FB2ULU USER’S MANUAL
FB2ULU IoT Sensor and Controller
FB2ULU is a versatile integrated IoT sensor and actuator driver PCBA with built-in sub 1Ghz transceiver supports Lora communication, it can be programmed to respond to temperature sensor and UART wired communication, for automated actuation for wide voltage range DC electric actuators such as water pump, solenoid locking device, or pneumatic device.
The compact size makes FB2ULU an ideal solution to retrofit with IoT device with small enclosure.
Specification
RF: Single channel Lora at 923.303Mh,z or 919.303Mhz max TX power: 4.0dBm
Power consumption DC 3-3.6V 150mA max
1 x UART communication
2 x NTC thermistor input
1 x MOSFET solid state DC switch max 3A, supported input voltage from 6-24V DC
FCC Warnning:
This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, maycause harmful interference to radio communications. However, there is no guarantee thatinterference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
- Reorient or relocate the receiving antenna.
- Increase the separation between the equipment and receiver.
- Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
- Consult the dealer or an experienced radio/TV technician for help.
Caution: Any changes or modifications to this device not explicitly approved by manufacturer could void your authority to operate this equipment.
This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1)This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with minimum distance 0cm between the radiator and your body.