UniPOS 7000M Addressable Modular System Panel Owner’s Manual
The Addressable Modular System Panel 7000M is designed to satisfy a professional solution enhancing:
- Installation procedure with set-up flexibility
- 2-10 loop capability
- Supplied with 2 loops as standard
- Add up to 4 more loop module cards to increase panel capacity to a maximum of 10 loops
- Certified to EN54-2/4/13
Product is also available with a printer – Part Number: 7000M-P
Technical Features
Number of Loop Addressable Devices per Loop | up to 210 pcs |
Number of Loop Addressable Devices per Panel | up to 2,100 pcs |
Number of Loop Modules per Panel | up to 5 (total 10 loops) |
Number of Loop Modules per System | up to 64 |
Number of BIO Modules | up to 5 per panel |
Number of Addressable Devices per System | up to 13,440 p c s |
Detection Zone | contain up to 32 loop detectors, fire inputs or/and manual call points |
Detection Zones per Panel / System | up to 1,023 / 30 per loop |
Configurable Week Schedule (Day / Night Mode) | sensitivity and logic change to detectors, delays change in alarm zones |
Protection Zones per Panel / System | up to 1,023 / 30 per loop |
Protection Zones peí Panel / System | up to 1,023 / 30 per loop |
Protection Zones per Panel / System | redundant CAN network supports up to 16 panels and up to 13,440 detectors |
Maximum Number of Addressable and Conventional Fire Alarm Devices | up to 35 per loop, up to 350 per panel connected to the loops – conventional and addressable devices (sounders) |
Dependencies on more than one alarm signal | CI Mode B (detecting fire by two zones activation) CI Mode C (detecting fire with inspection time) |
Alarm Counter | up to 9,999 (can be deleted by script at level access 4) |
Event Log (archive) | 10,000 events |
Configurable Output to Fire Protection Equipment (addressable output device) |
LED indication for activation |
input for the reception of a confirmatory signal from fire protection equipment, indicated by means of separate indicator | |
Other Features |
alarm zones and protection zones can be activated from any detection Zones (one detection zone cannot activate two alarm zones) |
configurable sounder melodies in alarm and prealarm state (Warning-state) for every Alarm zone. | |
output to fire alarm devices | |
alarm confirmation input from fire alarm routing equipment | |
fault monitoring fire protection equipment (in/out) | |
delay to outputs, day / night mode | |
fault signals from points |
|
total loss of power supply |
|
output to fault warning routing equipment |
|
disablement of addressable points |