CISCO C8500 Edge Platforms Data Router User Guide

C8500 Edge Platforms Data Router

Litlhaloso

  • Product Name: Router Factory Reset
  • Supported Releases: Cisco IOS XE Bengaluru 17.5.1 and
    hamorao
  • Feature: Factory Reset for restoring device to a fully
    functional state
  • Command Name: factory-reset all secure

Litaelo tsa Tšebeliso ea Sehlahisoa

Factory Reset Feature Information

The Factory Reset tšobotsi lumella u ho sireletsa kapa tsosolosa a
router to an earlier, fully functional state.

How Factory Reset Works

Factory Reset e hlakola ts'ebetso ea hajoale le ho qala
configuration information on a device, resetting it to a
fully-functional state. It uses the command factory-reset all to
backup existing configuration and perform the reset.

The duration of the factory reset process varies based on the
router’s storage size, ranging from 30 minutes to 3 hours.

Sireletseha Factory Reset

Starting from Cisco IOS XE Bengaluru 17.6 release, you can use
the factory-reset all secure command to securely clear files bolokoa
in bootflash memory.

Software and Hardware Support

The factory reset process is supported by specific software and
hardware configurations. Refer to the manual for details.

Litlhoko tse hlokahalang bakeng sa ho etsa Factory Reset

Ensure you have the necessary permissions and access to perform
a factory reset. Back up critical data before proceeding.

Restrictions for Performing a Factory Reset

Understand the limitations and restrictions associated with
performing a factory reset before initiating the process.

When to Perform Factory Reset

You may consider a factory reset when troubleshooting persistent
issues or restoring the device to a known working state.

Mokhoa oa ho etsa Reset ea Fektheri

Refer to Table 2 to determine which information will be deleted
and retained during the reset. Follow the appropriate command based
ka litlhoko tsa hau.

  1. Step 1: Log in to a Cisco Catalyst 8500 or 8500L device.

FAQ (Lipotso Tse Botsoang Hangata)

Q: What data is erased during Factory Reset?

A: Data erased includes NVRAM data, logs, credentials, ROMMON
variables, writeable file systems, and personal data.

Q: How long does the Factory Reset process take?

A: The duration varies based on the router’s storage size,
ranging from 30 minutes to 3 hours.

Q: Can I retain specific data during Factory Reset?

A: Yes, you can use specific commands like factory-reset
keep-licensing-info to retain certain data during the reset
tshebetso.

"`

Hlahisa Fektheri bocha

This chapter describes Factory Reset feature and how it can be used to protect or restore a router to an earlier, fully functional state.
· Feature Information for Factory Reset, on page 1 · Information About Factory Reset, on page 1 · Software and Hardware Support for Factory Reset, on page 3 · Prerequisites for Performing Factory Reset, on page 3 · Restrictions for Performing a Factory Reset, on page 4 · When to Perform Factory Reset, on page 4 · How to Perform a Factory Reset, on page 4 · What Happens after a Factory Reset, on page 5

Feature Information for Factory Reset

Table 1: Feature Information for Factory Reset

Lebitso la Sebopeho

Litokollo

Option to retain RUM reports, SLR, Cisco IOS XE Bengaluru 17.5.1 and HSEC key using the factory-reset keep-licensing-infocommand

Sireletseha Factory Reset

Cisco IOS XE Bengaluru 17.6.1

Feature Information This feature was introduced.
Added the factory-reset all secure command.

Tlhahisoleseding ka Femethari Reset
Factory Reset is a process of clearing the current running and start-up configuration information on a device, and resetting the device to an earlier, fully-functional state.
The factory reset process uses the factory-reset all command to take backup of existing configuration, and then reset the router to an earlier, fully functional state. The duration of the factory reset process is dependent on the storage size of the router. It can vary between 30 minutes on a C8500 consolidated platform, and up to 3 hours on a high availability setup.

Seta fektheri 1

Tlhahisoleseding ka Femethari Reset

Hlahisa Fektheri bocha

From Cisco IOS XE Bengaluru 17.6 release and later, you can use the factory-reset all secure command to reset the router and securely clear the files stored in the bootflash memory.
Table 2: Data Erased or Retained during Factory Reset

Command Name factory-reset all secure

Lintlha li hlakotsoe

Lintlha li bolokiloe

Non-volatile random-access memory (NVRAM) data

Data from remote field-replaceable units (FRUs).

OBFL (Onboard Failure Logging) Value of configuration register

likota

Bohlokoa

From Cisco IOS XE 17.14.1a, the

value of the configuration register

can be erased using the

factory-reset all secure command

on C8500L-8S4X, C8475-G2 and

C8455-G2.

Lilaesense

Litaba tsa USB

User data, startup, and running configuration

Credentials (Secure Unique Device Identifier [SUDI] certificates, public key infrastructure (PKI) keys, and FIPS-related keys)

ROMMON mefuta e fapaneng

All writeable file systems and personal data.
Note If the current boot image is a remote image or stored on a USB, NIM-SSD, or such, ensure that you take a backup of the image before performing factory reset.

Seta fektheri 2

Hlahisa Fektheri bocha

Software and Hardware Support for Factory Reset

Lebitso la Taelo

Lintlha li hlakotsoe

Lintlha li bolokiloe

factory-reset keep-licensing-info

· License Boot level configuration
· Throughput level configuration
· Smart license transport type
· Smart license URL data

· Real User Monitoring (RUM) Reports (open/unacknowledged license usage report)
· Usage reporting details (last ACK received, next ACK scheduled, last/next report push)
· Unique Device Identification (UDI) trust codes
· Customer policy received from CSSM
· SLAC, SLR authorization codes return codes
· Factory installed purchase information

After the factory reset process is complete, the router reboots to ROMMON mode. If you have the zero-touch provisioning (ZTP) capability setup, after the router completes the factory reset procedure, the router reboots with ZTP configuration.

Software and Hardware Support for Factory Reset
· This feature is supported on all Cisco Catalyst 8500 and 8500L Series Edge Platforms.
· Factory Reset process is supported on standalone routers as well as on routers configured for high availability.

Litlhoko tse hlokahalang bakeng sa ho etsa Factory Reset
· Ensure that all the software images, configurations and personal data is backed up before performing factory reset.
· Ensure that there is uninterrupted power supply when factory reset is in progress.
· The factory reset process takes a backup of the boot image if the system is booted from an image stored locally (bootflash or hard disk). If the current boot image is a remote image or stored on an USB, NIM-SSD or such, ensure that you take a backup of the image before performing factory reset.
· The factory-reset all secure command erases all files, including the boot image, even if the image is stored locally. If the current boot image is a remote image or stored on a USB, NIM-SSD, or such, ensure that you take a backup of the image before performing secure factory reset.

Seta fektheri 3

Restrictions for Performing a Factory Reset

Hlahisa Fektheri bocha

· Ensure that ISSU/ISSD (In- Service Software Upgrade or Downgrade) is not in progress before performing factory reset.

Restrictions for Performing a Factory Reset
· Any software patches that are installed on the router are not restored after the factory reset operation.
· If the factory reset command is issued through a Virtual Teletype (VTY) session, the session is not restored after the completion of the factory reset process.

When to Perform Factory Reset
· Return Material Authorization (RMA): If a router is returned back to Cisco for RMA, it is important that all sensitive information is removed.
· Router is compromised: If the router data is compromised due to a malicious attack, the router must be reset to factory configuration and then reconfigured once again for further use.
· Repurposing: The router needs to be moved to a new topology or market from the existing site to a different site.

Mokhoa oa ho etsa Reset ea Fektheri
Before you begin Refer Table 2 to determine which information is going to be deleted and retained. Based on the information you require, execute the appropriate command mentioned below.

Tsamaiso

Mohato oa 1 Mohato oa 2

Log in to a Cisco Catalyst 8500 or 8500L device.
Important If the current boot image is a remote image or is stored in a USB or a NIM-SSD, ensure that you take a backup of the image before starting the factory reset process.
This step is divided into two parts (a and b). If you need to retain the licensing information while performing the factory-reset command, follow step 2. a. If you do not need to retain the licensing information and want all the data to be erased, perform step 2. b. a) Execute factory-reset keep-licensing-info command to retain the licensing data.
The system displays the following message when you use the factory-reset keep-licensing-info command:
Router# factory-reset keep-licensing-info
The factory reset operation is irreversible for Keeping license usage. Are you sure? [confirm]

Seta fektheri 4

Hlahisa Fektheri bocha

What Happens after a Factory Reset

Mohato oa 3

This operation may take 20 minutes or more. Please do not power cycle.
Dec 1 20:58:38.205: %PMAN-5-EXITACTION: R0/0: pvp: Process manager is exiting: process exit with reload chassis code /bootflash failed to mount Dec 01 20:59:44.264: Factory reset operation completed. Initializing Hardware …
Current image running: Boot ROM1
Last reset cause: LocalSoft
ISR4331/K9 platform with 4194304 Kbytes of main memory rommon 1
b) Execute the factory-reset all secure 3-pass command to securely erase all data.
The system displays the following message when you use the factory-reset all secure 3-pass command:
Router# factory-reset all secure 3-pass
The factory reset operation is irreversible for securely reset all. Are you sure? [confirm] This operation may take hours. Please do not power cycle.
*Jun 19 00:53:33.385: %SYS-5-RELOAD: Reload requested by Exec. Reload Reason: Factory Reset.Jun 19 00:53:42.856: %PMAN-5-EXITACTION:
Enabling factory reset for this reload cycle Jun 19 00:54:06.914: Factory reset secure operation. Write 0s. Please do not power cycle. Jun 19 01:18:36.040: Factory reset secure operation. Write 1s. Please do not power cycle. Jun 19 01:43:49.263: Factory reset secure operation. Write random. Please do not power cycle. Jun 19 02:40:29.770: Factory reset secure operation completed.
Initializing Hardware ….
Enter confirm to proceed with the factory reset.
Note The duration of the factory reset process depends on the storage size of the router. It can extend between 30 minutes and up to 3 hours on a high availability setup. If you want to quit the factory reset process, press the Escape key.

What Happens after a Factory Reset
After the factory reset is successfully completed, the router boots up. However, before the factory reset process started, if the configuration register was set to manually boot from ROMMON, the router stops at ROMMON. After you configure Smart Licensing, execute the #show license status command, to check whether Smart Licensing is enabled for your instance.
Note If you had Specific License Reservation enabled before you performed the factory reset, use the same license and enter the same license key that you received from the smart agent.

Seta fektheri 5

What Happens after a Factory Reset

Hlahisa Fektheri bocha

Seta fektheri 6

Litokomane / Lisebelisoa

CISCO C8500 Edge Platforms Data Router [pdf] Bukana ea Mosebelisi
C8500, C8500L-8S4X, C8475-G2, C8455-G2, C8500 Edge Platforms Data Router, C8500, Edge Platforms Data Router, Data Router, Router

Litšupiso

Tlohela maikutlo

Aterese ea hau ea lengolo-tsoibila e ke ke ea phatlalatsoa. Libaka tse hlokahalang li tšoailoe *