Starline F66
Product Information Sheet
General Information
- A qualified electrician, in accordance with IET wiring regulations should carry out connection to mains wiring.
- Luminaire must be isolated before commencing any necessary maintenance work or battery connection.
- Ensure that the rated voltage and frequency requirements are compatible with the available mains supply.
- Do not carry out high voltage insulation test, i.e. 500/1000v this may damage internal components.
- The light source contained in the luminaire shall only be replaced by the manufacturer or a designated service agent or a suitably qualified person.
- Batteries must only be replaced by a qualified electrician once they fail to meet the required duration.
- Dali control cables must be double insulated & have an equivalent rating to the supply cable if applicable.
- Ensure ceiling is of sufficient strength to support luminaire – Fit secondary suspension where necessary.
- Observe ESD precautions during installation.
- All luminaires must be EARTHED. (Excluding Class II luminaires).
- Do not cover recessed luminaires with any thermally insulating materials.
- Do not use the wire suspension to raise or lower the luminaire. (See full instructions for further details.)
Product Specification
Lumen outputs & wattages | 1030 Lumen per meter (9W), 1690 Lumen per meter (15.5W) |
LEDs per meter | 140 |
Beam Angle | 120° |
Weight | 278g |
Nominal voltage | 24V |
Connection | 1.5mm2 input |
Ingress Protection | IP54/1P66 |
Colour temperature | 2700K, 3000K, 4000K |
Temperature Range | -25°c to +50°c |
Full Installation Instructions
Product Dimensions
2 person install
054571 – REV 4 – 01/11/23
Whitecroft Lighting Limited
Burlington Street,
Ashton-under-Lyne,
Lancashire OL7 0AX
Technical Support
0161 330 6811
technical@whitecroftlight.com
http://www.whitecroftlighting.com
SF66CON1
1
2a 70LEDs/m
2b 140LEDs/m
3
4
IP54
IP66
5
6
7
IP66/IP54
1
2
3
Aluminium Housing
Installation notes:
For aluminium housing, we recommend 3 x clips per metre, or every 30cm.
For aluminium housing, drill a hole in the plastic endcap for cable exit.
Drivers:
Code | Watts | Max number of 9W tape reels* | Max number of 15.5W tape reels* |
CNSLD20 | 20 | 1 (max 2m) | 1 (max 1m) |
CNSLD100 | 100 | 2 | 1 |
CNSLD250-IP20 | 250 | 4 | 2 |
CSFDY80 | 80 | 1 | 1 (max 3m) |
CSFDY150 | 150 | 2 | 1 |
• Note: Recommended maximum number of drivers, includes 20% reslience
CNSLD20
OT 20/220-240/24
CNSLD100, CNSLD250-1P20
CSFDY80
CSFDY150
Documents / Resources
![]() |