Spa Electrics AGRX R2 Multi Plus RGB LED Colour Retro

Specifications

  • Model: AGRX R2
  • Compatible with various pool light models: Astral Calidoray,
  • Astral FLX, Aquaquip Evo-FG, Aqua De Light/Autumn Solar, Lumascape
  • PAL, EvenGlow PAL 2000, Spa Electrics EMF/EMC, Spa Electrics EMV, Waterco Slim 90
  • Installation Types: Concrete/Fiberglass, Vinyl

Read This First

This booklet contains important information about the correct installation and handling of the AGRX Series lights. Please read this booklet carefully before commencing installation to familiarize yourself with the included parts, accessories, and correct installation procedures.

Tools Required

  • Flat-blade screwdriver
  • Phillips Head (No 2) screwdriver
  • Cable stripper/Side Cutters
  • Pliers

Included Parts

  • R2 Adaptor Plate (P/N: SAMB 003)
  • AGRX Light
  • R2 Rim (P/N: AGRX 008R2)
  • EM Adaptor (P/N: SAMB 006)
  • PAL Adaptor (P/N: SAMB 009)

Transformer Verification

  1. Turn power off to existing 12V transformer.
  2. Check transformer for poor condition.

Light Removal

  1. Remove existing light. Retain existing mounting screws.
  2. Disconnect existing light and discard old light housing.

Cable Preparation

  1. Strip power cable to specified length. Cut cable back until fresh copper appears if needed.
  2. Start assembly of connector plug by feeding the connector collar and gland nut onto the cable.
  3. Choose the appropriate gland that fits snugly on the existing power cable.

“`

This booklet contains important information about the correct installation and handling of the AGRX Series lights. Please read this booklet carefully before commencing installation to familiarise yourself with the included parts, accessories and correct installation procedures.

BEFORE YOU START
· If required, ensure that the transformer is installed by a suitable qualified persons (e.g., registered pool builder and/or qualified electrician), in accordance with AS/NZS 3000:2018 standards.
· For safe and proper installation, ensure that only those parts supplied with the system are used.
· Check that there is enough cable behind the existing light to allow for servicing above water, preferably at ground-level pool-side.


· Ensure the pool light end of cable is circular and free of damage or imperfections i.e., cuts, cracks or deformation. If possible, trim back until fresh end of cable is available.
· Confirm existing transformer is a iron core type, 12V AC ONLY and in good working order (If in doubt contact Spa Electrics).

CLEANING
· Only use warm water and a soft brush or cloth to clean AGRX Series. DO NOT use detergents or spirits as this can damage the light and void your warranty.
USE
· Operating the light for at least 15 minutes every week is advised (all year round)
· AGRX Series lights are suited for both domestic and commercial installations.
3

WARNING
· The AGRX Series light must only be powered by a 12V AC iron core type transformer.
· DO NOT use electronic or switch-mode transformers with AGRX Series lights. These transformers will damage the light and void your product warranty.
· Pool chemicals & pH levels: Due to the corrosive nature of unbalanced pool chemicals, Spa Electrics strongly recommends that your pool water is balanced prior to installing your pool lights or any plastic or stainless-steel components and tested weekly to maintain these levels. pH level should be maintained between 7.2 ­ 7.6 at all times to ensure the longevity of these components.


– Failure to do so can result in chemical damage to the light housing and pool fittings, including stainless steel components
– Please note: Lights or components found to have excessive chemical damage will not be covered under our manufacturer’s warranty policy
· This light contains no user-serviceable parts; opening the light will void the product warranty.

TOOLS REQUIRED
Flat-blade screw driver Phillips Head (No 2) screw-driver

Cable stripper/Side Cutters Pliers

IMPORTANT NOTES
The use of power tools (such as 240V and cordless drills) during installation is not recommended as these devices can cause faults and damage to light components.
If you are unsure, please contact Spa Electrics

4

INCLUDED PARTS
MODEL: AGRX R2

R2 ADAPTOR PLATE (P/N: SAMB 003)

AGRX LIGHT

R2 RIM (P/N: AGRX 008R2)

EM ADAPTOR (P/N: SAMB 006)

PAL ADAPTOR (P/N: SAMB 009)

ADAPTOR TOOL (P/N: VIVO 045 )

ADAPTOR THREAD (P/N: VIVO 041)

LANOLIN

1 X WARRANTY CARD

PLUG ASSEMBLY (P/N: AGRX 003)

2 X LUMASCAPE SCREWS

Connector Collar

Gland

Glands X 3

Connector Strain Relief Screw Terminal

Nut

Sizes Provided

Barrel

Clip

End with filling

(Optional) screws attached

5

TRANSFORMER VERIFICATION
1 TURN POWER OFF
TURN POWER
OFF
TO EXISTING 12V TRANSFORMER
2 CHECK TRANSFORMER
EXISTING TRANSFORMER MUST BE: · 12V AC ONLY · MIN 15 WATT (PER LIGHT) · IN GOOD WORKING ORDER
EXISTING TRANSFORMER MUST NOT BE: · DC OR LED DRIVER · ELECTRONIC OR SWITCH MODE · WEATHER DAMAGED OR IN
OTHERWISE POOR CONDITION
6

LIGHT REMOVAL

1 REMOVE EXISTING LIGHT

IMPORTANT
RETAIN EXISTING MOUNTING SCREWS. SEE PAGE 12

REMOVE EXISING LIGHT FROM NICHE

2 DISCONNECT EXISTING LIGHT

DISCARD OLD LIGHT HOUSING
7

CABLE PREPARATION

1 CABLE PREPARATION
STRIP POWER CABLE TO SPECIFIED LENGTH

NOTE
IF CABLE LENGTH ALLOWS, CUT CABLE BACK UNTIL FRESH COPPER APPEARS

24mm (15/16″)

 

2 START ASSEMBLY OF CONNECTOR PLUG

FEED THE CONNECTOR COLLAR AND GLAND NUT ONTO THE CABLE, AS SHOWN
8

GLAND NUT

CONNECTOR COLLAR

3 CHOOSE THE APPROPRIATE GLAND

SELECT A CABLE GLAND FROM THE THREE SUPPLIED THAT SNUGLY FITS THE EXISTING POWER CABLE

GLANDS X 3 SIZES PROVIDED

SMALL GLAND YELLOW

MEDIUM GLAND RED

LARGE GLAND BLUE

IMPORTANT
IF GLAND IS EXCESSIVELY TIGHT OR BULDGING WHEN FITTED, REPLACE WITH LARGER GLAND SIZE
4 CONTINUE ASSEMBLY OF CONNECTOR PLUG

FEED THE CONNECTOR BARREL ONTO THE CABLE

CONNECTOR BARREL

9

5 CHECK SCREWS ON SCREW TERMINAL END

CHECK IF SCREWS ARE PRESENT IN THE TOP OF THE SCREW TERMINAL END

WITH SCREWS

WITHOUT SCREWS

USE A MANUAL PHILLIPS HEAD SCREWDRIVER TO ENSURE THAT THE 2 SCREWS INDICATED ARE FULLY SEATED. PROCEED TO STEP 6.

CHECK THERE ARE NO HOLES IN THE INDICATED LOCATIONS.
PROCEED TO STEP 6.

10

6 CHECK SCREWS ON SCREW TERMINAL END

STRAIN RELIEF CLIP
(OPTIONAL)
OPTION 1: WHEN USING THE LARGE CABLE GLAND, THE STRAIN RELIEF CLIP IS NOT REQUIRED. FOLLOW STEP 7A (IGNORE STEP 7B).
OPTION 2: THE STRAIN RELIEF CLIP MUST BE USED WHEN THE SMALL OR MEDIUM CABLE GLAND IS USED. FOLLOW STEP 7B (IGNORE STEP 7A).

STRAIN RELIEF CLIP REQUIRED

SMALL GLAND

MEDIUM GLAND

LARGE GLAND

7A CONNECT THE SCREW TERMINAL END

SCREW TERMINAL END
1: FEED THE TWO STRIPPED CABLE ENDS THROUGH THE TWO HOLES IN THE BACK OF THE SCREW TERMINAL END
1

19mm 7mm

2: USE A FLAT BLADE SCREWDRIVER TO

2

TIGHTEN THE FASTENERS ON EITHER SIDE OF THE SCREW TERMINAL

11

7B CONNECT THE SCREW TERMINAL END

SCREW TERMINAL
END

STRAIN RELIEF CLIP

1: ATTACH THE STRAIN RELIEF CLIP TO THE SCREW TERMINAL END

1

2: FEED THE TWO STRIPPED CABLE ENDS THROUGH THE TWO HOLES IN THE BACK OF THE SCREW TERMINAL END
2

19mm

7mm

3: USE A FLAT BLADE SCREWDRIVER TO TIGHTEN THE FASTENERS ON EITHER SIDE OF THE SCREW TERMINAL

3

4: TWIST THE SCREW TERMINAL AND LOOP CABLE ENDS UNDER THE STRAIN RELIEF CLIP
4

12

9 START ASSEMBLY OF CONNECTOR PLUG
CAREFULLY THREAD CONNECTOR BARREL ONTO SCREW TERMINAL AND TIGHTEN FIRMLY BY HAND
LEAVE THESE PARTS DISASSEMBLED UNTIL AFTER ADDING LANOLIN
10 ADD LANOLIN
LANOLIN USE
GENTLY WARM LANOLIN BEFORE USE
FILL BACK OF CONNECTOR BARREL WITH LANOLIN UP TO THE INDICATED POINT
FILL TO HERE (ALLOWING ROOM FOR GLAND)
13

12 CONTINUE ASSEMBLY OF CONNECTOR PLUG
1: SEAT CABLE GLAND ALL THE WAY INTO CONNECTOR (DO A VISUAL CHECK TO MAKE SURE A SEAL BETWEEN GLAND AND CABLE) 2: CAREFULLY THREAD GLAND NUT ONTO CONNECTOR BARREL 3: TIGHTEN GLAND NUT FIRMLY BY HAND
1 2
3
14

13 CONTINUE ASSEMBLY OF CONNECTOR PLUG
1: SLIDE CONNECTOR COLLAR ALL THE WAY TO THE END READY FOR ATTACHMENT TO THE LIGHT ASSEMBLY
1
ASSEMBLED VIEW OF CONNECTOR PLUG
15

ADAPTOR PLATE INSTALLATION

LIGHT
ASTRAL CALIDORAY ASTRAL FLX
AQUAQUIP EVO-FG AQUA DE LIGHT/AUTUMN SOLAR
LUMASCAPE PAL EVENGLOW
PAL 2000 SPA ELECTRICS EMF/EMC
SPA ELECTRICS EMV WATERCO SLIM 90

INSTALLATION TYPE
CONCRETE/FIBREGLASS FIBREGLASS FIBREGLASS
CONCRETE/FIBREGLASS CONCRETE/FIBREGLASS
CONCRETE FIBREGLASS CONCRETE/FIBREGLASS CONCRETE/FIBREGLASS
VINYL FIBREGLASS

INSTALL TYPE (A) INSTALL TYPE (B) SCREW LOCATIONS ADAPTOR REQUIRED

PAL ADAPTOR

C-C-C

SLOTS (SEE PG 13)

*AGRX 002

B-B

A-A

PAL ADAPTOR

PAL ADAPTOR

EM ADAPTOR

*AGRX 002

PAL ADAPTOR

R2 ADAPTOR PLATE (P/N: SAMB 003)

EM ADAPTOR (P/N: SAMB 004)

PAL ADAPTOR (P/N: SAMB 009)

16

AGRX 002 ­ * SOLD SEPARATELY INSTRUCTIONS ON PAGE 17

ADAPTOR INSTALL – TYPE (A)

1 IDENTIFY SCREW POSITIONS
Aquaquip EVO FG Slot locations
SCREW LOCATION B SCREW LOCATION A SCREW LOCATION C

SCREW LOCATION C SCREW LOCATION B SCREW LOCATION A
SCREW LOCATION C

SLOTS AQUAQUIP EVO FG
2 ATTACH ADAPTOR PLATE
PLACE THE ADAPTOR PLATE OVER THE NICHE AND FASTEN USING EXISTING SCREWS

NOTE
FOR LUMASCAPE INSTALLATIONS, PLEASE USE SCREWS PROVIDED

CONTINUE TO PAGE 15 17

ADAPTOR INSTALL – TYPE (B)
1 ATTACH NICHE ADAPTOR
ATTACH THE REQUIRED ADAPTOR (SEE TABLE ON PG 12) TO THE EXISTING NICHE
EM ADAPTOR CLIP THE EM ADAPTOR ONTO THE EXISTING EM BAYONET
PAL ADAPTOR THREAD THE PAL ADAPTOR INTO THE EXISTING NICHE

2 ATTACH ADAPTOR PLATE
PLACE THE ADAPTOR PLATE OVER THE EXISTING NICHE AND INSTALL THE ADAPTOR THREAD

ADAPTOR TOOL USE TOOL TO TIGHTEN THREAD
ADAPTOR TOOL USE TOOL TO TIGHTEN THREAD

18 CONTINUE TO PAGE 15

3 CONNECT THE TERMINALS
ALIGN THE TERMINAL PINS ON PLUG AND BACK OF LIGHT ASSEMBLY AND FIRMLY CONNECT TOGETHER
IMPORTANT NOTES
· DO NOT ADD SEALANTS, GREASES OR ADHESIVES · ENSURE ALL SURFACES ARE CLEAN AND DRY · DO NOT ASSEMBLE UNDERWATER
4 FASTEN PLUG TO LIGHT
THREAD PLUG COLLAR ONTO AGRX LIGHT AND TIGHTEN FIRMYLY BY HAND
5 INSTALL LIGHT ONTO SMALL ADAPTOR PLATE
ALIGN THE ARROW ON THE LIGHT WITH THE LEFT ARROW (11 O’CLOCK POSITION) ON THE SMALL ADAPTOR PLATE
Arrow alignment showing unlocked
position

Align Arrows

Unlocked Position
19

5 STEP 5 CONTINUED…
TWIST LIGHT CLOCKWISE UNTIL TOP ARROWS ALIGN
Locked Position
6 CLIP ON RIM
ALIGN THE ARROW ON THE RIM WITH THE TOP ARROW (12 O’CLOCK POSITION) ON THE ADAPTOR PLATE PRESS THE RIM ONTO THE LIGHT BY HAND
Align Arrows
20 CONTINUE TO PAGE 19

AGRX 002 PLATE ASSEMBLY

R2 ADAPTOR PLATE (P/N: SAMB 003)

AGRX 002 Kit Includes 2x Set of O’Rings. (2x3mm & 2x1mm)

ADAPTOR TOOL (P/N: VIVO 045)

AGRX LIGHT

R2 RIM (P/N: AGRX 008R2)

STEP 1
PLACE THE SMALL O’RINGS OVER THE AGRX 002 FRICTION FIT ADAPTOR

STEP 2
SLIDE THE FRICTION FIT ADAPTOR THROUGH THE ADAPTOR PLATE, ALIGNING THE TABS ON THE AGRX 002 ADAPTOR WITH THE SLOTS ON THE ADAPTOR PLATE
NOTE
IF MORE ENGAGEMENT IS REQUIRED, INSTALL THE LARGER O’RINGS ONTO THE AGRX 002 ADAPTOR
21

STEP 3
USING THE ADAPTOR TOOL PUSH THE AGRX 002 ADAPTOR INTO THE EXISTING NICHE PIPE
22 CONTINUE TO INSTALLATION PROCESS FROM PAGE 14

POST INSTALLATION CHECK
1 TEST SYSTEM
TURN POWER
ON
TO LOW VOLTAGE TRANSFORMER
23

NOTE
PLEASE STORE THIS MANUAL IN A SAFE PLACE FOR FUTURE REFERENCE
© COPYRIGHT 2025 SPA ELECTRICS PTY. LTD. ALL RIGHT RESERVED 2025 06 19

Documents / Resources

Spa Electrics AGRX R2 Multi Plus RGB LED Colour Retro [pdf] User Manual
AGRX R2, AGRX 002, AGRX 008R2, AGRX R2 Multi Plus RGB LED Colour Retro, AGRX R2, Multi Plus RGB LED Colour Retro, RGB LED Colour Retro, Colour Retro

References

Leave a comment

Your email address will not be published. Required fields are marked *