifier Output: Rev 1.1
- Module Gain Adjustment: Shipped configured for a gain of 21.5dB
Product Usage Instructions
Module Gain Adjustment:
The gain of the module can be adjusted by manipulating jumpers J2 and J3. The following table outlines the gain configurations:
Gain | J2 Setting | J3 Setting |
---|---|---|
21.5dB | Installed | Installed |
16.8dB | Removed | Removed |
NOTE: Ensure that both jumpers are either installed or removed. Do not operate the module with only one jumper installed.
NOTES:
- Due to the bridged amplifier design, both speaker terminals (HL1 & HL2) are hot when the amplifier is on.
- Do not connect either output to ground (GND)
- Do not power up the amp without a load or speaker connected.
- Do not plug a live power supply into the amp.
- Not compatible with electrostatic speakers. Please use our Ultra models in this scenario.
To turn the amp on:
- Connect speakers
- Connect Input (XLR)
- PPlugpower supply into the amp (power supply must be off)
- Turn on the power supply
To turn the amp off:
- Turn off the power supply and allow enough time for the capacitors to discharge.
- Remove connections
Amplifier Output:
- The amplifier outputs are HL1 and HL2.
Amplifier Input:
- The amplifier input is the XLR connector or X3
Mounting Holes:
- The module has 5 mounting holes that work with either M3 or 4-40 hardware
- All mounting holes are connected to the module ground
- The module should be mounted in a vented enclosure so ambient temperatures do not exceed 40 °C.
Power Supply Connection:
- The power supply should be 45.6V minimum, 58.8V maximum, with a minimum output power of 250W.
- Recommend Power Supplies:
- Recom-Power RACM230-54SG (one per amp module)
- XP-Power GCS350PS56 (one per amp module)
- CUI Inc SDI250-56-U-P219 (one per amp module)
- CUI Inc SDI300G-56-U-P219 (one per amp module)
- If using a power supply with more than 300W output power, it is highly recommended to put a fuse inline between the power supply and amplifier.
- Recommend Power Supplies:
- The mating plug is Molex / 39-01-2060, with the following pinout:
Module Gain Adjustment
The module is shipped configured for a gain of 21.5 dBB.
The gain can be adjusted by jumpers J2 and J3. See the table below for acceptable configurations
Gain | J2 Setting | J3 Setting |
21.5dB | Installed | Installed |
16.8dB | Removed | Removed |
NOTE: Both jumpers must be installed or removed. Do not operate the module with only one jumper installed.
FAQs
- Q: What should I do if I need a gain different from 21.5dB or 16.8dB?
A: For gains other than 21.5dB or 16.8dB, please refer to the product manual for detailed instructions on adjusting the jumpers for custom gain settings. - Q: Is it safe to operate the module with just one jumper installed?
A: No, it is not safe to operate the module with only one jumper installed. Both jumpers must be either installed or removed to ensure proper functionality and performance.