IOMOD User’s Guide
IOMOD
IOMOD is an external device that connects to the DVR or NVR via RS-485 to extend the number of alarm inputs up to 16.
HW Connection
- Connect the RS-485 terminal of IOMOD and DVR/NVR.
- Connect the DC 12V Adapter supplied with the IOMOD.
SW Setting
Go to Setup → Device → Controller & PTZ and activate ‘Alarm Box’ ON.
[Note]
If the alarm box is turned “on”, the sensor input of the DVR/NVR itself does not work.
When the Alarm Box is turned “on”, the Keyboard Controller can not be used.
Specifications
Items | Specifications |
Model | IOMOD |
Alarm Inputs | 16 (Terminal Blocks) |
Interface with DVR/NVR | RS-485 (Terminal Block) |
Front LEDs | Power (RED) |
Alarm (Yellow) | |
RS485 (Green) | |
Power | DC 12V 3A Adaptor |
Dimension (W x H x D) | 6.7″ x 1.0″ x 1.9″ (170mm x 25mm x 48mm) |
DWG
• 516-933-4900
• dwgdistribution.com
Documents / Resources
![]() |
speco technologies IOMOD External Alarm Box Module [pdf] User Guide IOMOD External Alarm Box Module, IOMOD, External Alarm Box Module, Alarm Box Module, Box Module |