1. Selelekela
This manual provides essential instructions for the safe and effective operation, maintenance, and troubleshooting of your Fluke 362 200A AC/DC Clamp Meter. Please read this manual thoroughly before using the device to ensure proper functionality and safety.
The Fluke 362 is a compact and versatile clamp meter designed for measuring AC and DC current up to 200A, AC and DC voltage up to 600V, resistance up to 3000 Ω, and continuity. Its ergonomic design and robust construction make it suitable for various electrical measurement tasks.
2. Boitsebiso ba Tšireletseho
WARNING: To prevent possible electrical shock, fire, or personal injury, read all safety information before you use the product.
- Kamehla khomarela mekhoa ea tšireletso ea lehae le ea naha.
- Do not use the meter if it is damaged or operating abnormally.
- Ensure the function switch is in the correct position for the measurement being performed.
- Se ke oa etsa kopo ho feta bophahamo bo lekantsoengtage, joalo ka ha ho tšoailoe methareng, lipakeng tsa liteishene kapa lipakeng tsa boemelo le sebaka sa lefatše.
- The Fluke 362 is rated for CAT III 600 V. This rating indicates suitability for measurements in distribution boards, circuit breakers, wiring, including cables, bus-bars, junction boxes, switches, and socket outlets in the fixed installation, and industrial use equipment.
- E-ba hlokolosi ha u sebetsa le voltages above 30 V AC RMS, 42 V peak, or 60 V DC. These voltage baka kotsi e tshosang.
- Remove test leads from the circuit before opening the battery cover.
- Kenya libeteri sebakeng sa tsona ha sesupo sa betri e tlase se hlaha ho netefatsa lipalo tse nepahetseng.
3. Sehlahisoa Overview
The Fluke 362 clamp meter features a robust design for reliable performance in various environments. Familiarize yourself with its components:

Setšoantšo sa 1: Pele view of the Fluke 362 Clamp Meter, showing the display, function dial, jaw, and buttons.

Figure 2: The Fluke 362 Clamp Meter held in a gloved hand, illustrating its compact size and ergonomic design for single-hand operation.
Likarolo tsa Bohlokoa:
- Hona joale Clamp Mohlahare: For non-contact AC/DC current measurements. Features an 18 mm triangular jaw for access in tight spaces.
- Mosebetsi oa ho Daela: Rotary switch to select measurement functions (AC/DC current, AC/DC voltage, khanyetso, tsoelopele).
- Pontšo ea LCD: Large, easy-to-read digital display for measurement results.
- TSHWARA Konope: E emisa 'malo oa hajoale skrineng.
- Konopo ea ZERO: Used to clear the display for DC current measurements, compensating for any offset.
- Lits'ebetso tsa ho kenya: Bakeng sa ho hokahanya liteishene tsa liteko bakeng sa voltage, khanyetso, le litekanyo tsa ho tsoela pele.
Likarolo tsa Bohlokoa:
- 200 A AC/DC current measurement capability.
- 600 V AC/DC voltage measurement capability.
- 3000 Ω resistance range.
- Continuity detection with audible indicator.
- Zero function for accurate DC measurements.
- Data hold function to capture readings.
- Large, clear display for easy viewng.
- Compact and lightweight design for one-hand operation.
- CAT III 600 V safety rating.
4. Seta
4.1 Ho kenya Betri
The Fluke 362 is battery-powered. Although batteries are not included with all packages, they are required for operation. To install or replace batteries:
- Ensure the meter is turned OFF and no test leads are connected.
- Beha sekoaelo sa kamore ea betri ka morao ho mithara.
- Use a screwdriver to loosen the screw(s) securing the cover.
- Remove the cover and insert the required batteries, observing correct polarity (+/-).
- Tlosa sekoaelo sa betri ebe u tiisa sekoahelo.
4.2 Khokahano ea Moetapele oa Teko
Bakeng sa voltage, resistance, and continuity measurements, connect the test leads to the input terminals:
- Insert the black test lead into the “COM” (common) terminal.
- Insert the red test lead into the “VΩ” (voltage/resistance) terminal.
5. Litaelo tsa Ts'ebetso
5.1 Ho Matlafatsa/Ho tima
Rotate the function dial from the “OFF” position to any desired measurement function to power on the meter. To power off, rotate the dial back to the “OFF” position.
5.2 Khetho ea Mosebetsi
Use the rotary function dial to select the desired measurement mode (e.g., A∼ for AC current, A— for DC current, V∼ for AC voltage, V— for DC voltage, Ω for resistance, or continuity).
5.3 Tekanyo ea Hona Joale ea AC/DC (Clamp)
To measure current using the clamp mohlahare:
- Rotate the function dial to A∼ (AC current) or A— (DC current).
- For DC current measurements, press the “ZERO” button to clear any offset before clampng.
- Bula clamp mohlahare ka ho toboketsa setlokotsebe.
- Enclose only one conductor within the jaw. Ensure the jaw is fully closed.
- Bala boleng ba hajoale ponts'o.
5.4 AC/DC Moqtage Tekanyo
Ho lekanya voltage:
- Hokela lintlha tsa tlhahlobo joalo ka ha ho hlalositsoe Karolong ea 4.2.
- Rotate the function dial to V∼ (AC voltage) or V— (DC voltagle).
- Hokela di-probe tsa teko ka ho bapa le potoloho kapa karolo eo o batlang ho e lekanya.
- Bala voltagboleng ho pontšo.
5.5 Tekanyo ea Khanyetso
Ho lekanya khanyetso:
- Ensure the circuit or component is de-energized before measuring resistance.
- Hokela lintlha tsa tlhahlobo joalo ka ha ho hlalositsoe Karolong ea 4.2.
- Rotate the function dial to Ω (resistance).
- Connect the test probes across the component.
- Bala boleng ba ho hanyetsa ponts'ong.
5.6 Tsoelopele Test
Ho etsa tlhahlobo ea ho tsoelapele:
- Ensure the circuit or component is de-energized.
- Hokela lintlha tsa tlhahlobo joalo ka ha ho hlalositsoe Karolong ea 4.2.
- Rotate the function dial to the continuity position (often shared with resistance, indicated by a speaker icon).
- Connect the test probes across the component or wire.
- The meter will emit an audible tone if continuity is detected (resistance below a certain threshold).
5.7 Zero Function (DC Measurements)
The “ZERO” button is primarily used for DC current measurements. Before taking a DC current reading, with the clamp jaw open and no conductor inside, press the “ZERO” button to eliminate any residual offset and ensure accurate readings.
5.8 Ts'ebetso ea Ts'ebetso ea Boitsebiso
Press the “HOLD” button to freeze the current reading on the display. This is useful for taking readings in hard-to-see locations. Press “HOLD” again to release the reading and return to live measurement.
6. Tlhokomelo
6.1 Ho hloekisa
To clean the meter, wipe it with a damp lesela le sesepa se bonolo. U se ke ua sebelisa li-abrasives kapa solvents. Netefatsa hore mitha e omme ka botlalo pele o sebelisoa.
6.2 Phetoho ea Betri
When the low battery indicator appears on the display, replace the batteries promptly to maintain measurement accuracy. Refer to Section 4.1 for battery installation instructions.
6.3 Polokelo
If the meter is not used for an extended period, remove the batteries to prevent leakage and damage. Store the meter in a dry, cool environment, away from direct sunlight and extreme temperatures.
7. Ho rarolla mathata
If you encounter issues with your Fluke 362, refer to the table below for common problems and solutions:
| Bothata | Lebaka le ka khonehang | Tharollo |
|---|---|---|
| Meter does not power on or display is blank. | Libetri tse shoeleng kapa tse kentsoeng ka phoso. | Sheba polarity ea betri kapa u fetole libeteri. |
| Litemana tse sa nepahalang. | Low battery, incorrect function selected, external interference, or un-zeroed DC current. | Replace batteries, select correct function, move away from strong electromagnetic fields, or use the ZERO function for DC current. |
| Continuity tone is too low or inaudible. | Noisy work environment. | Relocate to a quieter area or rely on the visual display for continuity indication. |
| “OL” (Overload) displayed. | Measurement exceeds the meter’s range. | Ensure the measurement is within the specified range for the selected function. |
If the problem persists after attempting these solutions, contact Fluke customer support.
8. Litlhaloso
| Paramethara | Tlhaloso |
|---|---|
| Brand | Fluke |
| Mohlala | 362 |
| Sebaka sa Hona joale sa AC | 200 A |
| DC Palo ea Hajoale | 200 A |
| Mofuta oa AC Voltage Range | 600 V |
| DC Moqtage Range | 600 V |
| Resistance Range | 3000 Ω |
| Lintlha tsa polokeho | CAT III 600 V |
| Ho Bula Mohlahare | 18 limilimithara |
| Mohloli oa Matla | Matla a Battery |
| Litekanyo (L x W x H) | 7.87 x 1.57 x 3.94 lisenthimithara |
| Boima ba Ntho | 14.1 ounces (400 Grams) |
| UPC | 095969672191 |
| Nomoro ea Mohlala | 4345498 |
9. Tiisetso le Tšehetso
Fluke products are designed for reliability and performance. For specific warranty details, please refer to the warranty card included with your product or visit the official Fluke websebaka. Boloka rasiti ea hau ea theko e le bopaki ba hore u rekile.
For technical support, service, or calibration, please contact Fluke customer service through their official website or the contact information provided in your product packaging. When contacting support, please have your model number (Fluke 362) and serial number (if applicable) ready.