PARAMETERS
pH | Range | 0.1~14.0 pH |
Resolution | 0.1 pH | |
Accuracy | ± 0.1 pH | |
CL | Range | 0.1~4.0 mg/L |
Resolution | 0.1 mg/L | |
EC | Range | 0~1999uS/cm, 2000~10000uS/cm |
10.01~20.00mS/cm | ||
Resolution | 1µS/cm; 10µS/cm; 0.01mS/cm | |
Accuracy | ±2% F.S | |
Salt | Range | 0~999ppm; 1000~9990ppm |
Resolution | 1ppm; 10ppm | |
Accuracy | ±2% F.S. | |
ORP | Range | -1200mV~ +1200mV |
Resolution | 1mV | |
Accuracy | ±15 mV | |
Temp. | Range | 0.0°C~60.0°C ; 32.0°F~140.0°F |
Resolution | 0.1°C; 0.1°F | |
Accuracy | ±0.5°C | |
Calibration | pH | 6.8/4.0/9.1 or 7.0/4.0/10.0 |
(Optional two sets of calibration modes) | ||
ORP | 256 mV | |
EC/SALT | 1413uS/cm; 12.88 mS/cm | |
Calibration records can be viewed | ||
ATC Temp. | 0.1°C~60.0°C | |
Environment | 0.1°C~60.0°C, RH: max 90% | |
EC Temp. Compensation | 0.1~3.0%/°C (Factory Default 2.0%/°C) | |
Bluetooth | mobile bluetooth 5.2 Version | |
Backlights | with backlights, support mobile control | |
Data | Save | save as Excel sheet |
Printing | support | |
Waterproof | IP67 | |
Battery | 3*AAA battery low battery indicator | |
Standby time | around one year | |
Data storage | can store the latest 1000 records or data | |
Dimensions/Weight | Height: 155mm; Diameter: 85mm (6.1*3.35 in) / 210g |
OPERATION
Click
switch between Chinese and English.
- Turn on the meter by pressing
- Put the electrode into the testing solution, Wait until the testing is stabilized.
- Press
button to convert pH, SALT, EC, CL, ORP Mode.
- Press
to HOLD the testing.
- Long press
button to convert temperature between °C and °F.
Bluetooth Function:
- Long press
, will display on the screen. Open the APP, APP will match the meter model automatically.
- Press
in APP, All testing results (mV/mg/L/ppm/pH/uS/cm/°C/°F) can be viewed on the APP. Model number display on the top of screen.
- Press
Back light on Back light off
- Power display
- H is displayed on the screen
- Click to save data Manually
Click
: save measurement data.
- Automatically save data
Auto Saved time interval can be set (between 30~9999 seconds).
Pressto view measurement data.
- Set pH/EC/ORP/CL Max or Min Limit values according to user’s requirement. If testing results are out of range, the digits will display in red.
- Set EC Temperature compensation Factor: Factory default: 2.0 %/°C;
The EC Temp. factor of 0.1~3.0%/°C can be set. - Save/Share and Print
- Press
to view records.
- Press
to share the file.
If connect to the printer, the testing records can be printed.
- Press
- Standby
Disconnect APP. If there is no operation for five minutes, the instrument will automatically enter the standby state and the screen display will turn black. All functions work normally in standby mode.
When the bluetootn is connected the instrument will not enter the standby state In standby state, the instrument can store Up to 1000 sets of data Open App data will be automatically transferred.
VIEW MORE
Press and VIEW MORE… can find more different models.
PH CALIBRATION
6.8/4.0/9.1 Calibration
pH Solution: Dissolve each buffer solution into 3 cups which is filled with 250mi distilled water. Convert to pH mode.
- Put electrode into 6.86 solution;
Wait until the testing is stabilized; Pressfor 5 seconds, release button; Wait for 6.8 to flash 3 times; Finished 6.8 calibration;
Clean electrode with distilled water. - Put electrode into 4.00 solution;
Wait until the testing is stabilized; Pressfor 5 seconds, release button; Wait for 4.0 to flash 3 times; Finished 4.0 calibration;
Clean electrode with distilled water. - Put electrode into 9.18 solution;
Wait until the testing is stabilized; Pressfor 5 seconds, release button; Wait for 9.1 to flash 3 times; Finished 9.1 calibration;
Clean electrode with distilled water.
7.0/4.0/10.0 are the same calibration steps.
There has two sets calibration points: 6.8/4.0/9.1 or 7.0/4.0/10.0
It can be chosen in
Press
can view calibration records.
ORP CALIBRATION
256mV Calibration
- Press
button, convert to ORP Mode;
- Put the electrode in the 256mV solution; Wait for the value to stabilize;
- Press
for 5 seconds and release button;
- Press up arrow
to add digits; Press down
arrow to reduce digits until the showing digit is 256
- Release button; Wait for 256 to flash 3 times;
- Finished ORP calibration.
- Clean electrode with distilled water.
EC/SALT CALIBRATION
1413uS/cm Calibration
- Press ,
convert to EC Mode.
- Put electrode into 1413uS/cm standard solution, wait until the testing is stabilized, press
for 5 seconds, screen displays the testing values. Press up arrow
to add digits. Press down arrow
to reduce digits until the showing digit is 1413. Release button.
- 1413 flashes 3 times, finished 1413 calibration.
Clean electrode with distilled water.
12.88mS/cm Calibration
- Press
, convert to EC Mode.
- Put electrode into 12.88mS/cm standard solution, wait until the testing is stabilized; Press
for 5 seconds, screen displays the testing values. Press up arrow
to add digits. Press down arrow to reduce digits until the showing digit is 12.88.
- Release button. 12.88 flashes 3 times, finished 12.88 calibration.
- Clean electrode with distilled water.
Please choose a standard solution which is close to your test solution for EC calibration.
ATTENTION
- When the battery is low, please replace the battery as below:
Unscrew the top cap clockwise direction and replace 3 AAA battery.
Then use the plastic wrench to tighten the battery cap.Note: The cap must be tightened, otherwise the meter is immersed in water, the meter can’t use anymore.
- Standard value of content in swimming pool: pH: 6.5~8.0pH ; Chlorine: 0.3~0.5mg/L ORP: +650~+750mV; TDS: 2700~3400ppm
When the pH <6.5pH, chlorine value is “– ” That means the pool water needs to be treated.
APPLICATION FIELD
WARRANTY
- Meter warranty time: 12 months
- Electrode warranty time: 6 months
- During the warranty period, the meter will be repaired or replaced free of charge due to damage caused by the meter quality.
The following are not covered by the warranty:
- Damaged by wrong use or self-assembly.
- Damaged by the human factors.
- Damaged by force majeure.
Frequently Asked Questions
How do I calibrate the pH of the device?
To calibrate pH, dissolve each buffer solution into cups filled with distilled water, switch to pH mode, and follow on-screen instructions for calibration.
What is the standby time of the device?
The device has a standby time of around one year when using 3 AAA batteries.
Documents / Resources
![]() |
YINMIK WQM-369 Bluetooth 6 In 1 Floating Pool Monitor [pdf] Instruction Manual WQM-369 Bluetooth 6 In 1 Floating Pool Monitor, WQM-369, Bluetooth 6 In 1 Floating Pool Monitor, 6 In 1 Floating Pool Monitor, Floating Pool Monitor, Pool Monitor, Monitor |