solaredge P750 Power Optimizer logo

solaredge P750 Power Optimizer

solaredge P750 Power Optimizer product

PV power optimization at the module level

The most cost-effective solution for commercial and large field installations

  • Specifically designed to work with SolarEdge inverters
  • Up to 25% more energy
  • Superior efficiency (99.5%)
  • Balance of System cost reduction; 50% less cables, fuses and combiner boxes, over 2x longer string lengths possible
  • Fast installation with a single bolt
  • Advanced maintenance with module-level monitoring
  • Support high input current, bifacial and high power modules
Power Optimizer Model (Typical Module Compatibility) P750
(for 1 x high power PV module)
UNITS
INPUT
Rated Input DC Power(1) 750 W
Connection Method Single input
Absolute Maximum Input Voltage (Voc at lowest temperature) 60 Vdc
MPPT Operating Range 12.5 – 60 Vdc
Maximum Short Circuit Current per Input (Isc) 20 Adc
Maximum Efficiency 99.5 %
Weighted Efficiency 98.6 %
Overvoltage Category II
OUTPUT DURING OPERATION (POWER OPTIMIZER CONNECTED TO OPERATING SOLAREDGE INVERTER)
Maximum Output Current 18 Adc
Maximum Output Voltage 80 Vdc
OUTPUT DURING STANDBY (POWER OPTIMIZER DISCONNECTED FROM SOLAREDGE INVERTER OR SOLAREDGE INVERTER OFF)
Safety Output Voltage per Power Optimizer 1 ± 0.1 Vdc
STANDARD COMPLIANCE
EMC FCC Part 15 Class B, IEC61000-6-2, IEC61000-6-3
Safety IEC62109-1 (class II safety)
RoHS Yes
Fire Safety VDE-AR-E 2100-712:2013-05
INSTALLATION SPECIFICATIONS
Compatible SolarEdge Inverters Three phase inverters SE16K & larger
Maximum Allowed System Voltage 1000 Vdc
Dimensions (W x L x H) 129 x 169 x 59 mm
Weight 1340 gr
Input Connector MC4(2)
Input Wire Length 1.4 m
Output Connector MC4
Output Wire Length Portrait Orientation: 1.4 m
Operating Temperature Range(3) -40 to +85 ˚C
Protection Rating IP68 / NEMA6P
Relative Humidity 0 – 100 %
  1.  Rated power of the module at STC will not exceed the power optimizer “Rated Input DC Power”. Modules with up to +5% power tolerance are allowed
  2.  For other connector types please contact SolarEdge
  3.  For ambient temperature above +70˚C / +158˚F power de-rating is applied. Refer to Power Optimizers Temperature De-Rating Technical Note for more details
    PV System Design Using a SolarEdge
    Inverter(4)(5)(6)
    230/400V Grid SE16K, SE17K 230/400V Grid SE25K 230/400V Grid SE27.6K* 230/400V Grid SE30K* 230/400V Grid SE33.3K* 277/480V Grid SE40K*
    Compatible Power Optimizers P750
    Minimum String Length Power Optimizers 14 14 14 15 14 14
    PV Modules 14 14 14 15 14 14
    Maximum String Length Power Optimizers 30 30 30 30 30 30
    PV Modules 30 30 30 30 30 30
    Maximum Continuous Power per String 13500 13500 13950 15300 13500 15300 W
    Maximum Allowed Connected Power per String(6) (Permitted only when the difference in connected power between strings is 2000W or less) 1 string – 15750 1 string – 15750 1 string – 15750 1 string – 17550 2 strings or less
    – 15750
    2 strings or less
    – 17550
     

    W

    2 strings or more
    – 18500
    2 strings or more
    – 18500
    2 strings or more
    – 18500
    2 strings or more
    – 20300
    3 strings or more
    – 18500
    3 strings or more
    – 20300
    Parallel Strings of Different Lengths or Orientations Yes

    The same rules apply for Synergy units of equivalent power ratings, that are part of the modular Synergy Technology inverter

  4. P750 can be mixed in one string only with P750
  5.  For SE16K and above, the minimum STC DC connected power should be 11KW
  6. To connect more STC power per string, design your project using SolarEdge Designer
  7. It is not allowed to mix S-series and P-series power optimizers in new installations

© SolarEdge Technologies Ltd. All rights reserved. SOLAREDGE, the SolarEdge logo, OPTIMIZED BY SOLAREDGE are trademarks or registered trademarks of SolarEdge Technologies, Ltd. All other trademarks mentioned herein are trademarks of their respective owners. Date: 6/1/2022 DS-000127-ENG. Subject to change without notice.

Documents / Resources

solaredge P750 Power Optimizer [pdf] Instructions
P750 Power Optimizer, P750, Power Optimizer, Optimizer

References

Leave a comment

Your email address will not be published. Required fields are marked *