SOLAX POWER X3-PRO G2 Strings Incl DC Inverter
Product Information
Specifications
- Model: X3-PRO G2
- Available Power Options: 8 kW, 10 kW, 12 kW, 15 kW, 17 kW, 20 kW, 25 kW, 30 kW
- Installation Manual Version: 3.0
- Website: www.solaxpower.com
Product Usage Instructions
Before proceeding with the installation and usage of the X3-PRO G2, it is crucial to adhere to the following safety guidelines:
- Always use insulated tools during installation.
- Wear individual protective tools during installation, electrical connection, and maintenance.
- Visit the SolaX website for more safety information.
- Read the installation manual thoroughly.
- Ensure you understand and comply with all related regulations.
- Use the provided QR code or visit the SolaX website for the eManual.
- Ensure the inverter is isolated from mains and PV generation suppliers before operation.
- Avoid touching live parts for at least 5 minutes after disconnection from power sources due to high voltage.
FAQ
- Q: What should I do if I encounter a warning message on the inverter?
- A: If you encounter a warning message on the inverter, refer to the user manual or contact SolaX customer support for assistance.
- Q: Can I install the inverter myself?
- A: It is recommended to hire a professional electrician for the installation of the X3-PRO G2 to ensure safety and proper setup.
Safety
General Notice
- Contents may be periodically updated or revised. SolaX reserves the right to make improvements or changes in the product(s) and the program(s) described in this manual without the prior notice.
- The installation, maintenance and grid-related setting can only be performed by qualified personnel who:
- Are licensed and/or satisfy state and local jurisdiction regulations;
- Have good knowledge of this manual and other related documents.
- Before installing the device, carefully read, fully understand and strictly follow the detailed instruction of the user manual and other related regulations. SolaX shall not be liable for any consequences caused by the violation of the storage, transportation, installation, and operation regulations specified in this document and the user manual.
- Use insulated tools when installing the device. Individual protective tools must be worn during installation, electrical connection and maintenance.
- Please visit the website www.solaxpower.com of SolaX for more information.
Descriptions of Labels
Note: The table is only used for the description of symbols that may be used on the inverter. Please be subject to the actual symbols on the device.
DANGER!
Lethal danger from electrical shock due to the inverter
- Only operate the inverter when it is technically faultless. Otherwise, electric shock or fire may occur.
- Do not open the enclosure in any case without authorization from SolaX.
- Unauthorized opening will void the warranty and cause lethal danger or serious injury due to electric shock.
DANGER!
Lethal danger from electrical shock due to the PV
- When exposed to sunlight, high DC voltage will be generated by PV modules. Death or lethal injuries will occur due to electric shock.
- Never touch the positive or negative pole of PV connecting device. Touching both of them at the same time is prohibited as well.
- Do not ground the positive or negative pole of the PV modules.
- Only qualified personnel can perform the wiring of the PV panels.
WARNING!
Risk of personnel injury or inverter damage
- During operation, do not touch any parts other than DC switch and LCD panel.
- Never connect or disconnect the AC and DC connectors when the inverter is running.
- Turn off the AC and DC power and disconnect them from the inverter, wait for 5 minutes to fully discharge the voltage before attempting any maintenance, cleaning or working on any circuits connected.
- Make sure that the input DC voltage ≤ Maximum DC input voltage of the inverter.
- Overvoltage may cause permanent damage to the inverter, which is NOT covered by the warranty.
CAUTION!
- Keep children away from the inverter.
- Pay attention to the weight of the inverter. Personal injuries may be caused if not handled properly.
NOTICE!
- If an external RCD is required by local regulations, check which type of RCD is required for relevant electric codes. It is recommended to use a Type-A RCD with the value of 300 mA.
- All the product labels and nameplates on the inverter shall be maintained clearly visible.
Packing List
- Refer to the actual delivery for the optional accessories.
Installation Site
Installation Carrier
Installation Angle
Installation Space
Installation Tools
Additionally Required Materials
- AC Cable and Micro-breaker recommended
Mechanical Installation
PE Connection
AC Side Connection
DC Side Connection
- Disassembling the dustproof buckles
- Disassembling the PV cables
Communication Connection
Pin Definition
- Pin Definition for DRM (For AU / NZ)/Heat Pump Controller/Remote Shutdown
- For DRM, only DRM 0 is available now.
- Pin Definition for RS485/Meter
Connection Method
Note: Connect the COM port and the RS485 port respectively or simultaneously according to the actual application scene.
- Possible scene 1: COM port connection only
- Possible scene 2: RS485 port connection only
- Possible scene 3: COM port and RS485 port connections simultaneously
Monitoring Connection
Power on the System
Lockable DC Switch
There are two kinds of DC switches for the series inverters:
- Unlockable DC switch (without lock);
- Lockable DC switch (with lock).
- States of the lockable DC switch:
For the lockable DC switch, there are 3 states: ON, OFF and OFF+Lock and the default state is OFF.
- Operation of the lockable DC switch
LCD Panel
- In the normal state, the “Power” / “Pgrid” / “Today” / “Total” information will be displayed respectively. You can press the keys to switch information.
- In the error state, the fault message will be displayed, please refer to the corresponding solutions in the user manual.
General Setting
- The initial password is 2014 which should be changed for the consideration of account security.
Wi-Fi Configuration
Technical Data
DC input
- Max. MPPT power limit per MPPT” means the maximum PV production when using one of the MPPTs only.
AC output
- 9999 for AS/NZS 4777.2
- 14999 for AS/NZS 4777.2
- 14999 for AS/NZS 4777.2
- 29999 for AS/NZS 4777.2
- 29999 for AS/NZS 4777.2, 33000 for PEA
- 47.8 for PEA
If there are two data for this parameter, each data corresponds to the corresponding voltage.
Efficiency, safety and protection
General data
Contact Information
UNITED KINGDOM
- Unit C-D Riversdale House, Riversdale
- Road, Atherstone, CV9 1FA
- +44 (0) 2476 586 998
- service.uk@solaxpower.com
TURKEY
- Fevzi Çakmak mah. aslım cd. no 88 A
- Karatay / Konya / Türkiye
- +90 530 252 02 19
- service.tr@solaxpower.com
USA
- 3780 Kilroy Airport Way, Suite 200, Long
- Beach, CA, US 90806
- +1 (408) 690 9464
- info@solaxpower.com
POLAND
- WARSAW AL. JANA P. II 27. POST
- +48 662 430 292
- service.pl@solaxpower.com
ITALY
- +39 011 19800998
- support@solaxpower.it
PAKISTAN
AUSTRALIA
- 21 Nicholas Dr, Dandenong South VIC 3175
- +61 1300 476 529
- service@solaxpower.com
GERMANY
- Am Tullnaupark 8, 90402 Nürnberg, Germany
- +49 (0) 6142 4091 664
- service.eu@solaxpower.com
- service.dach@solaxpower.com
NETHERLANDS
- Twekkeler-Es 15 7547 ST Enschede
- +31 (0) 8527 37932
- service.eu@solaxpower.com
- service.bnl@solaxpower.com
SPAIN
- +34 9373 79607
- tecnico@solaxpower.com
BRAZIL
- +55 (34) 9667 0319
- info@solaxpower.com
SOUTH AFRICA
Warranty Registration Form
For Customer (Compulsory)
For Installer
- Please visit our warranty website: https://www.solaxcloud.com/#/warranty or use your mobile phone to scan the QR code to complete the online warranty registration.
- For more detailed warranty terms, please visit SolaX official website: www.solaxpower.com to check it.
CONTACT
SolaX Power Network Technology (Zhejiang) Co., Ltd.
- Add.: No. 288, Shizhu Road, Tonglu Economic Development Zone,
- Tonglu City, Zhejiang Province, 310000 P. R. CHINA
- Tel.: +86 (0) 571 5626 0011
- E-mail: info@solaxpower.com
Copyright © SolaX Power Network Technology (Zhejiang) Co., Ltd. All rights reserved.
Documents / Resources
![]() |
SOLAX POWER X3-PRO G2 Strings Incl DC Inverter [pdf] Installation Guide 8 kW, 10 kW, 12 kW, 15 kW, 17 kW, 20 kW, 25 kW, 30 kW, X3-PRO G2 Strings Incl DC Inverter, X3-PRO G2, Strings Incl DC Inverter, Incl DC Inverter, DC Inverter, Inverter |