  1. Installation:
    Follow these steps to install the EA-8 Controller:
    1. Identify all the components listed in the manual.
    2. Mount the power module and controller in the designated locations.
    3. Connect the RJ45 cable, terminal block, and wire harness as instructed.
    4. Secure all components using the provided screws and brackets.
  2. Powering On:
    To power on the controller:
    1. Ensure the input voltage is within the specified range.
    2. Connect the power source to the controller.
    3. Verify that all connections are secure before turning on the device.
  3. Configuration:
    To configure the EA-8 Controller:
    1. Refer to the instruction card for detailed setup instructions.
    2. Adjust settings as needed based on your requirements.
    3. Test the controller to ensure proper functionality.

FAQ:

  • Q: What should I do if the controller does not power on?
    A: Check the input voltage and connections to ensure everything is properly set up and connected.
  • Q: How can I reset the controller to factory settings?
    A: Refer to the instruction card for information on resetting the controller to factory defaults.

SAFETY WARNING

IMPORTANT NOTICE TO INSTALLER: 

  • Make sure to read and understand all instructions and warnings before proceeding with the installation of this product. Ensure the manual and all warning cards are delivered to the end user of this equipment.
  • HIGH-CURRENT interconnects must be properly terminated. Poor crimp quality can cause heat build-up and fire. Follow crimp connector manufacturer instructions.
  • DO NOT use the system to disconnect headlights, brake lights, or other safety equipment.
  • The unit may become hot to the touch during normal operation.
  • Failure to properly install connectors, fuses, or wiring may cause vehicle failure or fire.
  • Installation must only be performed by a trained technician. The installer must determine vehicle wiring configuration and proper integration of the system.
  • Use proper wire gauge. All power wires connecting to positive (+) or negative (-) battery terminal or local chassis ground (-) must be sized to supply at least 125% of max. Current and properly fused at the power source.
  • Install protective grommets when routing wire through a firewall or metal.

WARNING
DO NOT install this product or route its wires in the airbag deployment area. Doing so may cause damage to or reduce the effectiveness of the airbag, or create a projectile that could cause serious injury or death. To determine the air bag deployment area refer to the vehicle manufacturer’s manual.

NOTICE: 

  • Installers and users must comply with all applicable federal, state, and local laws regarding the use and installation of warning devices.
  • Improper use or installation may void warranty coverage.
  • To review our Limited Warranty Statement & Return Policy for this or any SoundOff Signal product, visit our website at https://soundoffsignal.com/warranty.
  • If you have questions regarding this product, contact Technical Services, Monday – Friday, 8 a.m. to 5 p.m. ET at 1.800.338.7337 (press #4).
  • Questions or comments that do not require immediate attention may be emailed to techgroup@soundoffsignal.com.

PACKAGE CONTENTS

CONTENTS
NO. COMPONENT QTY.
1 POWER MODULE 1
2 CONTROLLER 1
3 RJ45 CABLE (4M) 1
4 TERMINAL BLOCK 1
5 SELF-DRILLING SCREW (#8×1″) 4
6 6-PIN WIRE HARNESS 1
7 ADJUSTABLE SCREW MOUNT BRACKET 1
8 SELF-DRILLING SCREW (4X15MM) 2
9 DECALS 1
10 INSTRUCTION CARD 1

SoundOff-Signal-EA-8-Controller-EVP-Emergency-Vehicle-Fig- (1)

TECHNICAL SPECIFICATIONS

TECHNICAL SPECIFICATIONS
Control Panel Dimensions: 68.8mm H x 96.9mm W x 25.5mm D
Power Module Dimensions: 100.9mm L x 91.8mm W x 26.4mm H
Input Voltage: 10 – 30VDC (negative ground)
Input Current: 45A Max Total Combined
Standby Current: <35mA
Operating Temperature: -40°C to +60°C
Number of Positive Outputs: 8
Number of Negative

Outputs:

2
Max Current/Positive Outputs: 1x 15A, 2x 10A, 1x 10A (for Output 4~8)
Max Current/Negative Outputs: 2x 2A
Fuse Rating: 50A (user-supplied)
Cable Length: 6-pin wire harness: 30cm

RJ45 cable: 4m

Certifications: ECE R10

MOUNTING

Screw Mount Bracket

SoundOff-Signal-EA-8-Controller-EVP-Emergency-Vehicle-Fig- (2)

  1. Choose a desired place for installation.
  2. Use the base as the template to locate and mark two mounting holes on the mounting surface.
  3. Secure the bracket with the two Ø4 self-drilling screws supplied.
  4. Assemble the controller with the bracket by firmly tightening the knurled knob.
  5. Adjust the bracket at an angle most convenient to your operation.

Power Module

SoundOff-Signal-EA-8-Controller-EVP-Emergency-Vehicle-Fig- (3)

  1. Choose a flat surface to install the power module.
  2. Use the power module as the template to locate and mark four mounting holes on the mounting surface.
  3. Secure the power module with the four #8 self-drilling screws supplied.
    NOTE: Always install the power module away from a heat source

Placement of Decals

SoundOff-Signal-EA-8-Controller-EVP-Emergency-Vehicle-Fig- (4)

  1. The controller is shipped without any button decals installed.
  2. After assembling the controller and the mounting bracket, apply a desired decal above each button to facilitate subsequent programming and operation.

WIRING

Power Module

SoundOff-Signal-EA-8-Controller-EVP-Emergency-Vehicle-Fig- (5)

CONTENTS
NO. COMPONENT
1 BLADE TERMINALS
1A POSITIVE OUTPUT 1 (MAX. 15A)
1B POSITIVE OUTPUT 2 (MAX. 10A)
1C POSITIVE OUTPUT 3 (MAX. 10A)
1D POSITIVE OUTPUT 4  

TOTAL CURRENT OF OUTPUT 4~8 IS 10A MAX

1E POSITIVE OUTPUT 5
1F POSITIVE OUTPUT 6
1G POSITIVE OUTPUT 7
1H POSITIVE OUTPUT 8
2 POWER INDICATOR
3 RJ45 CABLE
4 TERMINAL BLOCK
5 6-PIN WIRE HARNESS

6-Pin Wire Harness Pinout

SoundOff-Signal-EA-8-Controller-EVP-Emergency-Vehicle-Fig- (6)

Output Overload & Short Circuit Protection:

  • B1: If the total load current from output 1 exceeds 15A, B1 will turn OFF, Green LED on B1 & 10 Amber TA LEDs will single flash, and Beeper will sound together to show Overload or Short Circuit status. The EA-8 Controller will be locked out and must be RESET to use.
  • B2: If the total load current from output 2 exceeds 10A, B2 will turn OFF, Green LED on B2 & 10 Amber TA LEDs will single flash, and Beeper will sound together to show Overload or Short Circuit status. The EA-8 Controller will be locked out and must be RESET to use.
  • B3: If the total load current from output 2 exceeds 10A, B3 will turn OFF, Green LED on B3 & 10 Amber TA LEDs will single flash, and Beeper will sound together to show Overload or Short Circuit status. The EA-8 Controller will be locked out and must be RESET to use.
  • B4~B8: If combined loads from outputs 4-8 exceed 10A, B4~B8 will turn OFF, Green LED on B4~B8 & 10 Amber TA LEDs will single flash, and Beeper will sound together to show Overload or Short Circuit status. The EA-8 Controller will be locked out and must be RESET to use.
  • B2 & B4 (Negative Outputs): If there is a short circuit on either Negative output 2 or 4, B2 or B4 respectively will turn OFF, Red LED on B2 or B4 & 10 Amber TA LEDs will single flash and Beeper will sound together to show Overload or Short Circuit status. The EA-8 Controller will be locked out and must be RESET to use.

To RESET Overload Status:

Soft Reset:

  1. Press & the HOLD button B4 for 2 seconds to reset.
  2. Fix Overload or short circuit condition on load/s,
  3. Reactivate output to test.

Hard Reset:

  1. Remove Power from the Power Module.
  2. Fix the overload or short circuit condition on the load/s.
  3. Reconnect Power to the Power Module and test all outputs ON at the same time to ensure the overload condition is fixed.

PROGRAMMING AND OPERATION

GENERAL OPERATION FOR PROGRAMMING MODE

Programming Mode 1 and Programming Mode 2

  • EA-8 Controller has two programming modes.
  • Programming Mode 1 allows you to configure B1~B8 and the settings of each input.
  • Programming Mode 2 allows you to configure the Traffic Arrow function, input configuration of Traffic Arrow, Standby Mode, B4 flashing mode under Standby Mode, and Buzzer ON/OFF configuration.
  • You can also reset to the factory default configuration in Programming Mode 2.

Programming Mode 1 and Programming Mode 2

  • Press B1 and B3 for more than 1 second to enter Programming Mode 1 (See page 10).
  • Press B2 and B4 for more than 1 second to enter Programming Mode 2 (See page 16).
    NOTE: The indicator light in the upper right corner will flash in single flash for Mode 1, or double flash for Mode 2.SoundOff-Signal-EA-8-Controller-EVP-Emergency-Vehicle-Fig- (7)

Change Setting Value

  1. Press B1 and B3 for more than 1 second to enter Programming Mode 1.
  2. Press the button you would like to configure. The indicator light at the upper left corner will be lit up to indicate the current setting (1 light = Setting #1, 2 lights = Setting #2… and so on).
  3. Press the button again to go to the next setting. The indicator light will show the current setting according to the rule mentioned above.
  4. Press B1 and B3 for more than 1 second to exit and save your configuration.

Error Signal
Under Programming Mode 1 or Mode 2, when you program a button with a function that cannot be activated (e.g. B1 has been set as a permanent switch. Configure B3 to activate B1 automatically), an error occurs and the green backlight will flash three times on those buttons with three “beep” sounds.

Reset to Factory Default Configuration

  1. Press B2 and B4 for more than 1 second to enter Programming Mode 2.
  2. Press and hold B3 and B4 for more than 5 seconds.
  3. If the EA-8 Controller has been restored to the factory default configuration successfully, the controller will return to operation mode (after “beep” three times and the green backlight is ON).

Automatic Standby Mode (default configuration)
Automatically enter Standby Mode after 15 minutes if no buttons are activated and Input 1 is not activated either (Refer to Programming Mode 2, page 17, for detailed information on Standby Mode Configuration).

NOTE:
After entering Standby Mode, Programming Mode CANNOT be accessed by default. If you want to enter Programming Mode, disconnect all power and reboot your EA-8 Controller.

Testing Mode (for factory users only)

  1. Enter Programming Mode 2.
  2. Press and hold B7 and B8 for more than 3 seconds.
  3. Under Testing Mode, you can test the connection of Input 1 / Input 2 / Input 3 respectively.
  4. After finishing testing, disconnect all power to exit Testing Mode.
    NOTE: Testing Mode is accessible ONLY under Factory Default Configuration.

STANDBY MODE

Enter Standby Mode Automatically (default configuration)
Automatically enter Standby Mode after 15 minutes if no buttons are activated and Input 1 is not activated either.

Enter Standby Mode Manually (default configuration)

  • Manually enter Standby Mode by pressing B4 for more than 1 second.
  • It will turn off all button functions. (Refer to Programming Mode 2, page 17, for detailed information on Standby Mode Configuration)
    NOTE: After entering Standby Mode, Programming Mode CANNOT be accessed by default. If you want to enter Programming Mode, disconnect all power and reboot your EA-8 Controller.SoundOff-Signal-EA-8-Controller-EVP-Emergency-Vehicle-Fig- (8)

DEFAULT CONFIGURATION OF BUTTONS
B1 = POSITIVE OUTPUT 1

ON/OFF Switch

  • Activate B1 will activate the main warning light.
  • When B1 (main warning light) is interlocked by B2 (siren), it is possible to activate B1 by pressing B2.
  • Also, Input 3 can be connected to an external switch to activate B1 (main warning light) and B2 (siren).SoundOff-Signal-EA-8-Controller-EVP-Emergency-Vehicle-Fig- (9)

B2 = POSITIVE OUTPUT 2 & NEGATIVE OUTPUT 1
Siren Interlock w/ Siren Kill

  • Connect Input 2 to the handbrake.
  • Activate B2 will activate the siren.
  • Activate B2 (siren) will also activate B1 (main warning light) simultaneously.
  • When B2 (siren) is activated, turning on Input 2 (handbrake) will deactivate B2 (siren) immediately.

B3 = POSITIVE OUTPUT 3
Grill warning light kill w/o reverting

  • Connect Input 2 to the handbrake.
  • Activate B1 (main warning light) will activate B3 (grill warning light) simultaneously. NOTE: B3 can be activated only when B1 is activated.
  • When B3 is activated, turn on Input 2 (handbrake) will deactivate B3 immediately. NOTE: B3 will not revert when input 2 (handbrake) is off.
  • B4 = POSITIVE OUTPUT 4 & NEGATIVE OUTPUT 2
    ON/OFF Switch
    Activate Positive Output 4 and Negative Output 2.
  • B5 = POSITIVE OUTPUT 5
    ON/OFF Switch
    Activate Positive Output 5.
  • B6 = POSITIVE OUTPUT 6
    ON/OFF Switch
    Activate Positive Output 6.
  • B7 = POSITIVE OUTPUT 7
    ON/OFF Switch
    Activate Positive Output 7.
  • B8 = POSITIVE OUTPUT 8
    ON/OFF Switch
    Activate Positive Output 8.
  • TRAFFIC ARROW INDICATOR LIGHT
    No Function
    NOTE: If you want to configure the Traffic Arrow Indicator Light, refer to Programming Mode 2 (See page 17) to conduct the setting operation.

SCENE 1 AND SCENE 2 CONTROLLED BY B5 AND B6
Scene Button Combo: Scene 1

  • Under Programming Mode 1, you can set B5 as the start button of Scene 1.
  • While B5 is activated, B1, B2, B3, B4 will be activated simultaneously.SoundOff-Signal-EA-8-Controller-EVP-Emergency-Vehicle-Fig- (10)

Scene Button Combo: Scene 2

  • Under Programming Mode 1, you can set B6 as the start button of Scene 2.
  • While B6 is activated, B1, B3, and B4 will be activated simultaneously (B4 can be added or removed in Scene 2 by B4 Setting under Programming Mode 1).SoundOff-Signal-EA-8-Controller-EVP-Emergency-Vehicle-Fig- (11)

PROGRAMMING MODE 1 (FOR SETTING B1~B8 BUTTON FUNCTION)

Setting Example: Programming Mode 1

  • Press B1 and B3 for more than 1 second to enter Programming Mode 1.SoundOff-Signal-EA-8-Controller-EVP-Emergency-Vehicle-Fig- (12)
  • Press B1 once, Setting #2 is currently selected. Press B1 again to go to Setting #3.SoundOff-Signal-EA-8-Controller-EVP-Emergency-Vehicle-Fig- (13)
  • After finishing setting, press B1 and B3 for more than 1 second to exit and save your configuration.SoundOff-Signal-EA-8-Controller-EVP-Emergency-Vehicle-Fig- (14)

B1 Setting (B1 controls Positive Output 1)

  • You can use the B1 button as an ON/OFF switch that activates the main warning light. B1 may be interlocked by B2 (refer to B2 Setting, page 12).
  • When B1 (main warning light) is interlocked by B2 (siren), it is possible to activate B1 by pressing B2.
  • Also, Input 3 can be connected to an external switch to activate B1 (main warning light) and B2 (siren).

Enter Programming Mode 1 and configure B1 Setting as the following table

SoundOff-Signal-EA-8-Controller-EVP-Emergency-Vehicle-Fig- (15)

B2 Setting (B2 controls Positive Output 2 and Negative Output 1)

  • You can use the B2 button as an ON/OFF switch that activates the siren. And B2 may interlock B1, when B1 (main warning light) is interlocked by B2 (siren), it is possible to activate B1 by pressing B2.
  • Also, input 2 can be connected to a handbrake or siren status signal to deactivate B2 (siren) for siren kill.

Enter Programming Mode 1 and configure B2 Setting as the following tableSoundOff-Signal-EA-8-Controller-EVP-Emergency-Vehicle-Fig- (16)

B3 Setting (B3 controls Positive Output 3)
You can use the B3 button as an ON/OFF switch that activates the grill warning light and it can be activated simultaneously when B1 (main warning light) is activated.

Enter Programming Mode 1 and configure B3 Setting as the following table:

SoundOff-Signal-EA-8-Controller-EVP-Emergency-Vehicle-Fig- (17)

B4 Setting (B4 controls Positive Output 4 and Negative Output 2)
You can use the B4 button as a switch that activates auxiliary devices or rear warning lights.

Enter Programming Mode 1 and configure B4 Setting as the following table:

SoundOff-Signal-EA-8-Controller-EVP-Emergency-Vehicle-Fig- (18)

B5 Setting (B5 controls Positive Output 5)
You can use the B5 button as an ON/OFF switch that activates the traffic arrow function (warning/in-out mode). B5 may be set as the start button of Scene 1 to activate the siren and all connected warning lights simultaneously. You can also include B5 in Group 1 or Group 2 to activate the traffic arrow function mutually exclusive.

Enter Programming Mode 1 and configure B5 Setting as the following table:

SoundOff-Signal-EA-8-Controller-EVP-Emergency-Vehicle-Fig- (19)

B6 Setting (B6 controls Positive Output 6)
You can use the B6 button as an ON/OFF switch that activates the traffic arrow function (left-arrow mode). B6 may be set as the start button of Scene 2 to activate all connected warning lights simultaneously. You can also include B6 in Group 1 / Group 2 / Group 3 to activate the traffic arrow function mutually exclusive.

Enter Programming Mode 1 and configure B6 Setting as the following table:

SoundOff-Signal-EA-8-Controller-EVP-Emergency-Vehicle-Fig- (20)

B7 Setting (B7 controls Positive Output 7)
You can use the B7 button as an ON/OFF switch that activates the traffic arrow function (center-out mode). You can also include B7 in Group 1 / Group 2 / Group 3 to activate the traffic arrow function mutually exclusive.

Enter Programming Mode 1 and configure B7 Setting as the following table:

SoundOff-Signal-EA-8-Controller-EVP-Emergency-Vehicle-Fig- (21)

B8 Setting (B8 controls Positive Output 8)
You can use the B8 button as an ON/OFF switch that activates the traffic arrow function (right-arrow mode). You can also include B8 into Group 1 / Group 2 / Group 3 to activate the traffic arrow function mutually exclusive.

Enter Programming Mode 1 and configure B8 Setting as the following table:

SoundOff-Signal-EA-8-Controller-EVP-Emergency-Vehicle-Fig- (22)

PROGRAMMING MODE 2

Setting Example: Programming Mode 2

  • Press B2 and B4 for more than 1 second to enter Programming Mode 2.SoundOff-Signal-EA-8-Controller-EVP-Emergency-Vehicle-Fig- (23)
  • Press B1 once, Setting #2 is currently selected. Press B1 again to go to Setting #3.SoundOff-Signal-EA-8-Controller-EVP-Emergency-Vehicle-Fig- (24)
  • After finishing setting, press B2 and B4 for more than 1 second to exit and save your configuration.SoundOff-Signal-EA-8-Controller-EVP-Emergency-Vehicle-Fig- (25)

Standby Mode Setting, B1
Under Programming Mode 2, you can change the entry conditions of Standby Mode by B1 Setting.

Enter Programming Mode 2 and configure Standby Mode Setting as the following table:

SoundOff-Signal-EA-8-Controller-EVP-Emergency-Vehicle-Fig- (26)

B4 Flash Setting, B2
Under Programming Mode 2, you can change the flash mode of B4 under Standby Mode by B2 Setting.

Enter Programming Mode 2 and configure B4 Flash Setting as the following table:

SoundOff-Signal-EA-8-Controller-EVP-Emergency-Vehicle-Fig- (27)

Buzzer Setting, B3
Under Programming Mode 2, you can change the buzzer configuration by B3 Setting.

Enter Programming Mode 2 and configure the Buzzer Setting as the following table:

SoundOff-Signal-EA-8-Controller-EVP-Emergency-Vehicle-Fig- (28)

Backlight Setting, B4
Under Programming Mode 2, you can change the Backlight mode by B4 Setting.

Enter Programming Mode 2 and configure the Backlight Setting as the following table:

SoundOff-Signal-EA-8-Controller-EVP-Emergency-Vehicle-Fig- (29)

Traffic Arrow Function & Input 2 Setting, B5
Under Programming Mode 2, you can change the configuration of the Traffic Arrow function and Input 2 (handbrake) by B5 Setting.

NOTE:
Setting #2~#4 are available only when B5, B6, B7, B8 are set as Group1 or Group2.

Enter Programming Mode 2 and configure Traffic Arrow Function & Input 2 Setting as the following table:

SoundOff-Signal-EA-8-Controller-EVP-Emergency-Vehicle-Fig- (30)

Traffic Arrow Indicator Setting, B6
Under Programming Mode 2, you can change the configuration of the Traffic Arrow Indicator by B6 Setting.

NOTE:
Setting #2~#4 are available only when B5, B6, B7, B8 are set as Group1 or Group2.

Enter Programming Mode 2 and configure the Traffic Arrow Indicator Setting as the following table:

SoundOff-Signal-EA-8-Controller-EVP-Emergency-Vehicle-Fig- (31)

Reset to Factory Default Configuration, B3 & B4

  • Under Programming Mode 2, you can use B3 and B4 to reset to the factory default configuration.
  • Press B2 and B4 for more than 1 second to enter Programming Mode 2.SoundOff-Signal-EA-8-Controller-EVP-Emergency-Vehicle-Fig- (32)
  • Press and hold B3 and B4 for more than 5 seconds.SoundOff-Signal-EA-8-Controller-EVP-Emergency-Vehicle-Fig- (33)
  • If the EA-8 Controller has been restored to the factory default configuration successfully, the controller will return to operation mode (after “beep” three times and the green backlight is ON).SoundOff-Signal-EA-8-Controller-EVP-Emergency-Vehicle-Fig- (34)

Button Combo: Group 1

  • If the B5, B6, B7, and B8 are configured in Group 1, they are mutually exclusive and only one button can be activated at the same time.
  • B5 controls Positive Output 5.
  • B6 controls Positive Output 6.
  • B7 controls Positive Output 6 and 8.
  • B8 controls Positive Output 8.
    NOTE: Positive Output 7 is permanent positive output.

Button Combo: Group 2

  • If the B5, B6, B7, and B8 are configured in Group 2, they are mutually exclusive and only one button can be activated at the same time.
  • B5 controls Positive Output 5.
  • B6 controls Positive Output 6.
  • B7 controls Positive Output 7.
  • B8 controls Positive Output 8.

Button Combo: Group 3

  • If the B6, B7, and B8 are configured in Group 3, they are mutually exclusive and only one button can be activated at the same time.
  • B6 controls Positive Output 6.
  • B7 controls Positive Output 6, 7, and 8.
  • B8 controls Positive Output 8.

EA-8 DUPLICATOR INSTRUCTIONS
Placement of Duplicator Decals

SoundOff-Signal-EA-8-Controller-EVP-Emergency-Vehicle-Fig- (35)

  1. The duplicator is shipped without any button decals installed.
  2. Apply a “Copy” decal on B8 and a “Paste” decal on B4.

EA-8 Duplicator (ETDUE801) Operating Instructions

  1. Configure an EA-8 System: The user will use the EA-8 Control Panel to configure the EA-8 Power Module from the Instruction Manual. Once the configuration is finished, it is ready to copy. Unplug the EA-8 Control Panel and set it to the side.SoundOff-Signal-EA-8-Controller-EVP-Emergency-Vehicle-Fig- (36)
  2. Copy Configuration: Plug in the EA-8 DUPLICATOR into the RJ45 Jack. Make sure the system is powered and IGN is ON. Press and HOLD B8 for 3 sec. to copy the System configuration. The 10 AMBER LEDs will show progress (moving Left to Right) and B8 will turn Red while copying the configuration. Once complete, there are 2 beeps and Button B5 LED will turn RED to indicate a configuration is loaded. The configuration is copied and you may unplug the EA-8 DUPLICATOR. Then plug the RJ45 cable back into the EA-8 Control Panel and fasten the mount.SoundOff-Signal-EA-8-Controller-EVP-Emergency-Vehicle-Fig- (37)
  3. Paste Configuration: With the previous configuration copied into the EA-8 DUPLICATOR, go to another installation. Unplug the RJ45 Cable from the EA-8 Control Panel and plug in the EA-8 DUPLICATOR. Make sure the system is powered and IGN is ON. Press B4 to paste the configuration into the current installation. The 10 AMBER LEDs will show progress (moving Right to Left) and B4 will turn Red while pasting the configuration. Once complete there are 2 beeps and, B4 LED will return to GRN. Note, that it is expected that the EA-8 system will have the same installation wiring as the one being copied from.SoundOff-Signal-EA-8-Controller-EVP-Emergency-Vehicle-Fig- (38)
  4. Plug System Control Panel back into the system: The configuration is copied and you may unplug the EA-8 DUPLICATOR. Then plug the RJ45 cable back into the EA-8 Control Panel and fasten the mount. This installation is now complete. You may repeat steps 3 & 4 to duplicate this configuration in other installations.SoundOff-Signal-EA-8-Controller-EVP-Emergency-Vehicle-Fig- (39)

WARRANTY & RETURN GOODS PROCEDURE

WARNING MESSAGES – PLEASE READ:

  • WARNING – DRILLING ANY HOLES INTO THE SIREN IS NOT RECOMMENDED! THE RISK OF DAMAGING INTERNAL COMPONENTS AND THE RESULTING FAILURE OF THE SIREN WILL VOID ANY WARRANTY OF THIS PRODUCT.
  • WARNING – CARE MUST BE TAKEN WHEN DRILLING THROUGH THE VEHICLE NOT TO DRILL INTO ANY EXISTING WIRING AND CHECK BOTH SIDES OF THE MOUNTING SERVICE BEFORE DRILLING. DE-BURR ANY HOLES AND REMOVE ANY METAL SHARDS OR REMNANTS. INSTALL GROMMETS INTO ALL WIRE PASSAGE HOLES.
  • WARNING – ROUTE WIRES ONLY IN LOCATIONS THAT ARE NOT SUBJECTED TO POTENTIAL WEAR. MAKE SURE TO AVOID ROUTING WIRES IN THE DEPLOYMENT AREA OF YOUR AIRBAG. REFER TO YOUR VEHICLE OWNER’S MANUAL FOR AIR BAG DEPLOYMENT ZONES.
  • WARNING – ALL CUSTOMER SUPPLIED POWER WIRES CONNECTING TO THE POSITIVE (+) OR NEGATIVE (-) BATTERY TERMINAL OR LOCAL CHASSIS GROUND (-) MUST BE SIZED TO SUPPLY AT LEAST 125% OF THE MAXIMUM CURRENT AND PROPERLY FUSED AT THE POWER SOURCE WITH APPROPRIATELY RATED FUSE.

WARRANTY RETURN PROCESS:
Please scan the QR code or visit https://soundoffsignal.com/support-page/returns/.

SoundOff-Signal-EA-8-Controller-EVP-Emergency-Vehicle-Fig- (40)

Alternatively contact your SoundOff Signal Sales Representative, Customer Services staff, or our Technical Department (800.338.7337) for an RMA #, Return Merchandise Authorization Number.

The following information is required for issuance of the RMA #:

  • Reason for returning the product*
  • Address where the replacement product is to be shipped*
  • Telephone number where you may be reached*
  • SoundOff Signal invoice number on which product was purchased**
  • SoundOff Signal part number and serial number**
  • E-mail address where RMA # should be e-mailed**
  • Fax number where RMA # should be faxed**
    • RMA # will not be given without this information.
    • If available, please provide this information.

SoundOff Signal will NOT accept returns without an RMA #. Each RMA # is good for only one (1) return and will expire (30) days after the date it was issued. Products must be shipped back to SoundOff Signal and the RMA # marked on the outside of the package near the shipping label. Please use the following address on your shipping label:

SoundOff Signal
ATTN: RMA # / Technical Services 3900 Central Parkway Hudsonville, MI 49426

WARRANTY EXCLUSIONS:
Shipping & Handling, labor, and service fees are non-refundable. SoundOff Signal is not liable for any damage due to installation or personal injury as a result of using SoundOff Signal products.

WARRANTY FORFEITURE:
A warranty will not be granted if the Warranty Return Policy & Procedure rules are not strictly followed. Physical damage resulting from customer abuse will void the warranty. Warranty will also be voided if any SoundOff Signal and/or manufacturer serial tags, product stickers, seals, or the like, are removed, altered, or tampered with. Returned product that is damaged by shipping via the RMA # procedure is not the responsibility of SoundOff Signal.

Document effective date on the cover and below supersedes previously dated policies and statements. There are no other warranties, expressed or implied, including, but not limited to, any implied merchantability or fitness for a particular use. SoundOff Signal reserves the right to modify this warranty statement at any time; or to discontinue, modify, or upgrade any products of its manufacture with design improvements without prior notice.

Documents / Resources

SoundOff Signal EA-8 Controller EVP Emergency Vehicle [pdf] Instruction Manual
0000KP, 0724, EA-8 Controller EVP Emergency Vehicle, EA-8, Controller EVP Emergency Vehicle, EVP Emergency Vehicle, Emergency Vehicle, Vehicle

References

Leave a comment

Your email address will not be published. Required fields are marked *