1. Увод
This manual provides essential information for the safe and correct installation, operation, and maintenance of the Truma Ignition Safety Valve Set, designed for use with Truma S 3002 and S 5002 heaters. Please read these instructions thoroughly before installation and use to ensure proper function and safety.
2. Безбедносне информације
УПОЗОРЕЊЕ: Неправилна инсталација, подешавање, преинака, сервис или одржавање могу узроковати оштећење имовине, повреде или смрт. Пажљиво прочитајте упутства за инсталацију, рад и одржавање пре инсталирања или сервисирања ове опреме.
- Инсталацију и сервис мора обавити квалификовани инсталатер, сервисна агенција или добављач гаса.
- Always shut off the gas supply before performing any maintenance or service.
- Ensure adequate ventilation when operating gas appliances.
- Check for gas leaks after installation or service using an approved leak detection solution.
- Do not use open flames to check for gas leaks.
3. Садржај пакета
Пре него што наставите са инсталацијом, проверите да ли су све компоненте присутне и неоштећене.
- Ignition protection valve
- О-прстен
- Нут
- Прстен за сечење
- Associated wiring and mounting brackets (as pictured)

Слика 1: Components of the Truma Ignition Safety Valve Set. This image displays the main valve assembly with attached wiring, a flexible hose, an O-ring, a nut, a cutting ring, and two metal mounting brackets.
4. Подешавање и инсталација
This ignition safety valve set is designed for specific Truma S 3002 and S 5002 heaters. Refer to your heater's primary manual for detailed instructions on accessing the valve area.
- Припрема: Ensure the gas supply to the heater is completely shut off and the system has cooled down. Disconnect any electrical power to the heater.
- Уклоните стари вентил (ако је применљиво): Carefully disconnect the gas lines and electrical connections from the existing safety valve. Note the orientation and connections for proper reassembly.
- Инсталирајте нови вентил:
- Attach the new ignition safety valve to the heater using the provided mounting brackets. Ensure it is securely fastened.
- Connect the gas inlet and outlet lines. Use the new O-ring, nut, and cutting ring for a secure, leak-free connection. Tighten connections to manufacturer specifications, but do not overtighten.
- Connect the electrical wiring from the valve to the heater's control system. Ensure correct polarity and secure connections.
- Тест цурења: After installation, slowly turn on the gas supply. Apply an approved gas leak detection solution to all gas connections. Bubbles indicate a leak. If a leak is detected, immediately shut off the gas supply and re-tighten the connection. Repeat the leak test until no bubbles appear.
- Electrical Test: Restore electrical power to the heater and perform a functional test according to the heater's operating instructions.
Напомена: If you are unsure about any step of the installation process, consult a qualified gas appliance technician.
5. Операција
The Truma Ignition Safety Valve is an integral component of your Truma S 3002/5002 heater's safety system. It operates automatically to ensure safe gas flow.
- When the heater is switched on and an ignition signal is present, the safety valve opens to allow gas to flow to the burner.
- If the flame extinguishes unexpectedly (e.g., due to wind or gas supply interruption), the safety valve will automatically close the gas supply within a specified timeframe, preventing unburnt gas from accumulating.
- This valve does not require manual operation during normal use. Its function is entirely automatic and safety-critical.
6. Одржавање
Regular maintenance of your Truma heater system, including the ignition safety valve, is crucial for safe and efficient operation. While the safety valve itself requires minimal direct user maintenance, periodic checks are recommended.
- Годишња инспекција: It is recommended to have your entire Truma heating system, including the gas lines and safety valve, inspected annually by a qualified technician.
- Визуелна провера: Periodically inspect the valve and its connections for any signs of corrosion, damage, or loose fittings.
- Чишћење: Keep the area around the valve clean and free from dust or debris. Do not use harsh chemicals or abrasive cleaners.
- Замена компоненти: If any part of the safety valve set appears damaged or worn, it must be replaced with genuine Truma spare parts by a qualified technician.
КСНУМКС. Решавање проблема
If your Truma heater is not functioning correctly, and you suspect an issue with the ignition safety valve, consider the following:
| Проблем | Могући узрок | Решење |
|---|---|---|
| Heater does not ignite or repeatedly fails to ignite. | No gas supply, faulty ignition, or safety valve not opening. |
|
| Heater ignites but flame extinguishes quickly. | Insufficient gas pressure, faulty thermocouple/flame sensor, or safety valve closing prematurely. |
|
| Мирис гаса. | Цурење гаса. |
|
Важно: Do not attempt repairs on gas components unless you are a qualified and certified technician. Always prioritize safety.
8. Спецификације
- Тип производа: Ignition Safety Valve Set
- Бренд: Трума
- Компатибилност модела: Truma S 3002, Truma S 5002 heaters
- Број дела: ФРА309492
- Материјал: Plastic (valve body may contain metal components)
- Димензије (Д к Ш к В): Приближно 2.76 к 6.3 к 2.76 инча (7 к 16 к 7 цм)
- Тежина артикла: Приближно 14.8 унце (420 г)
- Спољна завршна обрада: Паинтед
- Величина улазног прикључка: 1.6E+2 Millimeters (160mm)
- Тип улазног прикључка: Cutting Ring
- Величина прикључка за утичницу: 16 милиметара
- Тип прикључка на утичницу: Cutting Ring
- Број портова: 2
- Спецификација испуњена: CE
9. Информације о гаранцији
Specific warranty terms for the Truma Ignition Safety Valve Set are provided by the manufacturer, Truma. Please refer to the warranty documentation included with your original purchase or visit the official Truma webсајт за детаљне информације о гаранцији, трајању и поступцима за рекламације.
Сачувајте доказ о куповини ради гаранције.
10. Корисничка подршка
For technical assistance, spare parts, or service inquiries, please contact Truma customer support or an authorized Truma service center.
You can find contact information and a list of authorized service partners on the official Truma webсајт: ввв.трума.цом
When contacting support, please have your product model number (FRA309492) and purchase details ready.