ZEBRA SE5800 Mobile Terminal
Specifications
- Model: MC9401
- Brand: Zebra
- Regulatory Compliance: FCC, ISED, 21 CFR1040.10, 1040.11, IEC/EN 60825-1:2014
- LED: Yes
- Country of Origin: Netherlands
- RF Compliance: Part 15 of FCC Rules
- RF Exposure Requirements: FCC and ISED
- Hazardous Locations Warning
Feature | SE4770 | SE5800 |
---|---|---|
Wavelength | 630-680 nm | 500-570 nm |
Beam Diameter | 1.5 mm | 2.5 mm |
Beam Divergence | 12.5 mrad | 4 mrad |
Scanning Angle | 42.7° | 42° |
Weight | 16.9 g | 16.7 g |
Compliance with 21 CFR1040.10 and 1040.11 except for deviations pursuant to Laser Notice No. 56, dated May 08, 2019, and IEC/EN 60825-1:2014.
Product Usage Instructions
Regulatory Compliance:
Ensure that the device complies with FCC and ISED regulations. Refer to zebra.com/doc for detailed regulatory information.
LED Usage:
The device features LED indicators for status notifications. Refer to the user manual for LED indications and their meanings.
RF Compliance:
Operate the device within the specified RF exposure requirements outlined by FCC and ISED to ensure compliance.
Hazardous Locations:
Avoid using the docking port in hazardous locations. Follow proper battery replacement procedures to prevent explosion hazards.
Support and Warranty Information:
For support, warranty, and product information, visit zebra.com/support and zebra.com/warranty. Contact entitlementservices@zebra.com for further assistance.
LED Safety
This device includes LEDs that comply with IEC 62471:2006 and EN 62471:2008 standards.
Battery and Charging Safety
Use only the battery model BT-000370 for this device, and follow proper disposal instructions for batteries.
For more information on battery safety and best practices, please visit zebra.com/battery/documentation.
European Union Regulatory Information
In compliance with the European Economic Area (EEA) regulatory standards, Zebra Technologies provides a Declaration of Conformity (DoC), which can be found at zebra.com/doc.
Regulatory Information for MC9401
This document provides regulatory, safety, and environmental information for the MC9401 device by Zebra Technologies Corporation.
Local Language Translation Notice
Local language translation of this document is available. For details on how to obtain a localized version, please visit zebra.com/support.
Operating Temperature
The device is designed to operate within a temperature range of 0°C to 50°C.
Radio Frequency Interference Notice
This device complies with Part 15 of the FCC Rules and must accept any interference received, including interference that may cause undesired operation.
RF Exposure Requirements – FCC and ISED
This device must be used with a minimum separation distance of 1 cm from the user’s body and nearby persons, and specific RF exposure requirements apply in hotspot and mobile device modes.
Hazardous Locations Information
This device is suitable for use in specified hazardous locations only. Ensure that power is switched off and the area is non-hazardous before changing the battery or disconnecting equipment.
Waste Electrical and Electronic Equipment Directive (WEEE)
For proper disposal and recycling information, please visit zebra.com/weee.
Additional Resources
For further assistance and information, including technical support and product warranty, visit zebra.com/support.
Zebra Support Community knowledge base can provide additional help at supportcommunity.zebra.com/s/knowledge-base.
Global Contact Information
For questions or concerns regarding Zebra products, visit zebra.com/contact.
Disclaimer
This transcription is provided for informational purposes only. Zebra Technologies Corporation is not responsible for any errors or omissions in the content. For the most accurate and up-to-date information, consult the original documents or visit Zebra’s official website.
Frequently Asked Questions (FAQ)
What should I do if the LED indicators are not functioning?
If the LED indicators are not working properly, check the device manual for troubleshooting steps. Contact customer support if issues persist.
How can I ensure RF compliance while using the device?
To comply with RF exposure requirements, maintain a distance of at least 20 cm between the device’s antenna and other transmitters unless approved otherwise.
How do I obtain a local language version of the regulatory document?
Visit zebra.com/support for instructions on obtaining localized documents.
Where can I find safety information for the battery used in MC9401?
Battery safety information can be accessed at zebra.com/battery/documentation.
What are the RF Exposure requirements for the MC9401?
The device must be used with at least 1 cm separation from the body, as detailed in the RF Exposure section.
Where can I find the Declaration of Conformity for the European Economic Area?
The Declaration of Conformity is available at zebra.com/doc.
Documents / Resources
![]() |
ZEBRA SE5800 Mobile Terminal [pdf] Instructions SE5800 Mobile Terminal, SE5800, Mobile Terminal, Terminal |