1. Увод
The GIMA OXY 6 Finger Pulse Oximeter is a portable device designed for non-invasive spot-checking of arterial oxygen saturation (SpO2) and pulse rate. It is suitable for use in medical and hospital environments, as well as for personal use under medical guidance. This manual provides essential information for the safe and effective operation of the device.
2. Безбедносне информације
Please read all safety warnings and precautions before using the device. Failure to do so may result in inaccurate readings or device malfunction.
- This device is intended for spot-checking and not for continuous monitoring.
- Немојте користити оксиметар у МРИ или ЦТ окружењу.
- Држите уређај даље од воде и влаге.
- Consult a medical professional for interpretation of readings. This device is not a substitute for professional medical advice.
- Ensure the finger is clean and free of nail polish or artificial nails, as these can affect accuracy.
- Avoid excessive movement during measurement to ensure stable readings.
3. Производ је готовview
The GIMA OXY 6 features a high-resolution OLED color display showing SpO2, pulse rate, pulse bar graph, perfusion index (PI), and battery level. It is designed for ease of use with a compact form factor.

Слика 1: Фронт view of the GIMA OXY 6 Pulse Oximeter, displaying SpO2 and pulse rate values on its screen.
3.1. Садржај пакета

Слика 2: The package includes the GIMA OXY 6 Pulse Oximeter, a plastic case, AAA batteries, and a lanyard.
- GIMA OXY 6 Pulse Oximeter
- 2 к ААА батерије
- Пластична торбица за ношење
- Ланиард
- Упутство за употребу

Слика 3: The GIMA OXY 6 Pulse Oximeter attached to a lanyard, demonstrating its portability and ease of carrying.
4. Подешавање
4.1. Инсталација батерије
- Отворите поклопац одељка за батерију који се налази на задњој страни уређаја.
- Insert two AAA batteries according to the polarity indicators (+/-) inside the compartment.
- Добро затворите поклопац одељка за батерије.

Слика 4: Open battery compartment showing placement for two AAA batteries.
5. Упутство за употребу
5.1. Мерење
- Ensure the device has fresh batteries installed.
- Отворите цлamp оксиметра.
- Insert one finger (preferably the index, middle, or ring finger) into the rubber opening of the oximeter, ensuring the finger is fully inserted and resting on the sensor. The recommended finger thickness for this model is 1-22 mm.
- Отпустите цлamp. The device will automatically turn on and begin measurement.
- Keep your hand still during the measurement. Avoid bending your finger or making hand movements.
- Readings for SpO2, Pulse Rate, and Perfusion Index (PI) will appear on the display within a few seconds.

Слика 5: The GIMA OXY 6 Pulse Oximeter correctly placed on a finger for measurement.
5.2. Разумевање дисплеја
- СпО2: Peripheral Oxygen Saturation, displayed as a percentage.
- ПР: Pulse Rate, displayed in beats per minute (bpm).
- ПИ: Perfusion Index, a numerical value indicating the strength of the pulse signal at the sensor site.
- Pulse Bar Graph: Visual representation of pulse strength.
- Индикатор батерије: Приказује тренутни ниво батерије.
5.3. Automatic Power Off
The device will automatically power off after approximately 8 seconds of inactivity or when the finger is removed.
5.4. Лов Волtagе Аларм
Када је батерија волtage is low, a low voltage alarm will be indicated on the display. Replace the batteries promptly to ensure accurate operation.
5.5. Гласовни водич
The GIMA OXY 6 features an 8-language voice guide (English, French, Italian, Spanish, Greek, Portuguese, Arabic) for enhanced usability. Refer to the full manual for specific instructions on activating and changing voice guide settings.
6. Одржавање
6.1. Чишћење
- Clean the surface of the oximeter with a soft cloth dampened with medical alcohol (70% ethanol or isopropanol).
- Do not immerse the device in water or any cleaning solution.
- Ensure the device is completely dry before reuse.
6.2. Замена батерије
Замените батерије када је слаба запреминаtage indicator appears. Always use two new AAA alkaline batteries. Dispose of used batteries according to local regulations.
6.3. Складиштење
Store the oximeter in its plastic carrying case in a cool, dry place, away from direct sunlight and extreme temperatures. Remove batteries if the device will not be used for an extended period.
КСНУМКС. Решавање проблема
| Проблем | Могући узрок | Решење |
|---|---|---|
| Нема приказа након укључивања | Батерије су истрошене или неправилно постављене. | Replace batteries or re-install them correctly, observing polarity. |
| Нетачна очитавања | Finger not properly inserted; excessive movement; nail polish; cold finger. | Re-insert finger correctly; remain still; remove nail polish; warm the finger. |
| "Finger Out" or similar error message | Finger not detected or improperly placed. | Ensure finger is fully inserted and resting on the sensor. |
| Уређај се неочекивано искључује | Low battery; automatic power-off due to inactivity. | Replace batteries; ensure finger is inserted for measurement. |
8. Спецификације
| Број модела | 34285 (OXY 6) |
| Дисплаи Типе | OLED Color Display |
| Меасуремент Параметерс | SpO2, Pulse Rate, Perfusion Index (PI) |
| SpO2 Measurement Range | (Typical range, refer to device for exact range) |
| Опсег мерења пулса | (Typical range, refer to device for exact range) |
| Прецизност | High precision and repeatability with noise suppression |
| Захтеви за напајање | 2 x AAA алкалне батерије од 1.5 V |
| Трајање батерије | Approximately 3 hours of continuous operation with full batteries |
| Димензије (Д к Ш к В) | 16 к 5.5 к 10 цм |
| Тежина | 200 грама (укључујући батерије) |
| Finger Thickness Range | 1-22 мм |
| Гласовни водич | 8 languages (GB, FR, IT, ES, GR, PT, Arabic) |
9. Гаранција и подршка
Information regarding specific warranty terms and customer support for the GIMA OXY 6 Pulse Oximeter is not provided in this document. Please refer to the product packaging or contact GIMA customer service for details.